1 E DEMOLITION PLAN NOTES • o •
<br />2E 3E 4E 5E 6E 7E 8E 9E KAISER
<br />1. OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS IN CONTRACT PRICE, IF \ PERMAI V E YTE,,,
<br />REQUIRED.
<br />Project
<br />I 2. PROVIDE ALL LABOR AND MATERIALS/EQUIPMENT AS REQUIRED TO COMPLETE Kaiser Permanente Everett
<br />DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED.
<br />3. PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS MOB Bac kf i
<br />ll
<br />FROM EMANATING FROM DEMOLITION / CONSTRUCTION AREA. KEEP AREA CLEAN.
<br />I
<br />4. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE 2929 PINE STREET
<br />POINT IN QUESTION WITH THE ARCHITECT BEFORE PROCEEDING. EVERETT, WA 98201
<br />5. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE
<br />LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL Prepared for
<br />SHALL BE REMOVED. KAISER FOUNDATION
<br />6. DEBRIS REMOVAL SHALL BE PERFORMED USING THE BUILDING FREIGHT HEALTH PLAN, INC.
<br />ELEVATOR. CONTACT THE BUILDING MGMT OFFICE TO OBTAIN SCHEDULE FOR
<br />THE USE OF THE FREIGHT ELEVATORS PRIOR TO SUBMITTING BID. ALL DEBRIS
<br />REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT NATIONAL FACILITIES SERVICES
<br />REQUIREMENTS AND PROCEDURES. POST OFFICE BOX 12916
<br />j 7. ALL MECHANICAL ITEMS, PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING OAKLAND, CA 94604
<br />DOWNLIGHTS & FLUORESCENTS) & SPECIAL EQUIPMENT SHOWN TO BE REMOVED.
<br />SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND RE -USED AS
<br />DIRECTED HEREIN, RETURNED TO BUILDING STOCK OR DISPOSED OF AS
<br />DIRECTED BY BLDG MGMT.
<br />8. THE ELECTRICAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHT
<br />& POWER IN THE SPACE DURING CONSTRUCTION.
<br />I
<br />9. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/ OR REPAIRING ANY
<br />DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS TO EXISTING
<br />CONSTRUCTION IN ELEVATOR LOBBY, PUBLIC CORRIDORS, RESTROOMS OR
<br />TENANT SPACES. REFINISH TO MATCH EXISTING ADJACENT FINISH, OR AS
<br />NOTED HEREIN.
<br />10. NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX
<br />OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED
<br />DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF
<br />SMOKE DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT,
<br />I I IF NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A
<br />FIRST PRIORITY AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE
<br />COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN IT'S INTENDED
<br />PURPOSE. Hellmuth, Obata & Kassabaum, Inc.
<br />1 11. REMOVE TO SOURCE ALL PIPES, VENTS, APPLIANCES OR DRAINS NOT BEING RE- 1218 Third Avenue, Suite 500
<br />j I USED. Seattle, WA 98101 USA
<br />t +1 206 493 1771 f +1 206 493 1778
<br />12. RE -USE OR RELOCATE ALL ABOVE CEILING DUCTWORK, DIFFUSERS, GRILLES,
<br />SPRINKLER PIPES OR OTHER EQUIPMENT, AS REQUIRED FOR PROPER
<br />All reproduction & intellectual property rights reserved
<br />� DISTRIBUTION WITH NEW LAYOUT. 2022 g
<br />I
<br />13. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES AND CONDUIT PERTAINING In Association with
<br />TO DATA/ COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH
<br />I F .; TELEPHONE COMPANIES SERVICE OWNER OR TENANT DATA/ COMMUNICATIONS Mortenson
<br />o
<br />I' "' REPRESENTATIVE AS REQUIRED TO PREVENT NEW CONSTRUCTION DELAYS. General Contractor
<br />10230 NE Points Drive, Suite 300
<br />14. DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS. Kirkland, WA 98033
<br />THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO
<br />I COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DRAWINGS,
<br />15. STAIRWAYS AND EXIT PATHS MUST REMAIN ACCESSIBLE AT ALL TIMES DURING
<br />DEMOLITION.
<br />(I
<br />I 16. REMOVE EXISTING SIGNAGE/GRAPHICS AND STORE FOR RE -USE, WHERE
<br />APPLICABLE.
