Laserfiche WebLink
ELEi _ - <br />200Se4 <br />Q <br />O <br />00 <br />M <br />N <br />0 <br />N <br />N <br />O <br />N <br />4E <br />i <br />I <br />OFFICE OFFIC; <br />S223 S2%, <br />I <br />i <br />cn <br />57< <br />w; <br />I <br />I <br />I <br />COP`( / Pf,;; <br />S220 r <br />i <br />OFFICE <br />S218 <br />LJ ,\ <br />EXIS � <br />CORRIDOR <br />5 S200C4 <br />I <br />I I <br />M <br />a OFFICE <br />S216 <br />L� <br />5 � <br />F�ql 1 <br />5E 6E <br />---- IT-- <br />%J <br />7E 90E <br />— E <br />OFF'"' OFFICE <br />,r S228 <br />I <br />°a <br />i ii F <br />mrnrnuw..•.... masm�v.... <br />I I <br />CORRIDOR. <br />S20005 <br />I <br />� I <br />ii <br />I <br />OFFICE <br />S237 <br />}2100,, H I .A <br />I <br />HALL <br />S-400H I <br />AUDIOLOGY BOOTH <br />S238 <br />CORRIDOR <br />S200C3 <br />I I I I <br />VVK AREA 'I`JK Af-IIrA <br />S204A S203A <br />I I <br />! <br />I I I <br />CLASS CLASS <br />S204 20 CLAS ». <br />S20` , <br />I <br />CORK <br />S200C2 <br />I I <br />I <br />I I I I <br />ORIDC <br />KIT f VENILI <br />S20f S206A <br />I <br />SHWH I 1 <br />S210I <br />�;{AM <br />�264 <br />I <br />i <br />I I -- <br />I Es <br />OFFI aF T ILF I- <br />s <br />S26r 2 i� <br />I W K S TA m <br />S271 <br />I <br />"V K S A <br />S275B <br />t <br />I <br />I <br />"JK STA <br />j27::✓l�i <br />I <br />I <br />I <br />REC FP f_I `N <br />S2611 Ij <br />FLOOR PLAN - LEVEL 2 - AREA E <br />1/4" = 1 '-0" <br />I <br />)RRIDOR I <br />3,20006 ---- -- <br />I <br />I <br />S <br />ELECI <br />S20006 <br />I <br />CORRIDOR <br />200C1A <br />I <br />O <br />*011111111 <br />GENERAL NOTES <br />G O S <br />KAISER <br />11i <br />r <br />PERMANENTE��: <br />13HESE DRAWINGS INDICATE IN GENERAL THE PROJECT IN TERMS OF <br />ARCHITECTURAL DESIGN INTENT, THE DIMENSIONS OF THE BUILDING, THE MAJOR <br />Project <br />ARCHITECTURAL ELEMENTS AND TYPE OF STRUCTURAL, MECHANICAL AND <br />ELECTRICAL SYSTEMS. THE DRAWINGS DO NOT NECESSARILY INDICATE OR <br />Kaiser Permanente Everett <br />DESCRIBE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF <br />THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. AS INDICATED OR <br />MOB Backfil <br />DESCRIBED, THE CONTRACTOR SHALL FURNISH ALL ITEMS REQUIRED FOR THE <br />PROPER EXECUTION AND COMPLETION OF THE WORK. <br />2929 PINE STREET <br />2. CONTRACTOR TO VERIFY ALL WALL AND DOOR FIRE RATINGS.A FINISH OR FIRE <br />EVERETT, WA 98201 <br />RATING INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH OF WALL IS TO <br />BE FINISHED OR FIRE RATED. CONTRACTOR TO MAINTAIN THE REQUIRED FIRE <br />RATING CONTINUITY OF THE FLOOR / WALL CONSTRUCTION. <br />Prepared for <br />3. ALL PARTITIONS ARE DIMENSIONED TO FACE OF PARTITION TYPE AS INIDICATED, <br />KAISER FOUNDATION <br />UON. ALL DIMENSIONS MARKED "CLEAR" OR "CLR" SHALL BE MAINTAINED AND <br />ALLOW FOR THICKNESS OF ALL WALL FINISHES. DIMENSIONS NOTED "CLEAR" OR <br />HEALTH PLAN, INC. <br />"CLR" MUST BE ACCURATELY MAINTAINED AND SHALL NOT VARY MORE THAN +/- <br />1/8" WITHOUT WRITTEN CONSENT FROM THE ARCHITECT. <br />NATIONAL FACILITIES SERVICES <br />4. ALL GYP BD PARTITIONS SHALL BE TAPED, SPACKLED AND SANDED WITH NO <br />POST OFFICE BOX 12916 <br />VISIBLE JOINTS. PATCH AND REPAIR SURFACES TO MATCH ADJACENT OR <br />OAKLAND, CA 94604 <br />ADJOINING SURFACES WHERE REQUIRED. ALL SURFACES SHALL BE ALIGNED. <br />5.WHERE FURRED PARTITIONS EXCEED MAXIMUM HEIGHT, BRACE TO ADJACENT <br />STRUCTURE, PER DETAIL. <br />6.FIRE SAFE PENETRATIONS AT RATED PARTITIONS PER APPLICABLE UL <br />ASSEMBLY. <br />TALL INTERIOR PARTITION, PENETRATIONS, OTHER OPENINGS IN THE BUILDING <br />SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED. <br />8. PROVIDE METAL STUD BRACKETS AS DETAILED AT LOCATIONS INCLUDING BUT <br />NOT LIMITED TO: GRAB BARS, SHELVING, OVERHEAD CABINETS, SIGNAGE, TOILET <br />ROOM ACCESSORIES, ETC <br />, <br />8.ALL BACKING IN PARTITIONS, CEILINGS AND SOFFITS FOR THE INSTALLATION OF <br />MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, SECURITY, LOW <br />VOLTAGE, AND AUDIO/VISUAL EQUIPMENT TO BE COORDINATED AND INSTALLED BY <br />THE RESPECTIVE CONTRACTOR PRIOR TO INSTALLATION OF GYP BOARD OR <br />PLASTER FINISH MATERIAL. DRYWALL EXPANSION ANCHORS ARE NOT TO BE USED <br />TO MOUNT ANY TYPE OF EQUIPMENT. <br />10.ALL WOOD TO BE FIRE RETARDANT TREATED IN ACCORDANCE WITH LOCAL <br />Hellmuth, Obata & Kassabaum, Inc. <br />CODES. <br />1218 Third Avenue, Suite 500 <br />Seattle, WA 98101 USA <br />11.ALL SIGNAGE IS NIC, LION. <br />t +1 206 493 1771 f +1 206 493 1778 <br />12.ALL GYP BD PARTITIONS RECEIVING RUBBER BASE TO BE FINISHED SMOOTH TO <br />THE SLAB. <br />All reproduction & intellectual property rights reserved <br />2022 <br />13.PATCH AND REPAIR EXISTING SLAB WITH POLYMER MODIFIED GROUT <br />In Association with <br />MANUFACTURED BY MASTER BUILDERS, EMACO OR EQUAL FOR NEW FLOOR <br />FINISHES. <br />Mortenson <br />14.PATCH AND REPAIR EXISTING WALLS IN PREPARATION FOR NEW WALL FINISHES. <br />General Contractor <br />10230 NE Points Drive, Suite 300 <br />15.ALL CASEWORK. TO BE PREMIUM GRADE OR BETTER AS DEFINED BY THE <br />Kirkland, WA 98033 <br />ARCHITECTURAL WOOD INSTITUTE OR WIC. <br />16. LOCATE ALL DOOR OPENINGS 4" FROM ADJACENT WALLS, LION <br />FLOOR PLAN --LEGEND <br />(E) ROOM OR ZONE TO REMAIN, NOT INCLUDED IN <br />THIS SCOPE OF WORK <br />(E) GYP BD PARTITION TO REMAIN <br />NEW GYP BD PARTITION AS INDICATED <br />NEW CASEWORK/ MILLWORK B.O.; COORDINATE <br />WITH POWER & DATA PLAN <br />NEW GLAZED OPENING WITH ALUM OR HM FRAME AS <br />INDICATED <br />DOOR OPENING NUMBER, SEE DOOR SCHEDULE <br />Al <br />FLOOR PLAN KEYNOTES <br />O EXISTING COPPER PIPE TO REMAIN <br />O WIRE WALL WITH LOCKABLE ENTRY DOOR <br />0 EXTEND EXISTING PARTITON TO STRUCTURE AND PROVIDE <br />ADDITIONAL (2) LAYERS OF GWB UP TO STRUCTURE <br />® EXISTING DOOR TO BE PERMANENTLY LOCKED & CLOSED <br />O5 NEW WALL INFILL TO MATCH ADJACENT EXISTING <br />THICKNESS AND WALL RATING: PROVIDE ACOUSTIC <br />INSULATION <br />© LOUVER ABOVE EXISTING DOOR, SEE MECHANICAL <br />DRAWINGS <br />O7 NEW RECESSED FIRE EXTINGUISHER CABINER <br />2013 4th Avenue, Suite 200 <br />Seattle, WA 98121 <br />Key Plan <br />Professional Seals <br />4825 <br />FLLW <br />ERED <br />ECT <br />ARNER <br />STATE OF WASHINGTON <br />No. Description Date <br />_ B BACK FILL ISSUED R PERMIT_ 2022/10/14 <br />KP Project No: CAP022566 <br />HOK Project No: 22.05003.00 <br />Sheet Title: <br />FLOOR PLAN - LEVEL <br />2-AREA E <br />Original is 30 x 42. Do not scale contents of this drawing- <br />Sheet Number <br />