SHEET INDEX - MOB BACK FILL <br />THE SPECIFIED ITEM CODES WITH SUFFIXES ARE <br />LIST OF ABBREVIATIONS <br />DESIGNATIONS THAT RELATE TO ITEMS WHICH MAYBE TAGGED <br />IN THE CONSTRUCTION DOCUMENTS AND ARE FURTHER <br />DESCRIBED IN THE PROJECT SPECIFICATIONS. <br />A <br />L <br />A/C <br />AIR CONDITIONING <br />LAB <br />LABORATORY <br />AD <br />AREA DRAIN <br />LAT <br />LATERAL <br />ADA <br />AMERICANS WITH DISABILITIES ACT <br />LAV <br />LAVATORY <br />ADAAG <br />ADA ACCESSIBILITY GUIDELINES <br />LB <br />POUND <br />ADDL <br />ADDITIONAL <br />LF <br />LINEAR FOOT <br />ADJ <br />ADJUSTABLE <br />LL <br />LIVE LOAD <br />AFF <br />ABOVE FINISH FLOOR <br />LLH <br />LONG LEG HORIZONTAL <br />ALT <br />ALTERNATE <br />LLV <br />LONG LEG VERTICAL <br />ALUM <br />ALUMINUM <br />LP <br />LOW POINT <br />APC <br />ACOUSTICAL PANEL CEILING SYSTEM <br />LT <br />LIGHT <br />APPROX <br />APPROXIMATE <br />LV <br />LOW VOLTAGE <br />ARCH <br />ARCHITECTURAL <br />AV <br />AUDIO VISUAL <br />M <br />M <br />METER <br />B <br />MAINT <br />MAINTENANCE <br />B/ <br />BOTTOM OF (SEE OTHER WORD) <br />MAX <br />MAXIMUM <br />BLDG <br />BUILDING <br />MCC <br />MOTOR CONTROL CENTER <br />BSMT <br />BASEMENT <br />MDF <br />MEDIUM DENSITY FIBERBOARD <br />MDO <br />MEDIUM DENSITY OVERLAY <br />C <br />MECH <br />MECHANICAL <br />CAB <br />CABINET <br />MEP <br />MECHANICAL, ELECTRICAL, PLUMBING <br />CAT <br />CATEGORY <br />MER <br />MECHANICAL EQUIPMENT ROOM <br />CB <br />CATCH BASIN <br />MEZZ <br />MEZZANINE <br />Cl <br />CASTIRON <br />MFR <br />MANUFACTURER <br />CIP <br />CAST -IN -PLACE <br />MH <br />MANHOLE <br />CJ <br />CONTROL JOINT 1 CONSTRUCTION JOINT <br />MIN <br />MINIMUM <br />CL <br />CENTER LINE <br />MISC <br />MISCELLANEOUS <br />CLG <br />CEILING <br />MM <br />MILLIMETER <br />CLR <br />CLEAR <br />MTD <br />MOUNTED <br />CM <br />CENTIMETER <br />MTL <br />METAL <br />CMB <br />CEMENT BOARD <br />CMU <br />CONCRETE MASONRY UNIT <br />N <br />CO <br />CLEANOUT <br />N <br />NEWTON <br />COL <br />COLUMN <br />NIA <br />NOT APPLICABLE <br />CONC <br />CONCRETE <br />NC <br />NOISE CRITERIA <br />CONT <br />CONTINUOUS <br />NIC <br />NOT IN CONTRACT <br />COORD <br />COORDINATE <br />NO <br />NUMBER <br />CORR <br />CORRIDOR <br />NOM <br />NOMINAL <br />CS <br />CONCRETE SEALER <br />NPS <br />NOMINAL PIPE SIZE <br />CTR <br />CENTER <br />NRC <br />NOISE REDUCTION COEFFICIENT <br />NTS <br />NOT TO SCALE <br />D <br />DB <br />DECIBEL <br />0 <br />DEG <br />DEGREE <br />CA <br />OUTSIDE AIR <br />DEMO <br />DEMOLITION <br />OC <br />ON CENTER <br />DEPT <br />DEPARTMENT <br />OCEW <br />ON CENTER EACH WAY <br />DET <br />DETAIL <br />OD <br />OUTSIDE DIAMETER/DIMENSION <br />DF <br />DRINKING FOUNTAIN <br />OFCI <br />OWNER FURNISHED, CONTRACTOR INSTALLED <br />DIA <br />DIAMETER <br />OFOI <br />OWNER FURNISHED, OWNER INSTALLED <br />DIFF <br />DIFFUSER <br />OH <br />OVER HEAD <br />DIM <br />DIMENSION <br />OPNG <br />OPENING <br />DL <br />DEAD LOAD <br />OPP <br />OPPOSITE <br />DN <br />DOWN <br />OPP HD <br />OPPOSITE HAND <br />DP <br />DESIGN/DIMENSION POINT <br />OXY <br />OXYGEN <br />DR <br />DOOR <br />DRN <br />DRAIN <br />P <br />DW <br />DISHWASHER <br />PAF <br />POWER -ACTUATED FASTENER <br />DWG <br />DRAWING <br />PBD <br />PARTICLEBOARD <br />PD <br />PERIMETER DRAIN <br />E <br />PERF <br />PERFORATED <br />EA <br />EACH <br />PL <br />PLATE <br />EFS <br />EXTERIOR FINISH SYSTEM <br />PLBG <br />PLUMBING <br />EIFS <br />EXTERIOR INSULATION AND FINISH SYSTEM <br />PLF <br />POUNDS PER LINEAR FOOT <br />EL <br />ELEVATION <br />PR <br />PAIR <br />ELEC <br />ELECTRICAL <br />PREFAB <br />PREFABRICATED <br />EMERG <br />EMERGENCY <br />PSF <br />POUNDS PER SQUARE FOOT <br />ENCL <br />ENCLOSURE <br />PSI <br />POUNDS PER SQUARE INCH <br />EP <br />ELECTRICAL PANELBOARD <br />PTD <br />PAINTED <br />EQ <br />EQUAL <br />PTN <br />PARTITION <br />EQUIP <br />EQUIPMENT <br />EWC <br />ELECTRICAL WATER COOLER <br />Q <br />EXH <br />EXHAUST <br />QTY <br />QUANTITY <br />EXIST <br />EXISTING <br />EXP <br />EXPANSION <br />R <br />EXT <br />EXTERIOR <br />R <br />RADIUS <br />RA <br />RETURN AIR <br />F <br />RCP <br />REFLECTED CEILING PLAN <br />F/ <br />FACE OF (SEE OTHER WORD) <br />RD <br />ROOF DRAIN <br />FA <br />FIRE ALARM <br />RECPT <br />RECEPTACLE <br />FD <br />FLOOR DRAIN <br />REF <br />REFERENCE <br />FDC <br />FIRE DEPARTMENT CONNECTION <br />REFR <br />REFRIGERATOR <br />FDN <br />FOUNDATION <br />REINF <br />REINFORCED / REINFORCING <br />FE <br />FIRE EXTINGUISHER <br />REQ <br />REQUIRE 1 REQUIRED <br />FEC <br />FIRE EXTINGUISHER CABINET <br />REV <br />REVISION I REVISED <br />FEQ <br />FOOF EQUIPMENT <br />RM <br />ROOM <br />FF <br />FINISH FLOOR <br />RO <br />ROUGH OPENING <br />FF&E <br />FURNITURE, FIXTURES & EQUIPMENT <br />FHC <br />FIRE HOSE CABINET <br />S <br />FIN <br />FINISH <br />SA <br />SUPPLY AIR <br />FL <br />FLOOR <br />SAFB <br />SOUND ATTENUATING FIRE BLANKETIBATT <br />FLUOR <br />FLUORESCENT <br />SAN <br />SANITARY <br />FO <br />FINISHED OPENING <br />SCHED <br />SCHEDULE <br />FRTW <br />FIRE RETARDANT TREATED WOOD <br />SD <br />STORM DRAIN <br />FS <br />FIRE STOPPING <br />SECT <br />SECTION <br />FT <br />FEET/FOOT <br />SF <br />SQUARE FEETTOOT <br />FTG <br />FOOTING <br />SFRM <br />SPRAY APPLIED FIRE -RESISTIVE MATERIAL <br />FURN <br />FURNITURE <br />SHR <br />SHOWER <br />SHT <br />SHEET <br />G <br />SIM <br />SIMILAR <br />GA <br />GAUGE/GAGE <br />SM <br />SQUARE METER <br />GALV <br />GALVANIZED <br />SMS <br />SHEET METAL SCREW <br />GC <br />GENERAL CONTRACTOR, GENERAL CONTRACT <br />SP <br />STANDPIPE <br />GFRC <br />GLASS FIBER REINFORCED CONCRETE <br />SPEC <br />SPECIFICATION <br />GFRG <br />GLASS FIBER REINFORCED GYPSUM <br />SPKR <br />SPEAKER <br />GFRP <br />GLASS FIBER REINFORCED PLASTIC <br />SPR <br />SPRINKLER <br />GR <br />GRADE <br />SQ <br />SQUARE <br />GWB <br />GYPSUM WALLBOARD <br />SST <br />STAINLESS STEEL <br />STD <br />STANDARD <br />H <br />STL <br />STEEL <br />HB <br />HOSE BIBB <br />STMS <br />SELF -TAP SHEET METAL SCREW <br />HC <br />HANDICAPPED <br />STRL <br />STRUCTURAL <br />HM <br />HOLLOW METAL <br />SUSP <br />SUSPENDED <br />HO <br />HOLD -OPEN <br />SYMM <br />SYMMETRICAL <br />HORIZ <br />HORIZONTAL <br />HP <br />HIGH POINT <br />T <br />HR <br />HOUR <br />T&G <br />TONGUE AND GROOVE <br />HRC <br />HOSE REEL CABINET <br />T/ <br />TOP OF (SEE OTHER WORD) <br />HSS <br />HOLLOW STRUCTURAL SECTION <br />TEL <br />TELEPHONE OR TELECOM <br />HT <br />HEIGHT <br />TEMP <br />TEMPERATURE <br />HVAC <br />HEATING, VENTILATING, AIR CONDITIONING <br />TGB <br />TOGGLE BOLT <br />HW <br />HOT WATER <br />THK <br />THICKNESS <br />TP <br />TOILET PARTITION <br />I <br />TV <br />TELEVISION <br />ICB <br />INTEGRAL COVE BASE <br />TYP <br />TYPICAL <br />ICC <br />INTERNATIONAL CODE COUNCIL <br />ID <br />INSIDE DIAMETER I DIMENSION <br />U <br />IN <br />INCH <br />UL <br />UNDERWRITERS LABORATORY <br />INFO <br />INFORMATION <br />UON <br />UNLESS OTHERWISE NOTED <br />INT <br />INTERIOR <br />INV <br />INVERT <br />V <br />VERT <br />VERTICAL <br />J <br />VEST <br />VESTIBULE <br />JC <br />JANITOR'S CLOSET <br />VIF <br />VERIFY IN FIELD <br />JST <br />JOIST <br />JT <br />JOINT <br />W <br />WI <br />WITH <br />K <br />W/0 <br />WITHOUT <br />Q K <br />KIP (1000 LB) <br />WC <br />WATER CLOSET <br />N KG <br />KILOGRAM <br />WDS <br />WOOD SCREW <br />M KIT <br />KITCHEN <br />WP <br />WORK POINT <br />WT <br />WEIGHT <br />a <br />WWR <br />WELDED WIRE REINFORCING <br />o_ <br />N <br />N <br />O <br />N <br />GENERAL NOTES <br />A. GENERAL NOTES: <br />1. THE CONTRACTOR SHALL PROVIDE COMPLETE PROJECT SYSTEMS AND COMPONENTS AND COMPLY <br />WITH ALL REQUIREMENTS INDICATED ON THE PROJECT DOCUMENTS. <br />2. WORK WITHIN THE AREA BOUNDARIES INDICATED IN THE PROJECT DOCUMENTS, AND COMPLY WITH <br />ALL APPLICABLE BUILDING CODE, REGULATION, & ORDINANCE REQUIREMENTS. OCCUPANTS ADJACENT <br />TO THE PROJECT AREA BOUNDARIES SHALL CONTINUE UNINTERRUPTED OCCUPANCY DURING <br />CONSTRUCTION OF THE PROJECT <br />3. VERIFY FIELD CONDITIONS AND COORDINATION WITH THE PROJECT DOCUMENTS PRIOR TO <br />PROCEEDING WITH THE WORK. <br />4. COORDINATE THE WORK WITH ALL REQUIREMENTS INDICATED IN THE PROJECT DOCUMENTS. <br />5. PERFORM THE WORK AT THE PROJECT SITE DURING NORMAL BUSINESS HOURS, UNLESS OTHERWISE <br />NOTED. <br />6. COORDINATE THE WORK WITH EQUIPMENT, FURNISHINGS, AND SYSTEMS PROVIDED BY THE OWNER. <br />B. DEFINITIONS: <br />1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM SHALL BE PROVIDED FOR EACH <br />OCCURRENCE OF THE CONDITION NOTED. <br />2. "SIMILAR" INDICATES COMPLETE SYSTEM AND COMPONENTS SHALL BE PROVIDED COMPARABLE TO <br />THE CHARACTERISTICS FOR THE CONDITION NOTED. <br />3. "AS REQUIRED" INDICATES COMPONENTS REQUIRED TO COMPLETE THE NOTED, SYSTEM AS <br />INDICATED IN THE PROJECT DOCUMENTS, SHALL BE PROVIDED. <br />4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND <br />PLUMB RELATION TO ADJACENT MATERIALS. <br />C. DIMENSIONS: <br />1. DIMENSIONS ARE INDICATED TO THE CENTERLINE OF THE STRUCTURAL GRID, FACE OF CONCRETE <br />WALL, NOMINAL FACE OF CMU WALL, FACE OF PARTITION TYPE AS SCHEDULED, LION <br />2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. THE <br />PRIORITY FOR PROJECT DIMENSIONS SHALL BE IN THE FOLLOWING ORDER: <br />A. MIN DIMENSION FOR ACCESSIBILITY CLEARANCE & BUILDING CODE REQUIREMENT <br />B. LARGE SCALE DETAILS <br />C. SMALL SCALE DETAILS <br />D. ENLARGED VIEWS <br />E. FLOOR PLANS AND ELEVATIONS <br />3. FLOOR ELEVATIONS ARE INDICATED TO THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE <br />NOTED. <br />4. