Laserfiche WebLink
Q <br />M <br />O <br />N <br />0 <br />N <br />N <br />O <br />N <br />1E 2E 3E 4E 5E <br />i <br />I <br />D12 i I \ <br />r -- -- <br />(D11 WK ST---- OS223E °S2 4t - <br />____� S222 <br />o B D10 � <br />I I D4 <br />c7 <br />----� Q <br />I <br />I <br />--- WK STA �� CORRIDOR <br />S221A j D4 S20005 <br />i <br />D10 l <br />II <br />COPY / PRINT <br />L-- S220 'f <br />Ficp 0 F F-IC,E <br />S- <br />D4 <br />WK STA <br />A <br />I <br />i <br />I <br />- <br />OFFICE <br />S218 <br />D4 <br />I ----� OFFICE <br />S219 I I , <br />CORRIDOR <br />t D12 i D10 i /S20OC4 <br />_—__J S2001-11 <br />---T ----- --1 <br />I I I <br />I I D12 D4 <br />u----1--------- -- <br />i I `� <br />OFFICE AUDIOLOGY BOO I <br />II I S216 1 I 52;8 <br />u---- I <br />OFFICE <br />S217- <br />I <br />\ WAIT <br />COPY/PRINTI I D4 S <br />I S215 <br />) <br />4 <br />--------- i fir''DE <br />,3 IIP211 <br />DIVE STOR <br />D12 itD12 i I D12 itDS212I <br />SEC <br />E;]� D11 _"Ji <br />D4 ;;ORRIDOR <br />S200C3 <br />EI_EV I <br />���vE4 <br />C a --- <br />uti(�I�D <br />S20OC2 <br />L� <br />I <br />r <br />CORRIDOR <br />S200C1 <br />IT ! VEND <br />S2{.6A <br />LAB <br />S236 <br />WK STA <br />S235 - <br />EXAM,,; <br />S26G <br />EXAM <br />S261 <br />7E 8E 9E <br />.m <br />ir <br />t +N e............ _.. r <br />}, <br />3 ! <br />i <br />I I ' <br />r <br />1=, ICE 3 <br />---- S0 -- OrF=CE OFFICE <br />S231 I ( S254 <br />e <br />i <br />I <br />I I I <br />I II I <br />I j II <br />VVK STA 'YK STA WK STr". <br />S229E S229G S2291 S253 <br />tEXPO <br />�- WK STA �; WK S I A 3229 i C_FFCE <br />S229 S229H 253 <br />I I I <br />I I I <br />o <br />"::-01-?RIDOR <br />S20006 <br />T II_ET <br />g 523.E <br />l <br />1 ; <br />S252 <br />M <br />I I <br />I <br />WK STA <br />•. S275L' I <br />SiOR <br />CORRIDOR <br />S20O(D'9 <br />Li.bbY <br />S260A <br />DEMO PLAN LEVEL 2 - AREA E <br />1/4" = 1'-0" <br />CORRIDOR <br />_'00C1 A <br />77FI -, <br />S200CJA <br />EOELC, <br />EXIS <br />ELEC <br />S2�OOCw; <br />I <br />of <br />• <br />DEMOLITION PLAN NOTES <br />1 KAISER <br />PERMANENTE.� <br />1. <br />OBTAIN DEMOLITION PERMITS AND INCLUDE ALL COSTS IN CONTRACT PRICE, IF <br />-� <br />REQUIRED. <br />Project <br />2. <br />PROVIDE ALL LABOR AND MATERIALS/EQUIPMENT AS REQUIRED TO COMPLETE <br />Kaiser Permanente Everett <br />DEMOLITION AND REMOVAL OF ALL ITEMS AS INDICATED. <br />MOB Backfill <br />3. <br />PROVIDE STRICT CONTROL OF JOB CLEANING AND PREVENT DUST AND DEBRIS <br />FROM EMANATING FROM DEMOLITION / CONSTRUCTION AREA, KEEP AREA CLEAN. <br />2929 PINE STREET <br />4. <br />IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE <br />EVERETT, WA 98201 <br />POINT IN QUESTION WITH THE ARCHITECT BEFORE PROCEEDING. <br />5. <br />AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE <br />Prepared for <br />LEFT IN "BROOM CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL <br />p <br />SHALL BE REMOVED. <br />KAISER FOUNDATION <br />6. <br />DEBRIS REMOVAL SHALL BE PERFORMED USING THE BUILDING FREIGHT <br />HEALTH PLAN, INC. <br />ELEVATOR. CONTACT THE BUILDING MGMT OFFICE TO OBTAIN SCHEDULE FOR <br />THE USE OF THE FREIGHT ELEVATORS PRIOR TO SUBMITTING BID, ALL DEBRIS <br />NATIONAL FACILITIES SERVICES <br />REMOVAL SHALL BE PERFORMED IN ACCORDANCE WITH BUILDING MANAGEMENT <br />REQUIREMENTS AND PROCEDURES. <br />POST OFFICE BOX 12916 <br />OAKLAND, CA 94604 <br />7. <br />ALL MECHANICAL ITEMS. PLUMBING FIXTURES, LIGHT FIXTURES (INCLUDING <br />DOWNLIGHTS & FLUORESCENTS) & SPECIAL EQUIPMENT SHOWN TO BE REMOVED, <br />SHALL BE CLEAN AND FREE OF DEFECTS, PROTECTED, SAVED AND RE -USED AS <br />DIRECTED HEREIN, RETURNED TO BUILDING STOCK OR DISPOSED OF AS <br />DIRECTED BY BLDG MGMT. <br />& <br />THE ELECTRICAL CONTRACTOR SHALL FURNISH A SYSTEM OF TEMPORARY LIGHT <br />& POWER IN THE SPACE DURING CONSTRUCTION. <br />9. