My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST 2022 KAISER PERMANENTE Plans 2025-01-24
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
Plans
>
2930 MAPLE ST 2022 KAISER PERMANENTE Plans 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 10:15:12 AM
Creation date
6/26/2023 3:15:47 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Tenant Name
KAISER PERMANENTE
Permit
B2211-004
Year
2022
Notes
APPROX 10,039 SQ FT LEVEL P1, LEVEL 1 & 2 NEW CORRIDORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
w <br />REFLECTED CEILING PLAN LEVEL P1 - AREA E <br />1/4" = 1'-0" <br />N <br />CEILING PLAN GENERAL NOTES <br />1. SPRINKLER HEAD LOCATIONS ARE NOT SHOWN ON ARCHITECTURAL REFLECTED <br />CEILING PLAN. (EXISTING BUILDING IS "FULLYSPRINKLERED" PER NFPA 13 AND PER <br />OWNER'S INSURANCE COMPANY REQUIREMENTS.) <br />2. ALL EXISTING LIGHTING FIXTURES TO REMAIN, UON. <br />3. ALL EXISTING MECHANICAL DIFFUSERS TO REMAIN, LION. <br />4. ALL STROBES SHALL BE LOCATED @ 80" AFF. REFER TO ENGINEER'S DRAWINGS FOR <br />LOCATIONS AND SPECIFICATIONS, <br />5. ALL STROBES TO ALIGN VERTICALLY WITH RECEPTACLE BELOW WHERE OCCURS. <br />6. ARCHITECT TO REVIEW ALL LIGHT/CEILING FIXTURE LOCATIONS PRIOR TO <br />INSTALLATION. <br />7. INSTALL SUSPENDED CEILING GRID TO BE LEVEL WITHIN A TOLERANCE OF 1/81, IN <br />12'-0". ANCHOR AS REQUIRED. <br />8. ARCHITECT TO REVIEW LOCATIONS OF ALL SLOT DIFFUSERS, SPRINKLERS, SMOKE <br />DETECTORS, ETC. IN GYPSUM BOARD CEILINGS. <br />9. REFLECTED CEILING PLANS INDICATE: <br />A. GENERAL TYPE AND SPECIFIC LOCATION OF LIGHT FIXTURES OF SIGNAL AND <br />EQUIPMENT DEVICES. <br />10. ELECTRICAL ENGINEERING DRAWINGS INDICATE: <br />A. CIRCUITING AND WIRING OF LIGHT FIXTURES AND SWITCHES. <br />B. LIFE SAFETY EQUIPMENT, <br />C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. <br />D. LIGHT FIXTURE SPECIFICATIONS AND LOCATIONS. <br />11. MECHANICAL ENGINEERING DRAWINGS INDICATE: <br />A. DUCTS, AIR MOVEMENT REQUIREMENTS AND SIZES OF GRILLES AND REGISTERS. <br />12. WHERE ACOUSTICAL PANELS ARE REQUIRED TO BE CUT, CUT THE PANELS TO <br />MAINTAIN A SHARP AND NEAT EDGE. <br />13. INSTALL NEW SPRINKLER HEADS AND LIGHT FIXTURES AT THE CENTER OF THE <br />ACOUSTICAL CEILING PANEL LION. <br />14. ALL CEILING PAINT TO BE PT-2, WHERE NEW CEILING OCCURS UON. <br />15. PAINT ALL CEILING PANELS TO MATCH ADJACENT CEILING FINISH. <br />16. ACOUSTIC CEILING PANELS ARE CENTERED IN ROOM (BOTH DIRECTIONS) ABOUT <br />MAIN WALLS AS INDICATED GRAPHICALLY, UON. <br />17. ALL EXTERIOR WINDOWS TO RECEIVE WINDOW TREATMENT LION. <br />CEILING PLAN LEGEND <br />MATERIALS <br />EXISTING ROOM OR ZONE TO <br />REMAIN, NOT INCLUDED IN THIS <br />SCOPE OF WORK <br />2' x 2' GRID AND TILE SYSTEM <br />2' x 4' GRID AND TILE SYSTEM <br />GYPSUM BOARD CEILING <br />OPEN TO STRUCTURE ABOVE <br />WITH PAINTED FINISH <br />LIGHT FIXTURES <br />2'x2'RECESSED <br />2' x 4' RECESSED <br />O 4' RECESSED LINEAR <br />ANNOTATIONS <br />8' 6" <br />2' x 4' RECESSED <br />ACT <br />MATERIAL TYPE <br />— <br />FINISH DESIGNATION <br />LIFE SAFETY <br />EXIT SIGN <br />ARROW INDICATES PATH OF TRAVEL <br />SO <br />SMOKE DETECTOR <br />LIFE SAFETY SPEAKER STROBE <br />LIFE SAFETY SPEAKER <br />F <br />LIFE SAFETY STROBE <br />SCHEMATIC SPRINKLER HEAD <br />LOCATION <br />CEILING PLAN KEYNOTES <br />O EXISTING CEILING GRID & SYSTEM, <br />LIGHTING, HVAC AND FIRE <br />PROTECTION TO REMAIN <br />KAISER <br />PERMANENTE�. <br />Project <br />Kaiser Permanente Everett <br />MOB Backfill <br />2929 PINE STREET <br />EVERETT, WA 98201 <br />Prepared for <br />KAISER FOUNDATION <br />HEALTH PLAN, INC. <br />NATIONAL FACILITIES SERVICES <br />POST OFFICE BOX 12916 <br />OAKLAND, CA 94604 <br />Hellmuth, Obata & Kassabaum, Inc. <br />1218 Third Avenue, Suite 500 <br />Seattle, WA 98101 USA <br />t +1 206 493 1771 f +1 206 493 1778 <br />All reproduction & intellectual property rights reserved <br />2022 <br />In Association with <br />Mortenson <br />General Contractor <br />10230 NE Points Drive, Suite 300 <br />Kirkland, WA 98033 <br />Mazzetti <br />MEP + FP Engineering <br />2013 4th Avenue, Suite 200 <br />Seattle, WA 98121 <br />Key Plan <br />Professional Seals <br />4825 <br />REGISTERED <br />ARCHITECT <br />ARR LL W TURNER <br />STATE OF WASHINGTON <br />No. Description Date <br />KP Project No: CAP022566 <br />HOK Project No: 22.05003.00 <br />Sheet Title: <br />REFLECTED CEILING <br />PLAN - LEVEL P1 - <br />AREA E <br />Original is 30 x 42. Do not scale contents of this drawing. <br />Sheet Number <br />
The URL can be used to link to this page
Your browser does not support the video tag.