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL <br />AT THE DIMENSION POINT, UNLESS NOTED ABOVE FINISH FLOOR -"AFF". <br />5. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED <br />CEILING SYSTEM OR FACE OF FINISH MATERIAL AS SCHEDULED. <br />6. DIMENSIONS SHOWN ON THE DRAWINGS SHALL INDICATE THE REQUIRED SIZE, CLEARANCE, AND <br />DIMENSIONAL RELATIONSHIP BETWEEN PROJECT SYSTEMS AND COMPONENTS. DIMENSIONS SHALL <br />NOT BE DETERMINED BY SCALING THE DRAWINGS. <br />D. DRAWING SET ORGANIZATION: <br />1. EACH DRAWING SET SHEET IS IDENTIFIED BY THE SHEET NUMBER IN THE LOWER RIGHT HAND <br />CORNER OF THE DRAWING TITLE BLOCK. THE SHEET TITLE PROVIDES A GENERAL DESCRIPTION OF <br />THE CONTENTS OF THE SHEET. <br />SHEET NUMBER EXAMPLE: A201 <br />W INDICATES THE DISCIPLINE THAT CREATED THE DRAWING <br />7 INDICATES THE DRAWING CATEGORY CONTAINED ON THE SHEET <br />"01" INDICATES THE SHEET NUMBER <br />2. SHEET NUMBERS MAY INCLUDE SUPPLEMENTAL CHARACTERS TO PROVIDE ADDITIONAL INFORMATION, <br />SUCH AS DRAWING CONTENT, PROJECT SECTOR OR PHASE. REFER TO THE DRAWING INDEX FOR A <br />COMPLETE LIST OF SHEETS INCLUDED IN THE DOCUMENT SET. <br />EXAMPLE: B1 201A <br />"B1" INDICATES THE BACKFILL PROJECT PHASE NUMBER <br />"EL" INDICATES THE DISCIPLINE THAT CREATED THE DRAWING AND THE DRAWING CONTENT = <br />ELECTRICAL LIGHTING <br />"A" INDICATES SECTOR "A" OF PLAN SHEET "201". REFER TO THE PROJECT KEY PLAN OR <br />COMPOSITE PLAN INDICATING THE RELATIONSHIP OF THE SECTORS. <br />3. DRAWING SET INDEX INDICATES THE COMPLETE LIST OF SHEETS CONTAINED IN THE DRAWING SET, <br />INDEXED BY DISCIPLINE, SHEET NUMBER AND SHEET TITLE, IN SEQUENTIAL ORDER. NOTE THAT ALL <br />SEQUENTIAL SHEET NUMBERS MAY BE NOT USED IN THE DRAWING SET. <br />4. DISCIPLINE IDENTIFICATION, IN ORDER BOUND IN THE DRAWING SET. REFER TO THE DRAWING SET <br />INDEX FOR DISCIPLINE CONTAINED IN THIS DRAWING SET: <br />G GENERAL INFORMATION M MECHANICAL <br />A ARCHITECTURAL E ELECTRICAL <br />M MECHANICAL P PLUMBING <br />5. DRAWING CATEGORY IDENTIFICATION. REFER TO THE DRAWING SET INDEX FOR DISCIPLINES, <br />CATEGORIES, AND SHEET NUMBERS CONTAINED IN THIS DRAWING SET: <br />ANNOTATION SYMBOLS <br />VIEW TITLE <br />VIEW NUMBER <br />TITLE- VIEWTITLE <br />1 118" = V-0" <br />VIEW SCALE <br />GRAPHIC SYMBOLS <br />CALLED NORTH <br />N ,- <br />TRUE NORTH <br />PROPERTY LINE <br />SHEET REFERENCE SYMBOL <br />1 VIEW NUMBER <br />A201 SHEET NUMBER <br />I� <br />CATEGORY <br />DISCIPLINE <br />BUILDING / WALL SECTION REFERENCES <br />REFER TO THIS <br />SHEET IDENTIFICATION <br />3 <br />A701 <br />BUILDING 4 <br />SECTION A751 <br />WALL SECTION <br />ELEVATION REFERENCES <br />SCOPE OF REFER TO THIS <br />NEW WORK <br />SHEET IDENTIFICATION <br />- - EXISTING WORK 1 <br />1 4 A601 2 <br />ALIGN A501 <br />-�- INDICATES FINISHED <br />SURFACES SHALL ALIGN 3 <br />EXTERIOR ELEVATION INTERIOR ELEVATION <br />DETAIL <br />REFERENCES REFER TO THIS <br />1 COLUMN CENTER SHEET IDENTIFICATION <br />LINE <br />11 <br />A COLUMN GRID A301 / <br />LABEL <br />DETAIL CALLOUT 2 <br />DIMENSION LINES <br />5-V �- CENTERLINE <br />o <br />u <br />a l <br />J <br />H MATCHLINE SEE: A/A201 <br />MATCHLINE SEE: A/A202 <br />ELEVATION SYMBOLS <br />FL EL <br />ELEVATION DATUM <br />0'-T <br />DP <br />DIMENSION POINT <br />EL +12" <br />OIL <br />INDICATES +/- FROM <br />REF ELEVATION <br />DETAIL SECTION <br />ROOM NAME / NUMBER SYMBOL <br />ROOM NAME ROOM IDENTIFICATION <br />101 - ROOM NUMBER <br />PARTITION TYPE, DOOR, AND MISC SYMBOLS <br />DOOR NUMBER <br />PARTITION TYPE TAG <br />FINISH TAG <br />0 <br />P11 I <br />KEY NOTE <br />REVISED AREA <br />REVISION CLOUD <br />REVISION NUMBER <br />GENERAL PROJECT INFORMATION <br />PROJECT OWNER: KAISER PERMANENTE <br />PROJECT SITE ADDRESS: 2930 MAPLE ST, EVERETT, WA 98201 <br />PARCEL NUMBER: 004390-695-058-00 <br />LEGAL DESCRIPTION: SECTION 29 TOWNSHIP 29 RANGE 05 QUARTER NE EVERETT LAND CO S 1ST ADD BLK 695 <br />D-00 - LOTS 58 THRU 70 BLK 695 SD PLAT TGW LOTS 27-28 & S 5FT OF LOT 29 BLK 695 PLAT OF SWALWELLS 2ND ADD <br />ZONING: MU <br />EXISTING BUILDING CONSTRUCTION - TYPE IIA <br />DATE OF CONSTRUCTION: 1994 <br />EXISTING BUILDING SPACE CONDITIONING: FULLY -CONDITIONED <br />EXISTING BUILDING INFORMATION: TWO STORY MEDICAL OFFICE BUILDING WITH TWO (2) STORIES OF ABOVE - <br />GRADE STRUCTURED PARKING <br />NUMBER OF EXISTING BUILDING STORIES: 2 STORY <br />EXISTING BUILDING TOTAL FLOOR AREA: 141,067 SF <br />EXISTING USE AND OCCUPANCY CLASSIFICATION - B - MEDICAL CLINIC <br />PROJECT SCOPE DOES NOT CHANGE BASED ON BUILDING CONSTRUCTION CLASSFICATION <br />PROJECT SCOPE DOES NOT CHANGE BUILDING AREA <br />PROJECT SCOPE DOES NOT CHANGE BUILDING HEIGHT <br />PROJECT SCOPE DOES NOT INCLUDE ANY MODIFICATION TO EXTERIOR BUILDING <br />FIRE RESISTANCE RATING REQUIREMENTS: AS PER TABLE 601 <br />PRIMARY STRUCTURAL FRAME: 1 HOUR <br />EXTERIOR BEARING WALL: 1 HOUR <br />INTERIOR BEARING WALL: 1 HOUR <br />INTERIOR NON -BEARING WALL: 0 HOUR <br />FLOOR CONSTRUCTION; 1 HOUR <br />ROOF CONSTRUCTION: 1 HOUR <br />SPRINKLER DECLARATION: EXISTING FULLY SPRINKLERED IN ACCORDANCE WITH 2O18 IBC CHAPTER 9 <br />NEW FIT OUT AREA OF SCOPE OF WORK: <br />LEVEL P1 - "T OCCUPANCY - 2,648 SF (NO CHANGE IN OCCUPANCY) <br />LEVEL 1 -"B" OCCUPANCY - 2,652 SF (NO CHANGE IN OCCUPANCY) <br />LEVEL 2 -"B" OCCUPANCY - 2,353 SF (NO CHANGE IN OCCUPANCY) <br />LEVEL 2 - "B" OCCUPANCY - 2,286 SF (NO CHANGE IN OCCUPANCY) <br />TOTAL PROJECT AREA-10,039 SF <br />NEW FIT OUT OCCUPANCY CLASSIFICATION AND USE GROUP: GROUP B/BUSINESS-OFFICE <br />MEANS OF EGRESS COMPONENTS: <br />THE EGRESS PLAN SHEETS ILLUSTRATE THAT THE NEW PLAN CONFIGURATION COMPLY WITH THE FOLLOWING: <br />OVERALL LENGTH OF TRAVEL