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/ OR REPAIRING ANY <br />DAMAGE CAUSED BY HIM OR HIS SUBCONTRACTORS TO EXISTING <br />CONSTRUCTION IN ELEVATOR LOBBY, PUBLIC CORRIDORS, RESTROOMS OR <br />TENANT SPACES. REFINISH TO MATCH EXISTING ADJACENT FINISH, OR AS <br />NOTED HEREIN. <br />• <br />10. <br />NO EXISTING SMOKE DETECTOR, PUBLIC ADDRESS SPEAKER, FIRE ALARM BOX <br />OR SIMILAR DEVICE, INCLUDING THE ASSOCIATED WIRING SHALL BE DAMAGED <br />DURING DEMOLITION AND SUBSEQUENT CONSTRUCTION. RELOCATION OF <br />SMOKE DETECTORS. PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, <br />IF NECESSITATED BY NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A <br />FIRST PRIORITY AND PER THE PLANS. NO ACTIVE SMOKE DETECTOR SHALL BE <br />COVERED OR OTHERWISE REMOVED OR USED FOR OTHER THAN IT'S INTENDED <br />PURPOSE. <br />Hellmuth, Obata & Kassabaum, Inc. <br />1218 Third Avenue, Suite 500 <br />11. <br />REMOVE TO SOURCE ALL PIPES, VENTS, APPLIANCES OR DRAINS NOT BEING RE- <br />Seattle, WA 98101 USA <br />USED. <br />t +1 206 493 1771 f +1 206 493 1778 <br />12. <br />RE -USE OR RELOCATE ALL ABOVE CEILING DUCTWORK, DIFFUSERS, GRILLES, <br />SPRINKLER PIPES OR OTHER EQUIPMENT, AS REQUIRED FOR PROPER <br />All reproduction & intellectual property rights reserved <br />DISTRIBUTION WITH NEW LAYOUT. <br />2022 <br />In Association with <br />13. <br />REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES AND CONDUIT PERTAINING <br />TO DATA/ COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH <br />Mortenson <br />TELEPHONE COMPANIES SERVICE OWNER OR TENANT DATA/ COMMUNICATIONS <br />General Contractor <br />REPRESENTATIVE AS REQUIRED TO PREVENT NEW CONSTRUCTION DELAYS. <br />10230 NE Points Drive, Suite 300 <br />14. <br />DEMOLITION IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON DRAWINGS. <br />Kirkland, WA 98033 <br />THE INTENT IS TO INDICATE THE GENERAL SCOPE OF DEMOLITION REQUIRED TO <br />COMPLETE THE WORK IN ACCORDANCE WITH THE CONTRACT DRAWINGS. <br />15. <br />STAIRWAYS AND EXIT PATHS MUST REMAIN ACCESSIBLE AT ALL TIMES DURING <br />DEMOLITION. <br />16. <br />REMOVE EXISTING SIGNAGE/GRAPHICS AND STORE FOR RE -USE, WHERE <br />APPLICABLE. <br />DEMOLITION LEGEND <br />EXISTING ROOM OR ZONE TO REMAIN, NOT <br />INCLUDED IN THIS SCOPE OF WORK <br />EXISTING GYP BD PARTITION, DOOR, GLAZING <br />AND FRAMES TO REMAIN <br />EXISTING TO BE REMOVED/DEMO <br />DEMOLITION PLAN KEYNOTES <br />D1 EXISTING TOILET, ALL FIXTURES AND ACCESSORIES TO <br />REMAIN <br />D2 EXISTING WALL PHONE TO BE RELOCATED <br />D3 EXISTING COPPER PIPE TO REMAIN <br />D4 EXISTING FLOORING AND WALL BASE TO REMAIN <br />D5 REMOVE EXISTING DOOR <br />D6 DEMO PORTION OF WALL FOR NEW DOOR OPENING <br />D7 DEMO PORTION OF WALL FOR WALL OPENING <br />pg REMOVE SINK AND CAP PLUMBING LINE; TERMINATE & CAP <br />BOTH WATER SUPPLY LINE AND DRAIN LINE WHERE THEY <br />ENTER THE WALL OR THE FLOOR; SEE PLUMBING <br />DRAWINGS FOR EXTENT OF DEMOLITION <br />pg REMOVE CASEWORK AND SINK; TERMINATE & CAP BOTH <br />WATER SUPPLY LINE AND DRAIN LINE WHERE THEY ENTER <br />THE WALL OR THE FLOOR; SEE PLUMBING DRAWINGS FOR <br />EXTENT OF DEMOLITION <br />D10 REMOVE FLOORING AND WALL BASE <br />D11 EDGE OF FLOORING TO BE DEMOED <br />D12 REMOVE CASEWORK AND/OR FURNISHING <br />D13 REMOVE EXISTING FIRE EXTINGUSHER <br />Mazzetti <br />MEP + FP Engineering <br />2013 4th Avenue, Suite 200 <br />Seattle, WA 98121 <br />Key Plan <br />�l <br />Professional Seals <br />4825 <br />REGISTERED <br />ARCHITECT <br />ARR LL W TURNER <br />STATE OF WASHINGTON <br />No. Description Date <br />MOB BACK FILL ISSUED PERMIT 20 10 14 <br />KIP Project No: CAP022566 <br />HOK Project No: 22.05003.00 <br />Sheet Title: <br />DEMO PLAN - LEVEL 2 <br />- AREA E <br />Original is 30 x 42. Do not scale contents of this drawing. <br />Sheet Number <br />