My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2930 MAPLE ST 2022 KAISER PERMANENTE Plans 2025-01-24
>
Address Records
>
MAPLE ST
>
2930
>
KAISER PERMANENTE
>
Plans
>
2930 MAPLE ST 2022 KAISER PERMANENTE Plans 2025-01-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/24/2025 10:15:12 AM
Creation date
6/26/2023 3:15:47 PM
Metadata
Fields
Template:
Address Document
Street Name
MAPLE ST
Street Number
2930
Tenant Name
KAISER PERMANENTE
Permit
B2211-004
Year
2022
Notes
APPROX 10,039 SQ FT LEVEL P1, LEVEL 1 & 2 NEW CORRIDORS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
35
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 E 2E 3E 4E 5E 6E 7E 8E 9E 110E) 111 E) 112E1 113EI 114E) 115EI 116EI 117EI 118E► 119EI 120EI 24.2 121 El i22E1 123E) 241 E 125EI 126E) 127E) <br />LIFE SAFETY PLAN - LEVEL P1 <br />3/32" = V-0" <br />N <br />O <br />O <br />N <br />0 <br />N <br />N <br />O <br />N <br />FIRE RATING LEGEND <br />1-HR RATED FIRE BARRIER <br />1111111 2-HR RATED FIRE BARRIER <br />444 3-HR RATED FIRE WALL <br />S1 SO— 1-HR RATED SMOKE BARRIER <br />LIFE SAFETY LEGEND <br />DEAD END DISTANCE* (2015 IBC 1020.4) <br />��oE�EHo <br />MAX = 50 FT <br />EXIT TRAVEL DISTANCE* (2015 IBC 1017.2) <br />�iAV L DISTN4 X P GROUP A, M = 250 FT <br />GROUP B = 300 FT <br />COMMON PATH OF TRAVEL* (2015 IBC 1006.2) <br />COMMON PATH OF TRAVEL 1' ► GROUP A, M = 75 FT <br />GROUP B=100FT <br />I FE <br />FIRE EXTINGUISHER <br />I FEC <br />FIRE EXTINGUISHER CABINET <br />RFEC <br />RECESSED FIRE EXTINGUISHER CABINET <br />EXIT <br />NOT IN CONTRACT <br />OCCUPANCY LEGEND <br />GROUP B - AMBULATORY CARE, CLINIC, OFFICE <br />100 SF OLD_ <br />GROUP B - BUSINESS, ACCESSORY, LOCKER <br />(50 SF OLF) <br />GROUP S - STORAGE, ACCESORY, MECHANICAL <br />(300 SF OLF) <br />M - MERCANTILE, RETAIL <br />(60 SF OLF) <br />A-3 - ASSEMBLY, CONFERENCE ROOMS <br />(15 SF OLF) <br />A-3 - ASSEMBLY, QUEUEING <br />5 SF OLF) <br />OLF = OCCUPANT LOAD FACTOR <br />EGRESS SCHEDULE <br />P1 - CLINIC <br />STAIR NAME <br />WIDTH <br />OCC. <br />LOAD <br />FACTOR <br />PROVIDED <br />EGRESS LOAD <br />CAPACITY <br />REQUIRED <br />EGRESS LOAD <br />CAPACITY <br />STAIR 1 <br />56" <br />0.2 <br />280 <br />73 <br />STAIR 2 <br />54" <br />0.2 <br />270 <br />73 <br />STAIR 3 <br />44" <br />0.2 <br />220 <br />73 <br />TOTAL <br />770 <br />219 <br />LIFE SAFETY TAGS <br />DOOR 36" <br />FACTOR <br />PROV. <br />REQ. <br />0.2 <br />180 <br />150 <br />DOOR WIDTH <br />REQUIRED LOAD CAPACITY <br />PROVIDED LOAD CAPACITY <br />OCCUPANT LOAD FACTOR <br />OCCUPANT LOAD BY FLOOR <br />LEVEL P1 - CLINIC <br />DESCRIPTION <br />OF LEVEL <br />OCCUPANCY <br />AREA <br />(SF) <br />OCC. <br />LOAD <br />FACTOR <br />LOAD CALC, BY* <br />N1 <br />N2 <br />PARKING GARAGE <br />GROUP S-2 <br />31,610 <br />200 SF <br />158 <br />159 <br />OFFICE / WORKROOM <br />GROUP B <br />2,378 <br />100 SF <br />24 <br />24 <br />MECH / ELEC <br />GROUP S-1 <br />444 <br />300 SF <br />2 <br />3 <br />TOTAL 34.885 SF 184 186 <br />LEVEL P1 - SCOPE OF WORK <br />DESCRIPTION <br />OF LEVEL <br />OCCUPANCY <br />AREA <br />(SF) <br />OCC. <br />LOAD <br />FACTOR <br />LOAD CALC. BY* <br />N1 <br />N2 <br />OFFICE/WORK ROOM <br />GROUP B <br />2,781 <br />100 SF <br />28 <br />40 <br />TOTAL 2,781 SF 28 40 <br />*LOAD CALCULATION NOTES: <br />N1. NUMBER OF OCCUPANTS PER DESCRIPTION OF LEVEL IS THE SUM OF <br />OCCUPANTS IDENTIFIED PER CUMMULATIVE AREA OF GIVEN OCCUPANCY <br />GROUP USING RELATIVE OCCUPANCY LOAD FACTOR (OLF). <br />N2. NUMBER OF OCCUPANTS PER DESCRIPTION OF LEVEL IS THE SUM OF <br />OCCUPANTS IDENTIFIED PER INDIVIDUAL ROOM OR AREA AS CALCULATED <br />USING SPECIFIC OCCUPANCY LOAD FACTOR (OLF) <br />PLUMBING FIXTURE COUNT - B OCCUPANCY <br />OCCUPANT LOAD <br />REQUIRED PLUMBING <br />FIXTURES <br />PROVIDED PLUMBING FIXTURES <br />LEVEL <br />TOTAL <br />OCL <br />MALE <br />FEMALE <br />WC <br />LAVATORY <br />WC <br />LAVATORY <br />MALE FEMALE <br />MALE I FEMALE <br />MALE FEMALE <br />MALE I FEMALE <br />P1 <br />68 <br />34 <br />34 <br />2 <br />2 <br />1 <br />1 <br />LEVEL1 <br />336 <br />168 <br />168 <br />10 <br />8 <br />16 <br />18 <br />LEVEL 2 <br />281 <br />141 <br />141 <br />8 <br />1 6 <br />1 12 <br />1 14 <br />* KAISER <br />�Ili�j <br />PERMANENTE <br />Project <br />Kaiser Permanente Everett <br />MOB Backfill <br />2929 PINE STREET <br />EVERETT, WA 98201 <br />Prepared for <br />KAISER FOUNDATION <br />HEALTH PLAN, INC. <br />NATIONAL FACILITIES SERVICES <br />POST OFFICE BOX 12916 <br />OAKLAND, CA 94604 <br />Hellmuth, Obata & Kassabaum, Inc. <br />1218 Third Avenue, Suite 500 <br />Seattle, WA 98101 USA <br />t +1 206 493 1771 f +1 206 493 1778 <br />All reproduction & intellectual property rights reserved <br />2022 <br />In Association with <br />Mortenson <br />General Contractor <br />10230 NE Points Drive, Suite 300 <br />Kirkland, WA 98033 <br />Mazzetti <br />MEP + FP Engineering <br />2013 4th Avenue, Suite 200 <br />Seattle. WA 98121 <br />Key Plan <br />Professional Seals <br />4825 <br />REGISTERED <br />ARCHITECT <br />ARR LL W TURNER <br />STATE OF WASHINGTON <br />No. Description Date <br />B BACK FILL ISSUED FOR PERMIT2022/10/14 <br />KP Project No: CAP022566 <br />HOK Project No: 22.05003.00 <br />Sheet Title: <br />LIFE SAFETY PLAN <br />LEVEL P1 <br />Original is 30 x 42. Do not scale contents of this drawing. <br />Sheet Number <br />B1 G10P1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.