I TABLE 1017.2 = 300 FEET, MAX <br />COMMON PATH OF TRAVEL / TABLE 1006.2.1 =100 FEET, MAX <br />DEAD END CORRIDOR LENGTH / TABLE 1020.4 = 50 FEET, MAX <br />CORRIDOR AND PATHWAY WIDTH / TABLE 1020.2 = 36 INCHES WIDE MIN. WHEN LESS THAN 50 PEOPLE <br />CORRIDOR AND PATHWAY WIDTH / TABLE 1020.2 = 44 INCHES WIDE, MIN WHEN LESS THAN 50 PEOPLE <br />STAIR CAPACITY FACTOR / SECTION 1005.3.1 = 0.20 INCHES PER PERSON, SPRINKLERED BUILDING <br />DOOR CAPACITY FACTOR / SECTION 1005.3.2 = 0.15 INCHES PER PERSON, SPRINKLERED BUILDING <br />APPLICABLE CODES & ORDINANCES: <br />2018 IBC WITH WA AMENDMENTS <br />2018 INTERNATIONAL MECHANICAL CODE <br />2017 NFPA 70, NATIONAL ELECTRICAL CODE NEC <br />2018 UNIFORM PLUMBING CODE <br />2018 INTERNATIONAL FIRE CODE <br />2018 WASHINGTON STATE ENERGY CODE <br />ANSI I ASME A17-1 <br />NFPA 13 <br />NFPA 72 <br />ICC / ANSI Al 17.1-2009 <br />2018 NFPA 101, LIFE SAFETY CODE <br />2019 NFPA 110 STANDARD FOR EMERGENCY & STANDBY POWER SYSTEMS <br />LOCATION MAP <br />PROJECT LOCATION N <br />PROJECT DESCRIPTION <br />THE TENANT IMPROVEMENT SCOPE OF WORK INCLUDES THE DESIGN AND BUIL-OUT OF APPROXIMATELY 10,039 <br />TOTAL SF. EXISTING OFFICES AND WORK AREAS IN LEVEL P1 WILL BE DEMOLISHED AND RECONFIGURED TO <br />ACCOMODATE THE RELOCATED SECURITY, MAIL ROOM, FACILITIES, IT AND MATERIAL MANAGEMENT OFFICES AND <br />WORK AREAS. EXISTING OFFICES, MAIL ROOM AND STAFF LOUNGE AT LEVEL 1 AREA E WILL BE DEMOLISHED AND <br />RECONFIGURED TO ACCOMODATE THE NEW CORRIDOR THAT WILL CONECT TO THE FUTURE AMBULATORY <br />SURGERY CENTER LEVEL 3. EXISTING OFFICES AT LEVEL 2 AREA E WILL BE DEMOLISHED TO PROVIDE CORRIDOR <br />THAT WILL CONNECT TO FUTURE AMBULATORY SURGERY CENTER LEVEL 4 AND THE LEVEL 2 AREA E OFFICES <br />WILL BE MOVED TO EXISTING VACANT OFFICE AT LEVEL 2 AREA F. <br />DEFERRED SUBMITTAL ITEMS <br />DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. DOCUMENTS <br />FOR DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN <br />RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A <br />NOTATION INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND FOUND TO BE IN <br />GENERAL CONFORMANCE TO THE DESIGN OF THE BUILDING, THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE <br />INSTALLED UNTIL THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. <br />INTERIOR ALUMINUM -FRAMED ENTRANCES AND <br />STOREFRONTS <br />INTERIOR GLAZING <br />SEISMIC DESIGN OF NON-STRUCTURAL COMPONENTS <br />- ACOUSTICAL PANEL CEILINGS <br />- METAL STORAGE SHELVING <br />FIRE PROTECTION <br />PROJECT CONTACT LIST <br />OWNER: <br />KAISER PERMANENTE EVERETT MEDICAL CENTER <br />ATTN: TYLER CLARK <br />TEL: 425-478-2129 <br />EMAIL: tyler.n.clark@kp.org <br />ARCHITECT: <br />HOK <br />ATTN: GEMMA MECHURE <br />TEL: 206-353-6228 <br />EMAIL: gemma.mechure@hok.com <br />GENERAL CONTRACTOR: <br />MORTENSON <br />ATTN: BRIAN CHAPMAN <br />TEL: 517-282-7902 <br />EMAIL: brian.chapman@mortenson.com <br />SHEET <br />NUMBERI SHEET NAME <br />01 GENERAL <br />B1 G000 COVER SHEET <br />B1 G001 ABBREVIATIONS, ANNOTATIONS, NOTES, SYMBOLS AND