<br />I
<br />I
<br />it
<br />Mazzetti
<br />MEP + FP Engineering
<br />�I 2013 4th Avenue, Suite 200
<br />I' II DEMOLITION LEGEND Seattle, WA 98121
<br />f Key Plan
<br />I I EXISTING ROOM OR ZONE TO REMAIN, NOT
<br />{ I I I INCLUDED IN THIS SCOPE OF WORK
<br />EXISTING GYP BD PARTITION, DOOR, GLAZING
<br />1 - _ AND FRAMES TO REMAIN
<br />TI - - -�- --m-- EXISTING TO BE REMOVED/DEMO
<br />II I E
<br />I
<br />i
<br />I I j I i
<br />_ 1
<br />I
<br />— -- -- --- - = -- - = _ -_=_ --- ^-- --— -_ -_ -- DEMOLITION PLAN KEYNOTES
<br />EXISTING TOILET, ALL FIXTURES AND ACCESSORIES TO REMAIN
<br />� Professional Seals
<br />D9 EXISTING WALL PHONE TO BE RELOCATED
<br />\ D3 EXISTING COPPER PIPE TO REMAIN 4825
<br />_ _ - .- .�-_ _ - REGISTERED
<br />\ / 11 (i \ / 1l r_. WALAB — I
<br />-_ —
<br />— — — --- — — — — — — — — — — — SC31 I D4 EXISTING FLOORING AND WALL BASE TO REMAIN ARCHITECT
<br />-
<br />II II { II I II II r II
<br />__ f � -- I�------^—� I I f ' I — ------ ----- i I I SC40A I I
<br />FITRM
<br />---- ---
<br />I I \ III { SG NC I I I �J / \ I _ I I i I D5 REMOVE EXISTING DOOR
<br />�I J _-- { _ I{I ARR LL W TURNER
<br />SCO C4A I I—_ -- \(� I ------ ------ ----- D12 L 0 STATE OFWASHINGTON
<br />\� f — — — — — — — �\ o %I a t _ — I �� D6 DEMO PORTION OF WALL FOR NEW DOOR OPENING
<br />11
<br />WRGEN \ / I D1
<br />1
<br />q I D8 D9 SC04 �\i I O-------------------------------------------- DEMO PORTION OF WALL FOR WALL OPENING
<br />ID9
<br />D8 I o REMOVE SINK AND CAP PLUMBING LINE; TERMINATE &CAP
<br />Eii
<br />I j WASTG SGENL _ _ _ _ / \ / \ BOTH WATER SUPPLY LINE AND DRAIN LINE WHERE THEY
<br />No. Description Date
<br />\ � ENTER THE WALL OR THE FLOOR; SEE PLUMBING
<br />SC03 \ SC04A I / n \ DRAWINGS FOR EXTENT OF DEMOLITION MOB BACK FILL ISSUED FOR PERMIT 2022/10/14
<br />i — — — \ — — — — — — — — — — —J I — — — —D10 O REMOVE CASEWORK AND SINK; TERMINATE & CAP BOTH
<br />I I � I
<br />— — — — WATER SUPPLY LINE AND DRAIN LINE WHERE THEY ENTER
<br />�;..
<br />F I ,,j I I THE WALL OR THE FLOOR; SEE PLUMBING DRAWINGS FOR
<br />D6 SCART ( I I I I OPROV I I DISPIL D12 I EXTENT OF DEMOLITION
<br />SC03D I I I \ WRGEN � \ I SC32 � I SC40B j
<br />1
<br />SEQGN I I SSTSU \71
<br />I D10 REMOVE FLOORING AND WALL BASE
<br />SC003B I i I � — SC05 � � � SC04B EDGE OF FLOORING TO BE DEMOED
<br />E _FRY
<br />D12 — — I I D12 D10 D10 =� ` OirE� i i D12 REMOVE CASEWORK AND/OR FURNISHING
<br />D10 I
<br />I _ SGENL D11
<br />D13 REMOVE EXISTING FIRE EXTINGUSHER II I I D12 II I I �
<br />SC03A i { I D10
<br />-------�I I 64"
<br />o"
<br />— — — —� — -----
<br />\ SGENL — ALIGN
<br />II D12 II \ SCOOC2A r q {
<br />D2 7III GENL II SGENL I SBUL�— —
<br />03C SC03H SC03E —
<br />i
<br />r---I-i--- ----� — — I SLINC
<br />I ----- --------I r--SC03 D10 III / / I S
<br />�
<br />I D12 D10 D10
<br />I D9rr
<br />I \�I II I I
<br />I I
<br />I II II I I
<br />_ - --- -- -- — — -- - --- —— I _ ]I I I I—
<br />OGENL
<br />,:
<br />EXSLN
<br />SC35 JT±=
<br />F — jpEXSLN S»v,C`1 L
<br />SAG€N —
<br />13
<br />-Scan-— — SG3 — — — -
<br />1 sC01 I I I I I I I
<br />�JI I WS EN \
<br />D8 _ I ;COF \ OGENL
<br />D - _
<br />® 10
<br />t_ l I -H D10 SC06 T I T I I D10
<br />F
<br />I D12 I I D10 I I I I I I I I I I I y\
<br />D12 I I I I I -L_- KIP Project No: CAP022566
<br />II — — — — — — — __ _ _ _ _ _ — — D9 I I I I D I I {, D9 \ HOK Project No: 22.05003.00
<br />— — — I F I I I I� \� . y.
<br />----------- �I I � JI Sheet Title:
<br />DEMO PLAN - LEVEL
<br />P1 - AREA E
<br />Q
<br />M
<br />0)
<br />Original is 30 x 42- Do not scale contents of this drawing.
<br />DEMO PLAN - LEVEL P1 - AREA E Sheet Number
<br />N 1 N 1/4" = 1'-0"
<br />0
<br />N B1 AD10P1
<br />
|