CONTRACTOR <br /> ENPHASE IGMEM IQ8 and IQ8+ Microinverters ELECTRICAL SYSTEMS <br /> SOLUTIONS INC <br /> INPUT DATA(DC1 108-60-2-US 10 BPLUS-72-2-US <br /> PO BOX 16452, SEATTLE, <br /> Commonly used module pairings' W 235-350 235-440 WASHINGTON, 98116 <br /> Module compatibility 60-cell/120 half-cell 60-cell/120 half-cell and 72-cell/144 half-cell <br /> PHONE -(206)963-2999 <br /> MPPT voltage range 27-37 29-45 LIC. NO. - EC ELECTSS902JN <br /> Operating range ° 25-48 25-58 <br /> Min/max start voltage ° 30/48 30/58 <br /> Max input DC voltage V 50 60 <br /> Max DC current'[module Isc] A 15 <br /> Overvoltage class DC port II <br /> DC port backfeed current mA 0 <br /> = PV array configuration 1x1 Ungrounded array:No additional DC side protection required:AC side protection requires max 20A per branch circuit <br /> OUTPUT D108-60-2-US 108PLUS-72-2-US <br /> Peak output power VA 245 300 <br /> Max continuous output power VA 240 290 <br /> Nominal(L-L)voltage/range' V 240/211-264 <br /> Max continuous output current A 1.0 1.21 <br /> Nominal frequency Hz 60 <br /> IQ8 and IQ8+ Microinverters Extended frequency range Hz 50-68 PROJECT NAME &ADDRESS <br /> Max units per 20A(L-L)branch circuit' 16 13 ELIZABETH CALSYN <br /> Our newest IQ8 Microinverters are the industry's first micro grid-forming,software- Total harmonic distortion <5i <br /> defined microinverters with split-phase power conversion capability to convert DC Overvoitageclass ACport III 216 MADISON ST, <br /> power to AC power efficiently.The brain of the semiconductor-based microinverter Easy to install EVERETT, WA 98203 <br /> is our proprietary application-specific integrated circuit(ASIC)which enables the Lightweight and compact with AC port backfeed current mA 30 <br /> APN #: 00392000000109 <br /> microinverter to operate in grid-tied or off-grid modes.This chip is built in advanced plug-n-play connectors Power factor setting 1.0 <br /> 55nm technology with high speed digital logic and has super-fast response times Power Line Communication Grid-tied power factor(adjustable) 0.85 leading-0.85 lagging AHJ: CITY OF EVERETT <br /> to changing loads and grid events,alleviating constraints on battery sizing for home (PLC)between components Peak efficiency °i 97.5 97.6 <br /> energy systems. UTILITY: PUD <br /> • Faster installation with simple CEC weighted efficiency °r 97 97 <br /> two-wire cabling Night-time power consumption mW 60 SYSTEM DETAILS <br /> F011kiphase -I MECHANICAL D,TA DC SIZE:7.665 KW DC-(STC) <br /> AC SIZE:6.090 KW AC <br /> High productivity and reliability <br /> Ambient temperature range -40°C to+60°C(-40°F to 1401F) (21)URECO FBM40OMFG-BB <br /> 25 Produce power even when the Relative humidity range 4%to 100%(condensing) (21)ENPHASE IQ8PLUS-72-2-US[240V] <br /> year limned grid is down <br /> warranty <br /> DC Connector type MC4 <br /> • More than one million cumulative <br /> Part of the Enphase Ener System.IQ8 Series IQ8 Series Microinverters redefine reliability Dimensions(HxWxD) 212 mm(8.3'7 x 175 mm(6.9'7 x 30.2 mm(1.2'7 <br /> P sv vs v hours of testing REVISIONS <br /> Microinverters integrate with the Enphase IQ standards with more than one million Weight 1.08 kg(2.38 1 bs) <br /> Battery.Enphase 10Gateway.and the Enphase cumulative hours of power-on testing. Class 11double-insulated <br /> App monitoring and analysis software. enabling an Industry-leading limitedwarranty enclosure Cooling Natural convection-nofans REV DESCRIPTION DATE <br /> of up to 25 years. <br /> Optimized for the latest high- Approved for wet locations yes <br /> powered PV modules Acoustic noise at 1 m <60 dBA <br /> Pollution degree PD3 <br /> Microgrid-forming Enclosure Class II double-insulated.corrosion resistant polymeric enclosure <br /> CERTIFIED Complies with the latest Environ.category/W exposure rating NEMA Type 6/outdoor <br /> advanced grid support COMPLIANCE <br /> Connect PV modules quickly and easily to IQ8 Series Microinverters are UL Listed as Remote automatic updates for CA Rule 21(UL 1741-SA).UL 62109-1.UL1741AEEE1547.FCC Part 15 Class B.ICES-0003 Class B.CAN/CSA-C22.2 NO.107.1-01 SHEET TITLE <br /> IQ8Series Microinverters using the included PV Rapid Shut Down Equipment and conform the latest grid requirements RESOURCE <br /> Q-DCC-2 adapter cable with plug-n-play MC4 with various regulations.when installed Certifications This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC 2014.NEC 20T7.and NEC 2020 section <br /> connectors. according to manufacturer's instructions. Configurable to support a wide 690.12 and C22.1-2018 Rule 64-218 Rapid Shutdown of PV Systems.for AC and DC conductors.when installed according to <br /> range of grid profiles manufacturer's instructions. DOCUMENT <br /> ©2021 Enphase Energy.All rights reserved.Enphase.the Enphase logo.I08 microinverters. Meets CA Rule 21(UL 1741-SA) (1)No enforced DC/AC ratio.See the compatibility calculator at https://Iink.enphase.com/ <br /> and other names are trademarks of Enphase Energy.Inc.Data subject tochange. requirements module-compatibility(2)Maximum continuous input DC current is 10.6A(3)Nominal voltage DRAWN DATE 4/15/2023 <br /> range can be extended beyond nominal if required by the utility.(4)Limits may vary.Refer to <br /> IQ85P-DS-0002-01-EN-US-2021-10-19 local requirements to define the number of microinverters per branch in your area. IQBSP-DS-0002-01-EN-US-2021-10-19 DRAWN BY PCAD <br /> SHEET NUMBER <br /> R-02 <br />
The URL can be used to link to this page
Your browser does not support the video tag.