INDEX <br />B1 G002 ADAAG BUILDING ACCESSIBILITY DIAGRAMS <br />06 ARCHITECTURE <br />B1 G10P1 <br />LIFE SAFETY PLAN - LEVEL P1 <br />B1 G101 <br />LIFE SAFETY PLAN - LEVEL 1 <br />B1 G102 <br />LIFE SAFETY PLAN - LEVEL 2 <br />B1 AD10P1 <br />DEMO PLAN - LEVEL P1 - AREA E <br />B1 AD101 E <br />DEMO PLAN - LEVEL 1 - AREA E <br />B1 AD102E <br />DEMO PLAN - LEVEL 2 - AREA E <br />61 AD102F <br />DEMO PLAN - LEVEL 2 - AREA F <br />B1 A001 <br />SITE PLAN <br />B1 A10P1 <br />OVERALL PLAN - LEVEL P1 <br />B1 A101 <br />OVERALL FLOOR PLAN - LEVEL 1 <br />B1 A102 <br />OVERALL FLOOR PLAN - LEVEL 2 <br />B1 A20P1 <br />FLOOR PLAN - LEVEL P1 - AREA E <br />B1 A201E <br />FLOOR PLAN - LEVEL 1 AREA E <br />B1 A202E <br />FLOOR PLAN - LEVEL 2 - AREA E <br />B1 A202F <br />FLOOR PLAN - LEVEL 2 AREA F <br />B1 A30P1 <br />REFLECTED CEILING PLAN - LEVEL P1 - AREA E <br />B1 A301 E <br />REFLECTED CEILING PLAN - LEVEL 1 - AREA E <br />B1 A302E <br />REFLECTED CEILING PLAN - LEVEL 2 - AREA E <br />B1 A302F <br />REFLECTED CEILING PLAN - LEVEL 2 - AREA F <br />B1 A40P1 <br />FURNITURE & EQUIPMENT PLAN - LEVEL P1 - AREA E <br />B1 A402F <br />FURNITURE & EQUIPMENT PLAN - LEVEL 2 - AREA F <br />B1 A50P1 <br />FINISH PLAN - LEVEL P1 -AREA E <br />61 A501E <br />FINISH PLAN - LEVEL 1 - AREA E <br />B1 A502E <br />FINISH PLAN - LEVEL 2 - AREA E <br />B1 A502F <br />FINISH PLAN - LEVEL 2 - AREA F <br />B1 A701 <br />TOILET ENLARGED PLAN AND INTERIOR ELEVATIONS <br />B1 A900 <br />DOOR AND WINDOW SCHEDULE AND DOOR DETAILS <br />B1 A901 <br />INTERIOR FINISH DETAILS <br />B1 A910 <br />INTERIOR GWB PARTITION TYPES <br />B1 A911 <br />INTERIOR GWB PARTITION DETAILS <br />B1 A912 <br />CEILING FRAMING DETAILS <br />B1 A913 <br />CEILING SYSTEM DETAILS <br />110 PLUMBING <br />B1 P001 <br />PLUMBING COVER SHEET <br />61 P002 <br />PLUMBING 2018 WSEC COMPLIANCE AND EQUIPMENT SCHEDULES <br />B1 PD10P1 <br />DEMO PLUMBING FLOOR PLAN - LEVEL P1 - AREA E <br />B1 PD102F <br />DEMO PLUMBING FLOOR PLAN - LEVEL 2 - AREA F <br />B1 P20P1 <br />PLUMBING FLOOR PLAN- LEVEL P1 - AREA F <br />B1 P202F <br />PLUMBING FLOOR PLAN - LEVEL 2 - AREA F <br />B1 F30P1 <br />FIRE PROTECTION FLOOR PLAN - LEVEL P1 - AREA E <br />61 F301 E <br />FIRE PROTECTION FLOOR PLAN - LEVEL 1 - AREA E <br />B1 F302E <br />FIRE PROTECTION FLOOR PLAN - LEVEL 2 - AREA E <br />B1 F302F <br />FIRE PROTECTION FLOOR PLAN - LEVEL 2 - AREA F <br />B1 P801 <br />PLUMBING SPECIFICATIONS <br />111 MECHANICAL <br />B1 M001 <br />MECHANICAL COVER SHEET <br />B1 M011 <br />MECHANICAL 2018 WSEC COMPLIANCE AND EQUIPMENT SCHEDULES <br />B1 MD10P1 <br />DEMO HVAC FLOOR PLAN - LEVEL P1 - AREA E <br />B1 MD101 E <br />DEMO HVAC FLOOR PLAN - LEVEL 1 - AREA E <br />B1 MD102E <br />DEMO HVAC FLOOR PLAN - LEVEL 2 - AREA E <br />B1 MD102F <br />DEMO HVAC FLOOR PLAN - LEVEL 2 - AREA F <br />B1 M20P1 <br />HVAC FLOOR PLAN - LEVEL P1 - AREA E <br />B1 M201 E <br />HVAC FLOOR PLAN - LEVEL 1 - AREA E <br />B1 M202E <br />HVAC FLOOR PLAN - LEVEL 2 - AREA E <br />61 M202F <br />HVAC FLOOR PLAN - LEVEL 2 - AREA F <br />B1 M601 <br />MECHANICAL DETAILS AND DIAGRAMS <br />B1 M701 <br />MECHANICAL CONTROLS <br />B1 M801 <br />MECHANICAL SPECIFICATIONS <br />112 ELECTRICAL <br />B1 E001 <br />ELECTRICAL SYMBOLS AND NOTES <br />61 E002 <br />NREC FORMS <br />B1 E003 <br />NREC FORMS <br />B1 E004 <br />NREC FORMS <br />B1 E005 <br />NREC FORMS <br />B1 E006 <br />NREC FORMS <br />B1 ED100E <br />DEMO ELECTRICAL FLOOR PLAN - LEVEL P1 - AREA E <br />B1 ED101 E <br />DEMO ELECTRICAL FLOOR PLAN - LEVEL 1 - AREA E <br />B1 ED102E <br />DEMO ELECTRICAL FLOOR PLAN - LEVEL 2 - AREA E <br />B1 ED102F <br />DEMO ELECTRICAL FLOOR PLAN - LEVEL 2 - AREA F <br />B1 E10P1 <br />OVERALL LEVEL P1 PLAN <br />B1 E101 <br />OVERALL LEVEL 1 PLAN <br />B1 E102 <br />OVERALL LEVEL 2 PLAN <br />B1 E20Pl E <br />LIGHTING PLAN - LEVEL P1 - AREA E <br />61 E201E <br />LIGHTING PLAN - LEVEL 1 -AREA E <br />B1 E202E <br />LIGHTING PLAN - LEVEL 2 - AREA E <br />B1 E202F <br />LIGHTING PLAN - LEVEL 2 - AREA F <br />B1 E30Pl E <br />POWER FLOOR PLAN - LEVEL P1 - AREA E <br />B1 E301 E <br />POWER FLOOR PLAN - LEVEL 1 - AREA E <br />B1 E302E <br />POWER FLOOR PLAN - LEVEL 2 - AREA E <br />B1 E302F <br />POWER FLOOR PLAN - LEVEL 2 - AREA F <br />B1 E40P1 E <br />FIRE ALARM FLOOR PLAN - LEVEL P1 - AREA E <br />B1 E401 E <br />FIRE ALARM FLOOR PLAN - LEVEL P1 - AREA E <br />B1 E402E <br />FIRE ALARM FLOOR PLAN - LEVEL 1 - AREA E <br />B1 E402F <br />FIRE ALARM FLOOR PLAN - LEVEL 2 - AREA F <br />B1 E601 <br />PARTIAL ONE -LINE DIAGRAM <br />B1 E701 <br />ELECTRICAL DETAILS <br />61 E801 <br />PANEL SCHEDULES <br />B1 E802 <br />PANEL SCHEDULES <br />113 TECHNOLOGY <br />B1 T000 <br />TECHNOLOGY LEGEND/INDEX SHEET <br />B1 T10P1 <br />TECHNOLOGY OVERALL LEVEL P1 <br />B1 T20P1 <br />TECHNOLOGY FLOOR PLAN - LEVEL P1 - AREA E <br />B1 T101 <br />TECHNOLOGY OVERALL LEVEL 1 <br />B1 T201E <br />TECHNOLOGY FLOOR PLAN - LEVEL 1 -AREA E <br />B1 T102 <br />TECHNOLOGY OVERALL LEVEL 2 <br />B1 T202E <br />TECHNOLOGY FLOOR PLAN - LEVEL 2 - AREA E <br />B1 T202F <br />TECHNOLOGY FLOOR PLAN - LEVEL 2 - AREA F <br />i KAISER <br />a PERMANEiVTE , <br />Project <br />Kaiser Permanente Everett <br />MOB Backfill <br />2929 PINE STREET <br />EVERETT, WA 98201 <br />Prepared for <br />KAISER FOUNDATION <br />HEALTH PLAN, INC. <br />NATIONAL FACILITIES SERVICES <br />POST OFFICE BOX 12916 <br />OAKLAN D, CA 94604 <br />Hellmuth, Obata & Kassabaum, Inc. <br />1218 Third Avenue, Suite 500 <br />Seattle, WA 98101 USA <br />t +1 206 493 1771 f +1 206 493 1778 <br />All reproduction & intellectual property rights reserved <br />2022 <br />In Association with <br />Mortenson <br />General Contractor <br />10230 NE Points Drive, Suite 300 <br />Kirkland, WA 98033 <br />Mazzetti <br />MEP + FP Engineering <br />2013 4th Avenue, Suite 200 <br />Seattle, WA 98121 <br />Key Plan <br />Professional Seals <br />4825 <br />REGISTERED <br />ARCHITECT <br />e <br />W TURNER <br />ASHINGTON <br />Sheet Title: <br />ABBREVIATIONS, <br />ANNOTATIONS, <br />NOTES, SYMBOLS <br />AND INDEX <br />Original is 30 x 42. Do not scale contents of this drawing. <br />Sheet Number <br />B1 G001 <br />