NEW PHOTOVOLTAIC ROOF MOUNTED SYSTEM - 7.67 KW DC/6.090 KW AC CONTRACTOR <br /> 216 MADISON ST, EVERETT, WA 98203 <br /> NEW PV SYSTEM SPECIFICATIONS SHEET INDEX ELECTRICAL SYSTEMS <br /> SYSTEM SIZE: DC SIZE:7.665 KW DC-(STC) LEGEND SOLUTIONS INC <br /> AC SIZE:6.090 KW AC ---- -PROPERTY LINE PV-01 COVER PAGE PO BOX 16452, SEATTLE, <br /> MODULE: (21)URECO FBM40OMFG-BB o FENCE LINE PV-02 SITE PLAN <br /> INVERTER: (21)ENPHASE IQ8PLUS-72-2-US[240V] PV-03 ATTACHMENT PLAN&DETAILS WASHINGTON, 98116 <br /> PV-04 ELECTRICAL DIAGRAM PHONE-(206)963-2999 <br /> APPLICABLE CODES MADISON ST PV-05 NOTES LIC. NO. —EC ELECTSS902JN <br /> ALL WORK SHALL CONFORM TO THE FOLLOWING CODES: PV-06 WARNING LABELS <br /> 2018 WASHINGTON STATE BUILDING CODE PV-07 STRING DIAGRAM <br /> 2018 WASHINGTON STATE RESIDENTAL CODE R-01 —>R-07 I RESOURCE DOCUMENT <br /> 2018 WASHINGTON STATE FIRE CODE <br /> 2018 INTERNATIONAL BUILDING ADMINISTRATIVE CODE (IBAC) <br /> 2018 INTERNATIONAL ENERGY CONSERVATION CODE(IECC) (E) UTILITY METER <br /> 2018 INTERNATIONAL EXISTING BUILDING CODE(IEBC) (OVERHEAD SERVICE) <br /> 2018 INTERNATIONAL SWIMMING POOL AND SPA CODE(ISPSC) METER#: 15248317 <br /> 2020 WASHINGTON STATE ELECTRICAL CODE NOTES: <br /> AS ADOPTED BY CITY OF EVERETT 1.ROOF ACCESS POINT SHALL NOT BE LOCATED <br /> 53'-6" _ IN AREAS THAT REQUIRE THE PLACEMENT OF <br /> DESIGN CRITERIA GROUND LADDERS OVER OPENINGS SUCH AS <br /> ROOF SURFACE TYPE: COMPOSITE SHINGLEQ WINDOWS OR DOORS,AND LOCATED AT <br /> I= I (E)MAIN SERVICE PANEL STRONG POINTS OF BUILDING CONSTRUCTION <br /> ROOF FRAMING:2"X4"TRUSS @ 24"OC ch �: <br /> BUILDING STORY:TWO STORY (E)GARAGE IN I IN LOCATIONS WHERE THE ACCESS POINT DOES <br /> GROUND SNOW LOAD: 20 PSF I - I NOT CONFLICT WITH OVERHEAD OBSTRUCTIONS <br /> WIND SPEED: 110 MPH D SUCH AS TREE LIMBS,WIRES OR SIGNS. PROJECT NAME &ADDRESS <br /> WIND EXPOSURE: B 2.STRUCTURES,PATIO COVERS,AND/OR ELIZABETH CALSYN <br /> RISK CATEGORY: II I ADDITIONS BUILT WITHOUT PERMITS TO BE <br /> ROOF ACCESS POINT RESOLVED BY A SEPARATE PERMIT. 216 MADISON ST, <br /> 20'-3" <br /> VICINITY MAP EVERETT, WA 98203 <br /> PROJECT NOTES (E)HOUSE APN#: 00392000000109 <br /> 1.1.1 THIS PHOTOVOLTAIC(PV)SYSTEM SHALL COMPLY WITH THE "M�� P' AHJ: CITY OF EVERETT <br /> RELEVANT YEAR OF THE NATIONAL ELECTRIC CODE(NEC),ALL <br /> MANUFACTURER'S LISTING AND INSTALLATION INSTRUCTIONS, (21)URECO FBM40OMFG—BB UTILITY: PUD <br /> AND THE RELEVANT CODES AS SPECIFIED BY THE AUTHORITY MODULES WITH ENPHASE 4'-7" SYSTEM DETAILS <br /> HAVING JURISDICTION'S(AHJ)APPLICABLE CODES. IQ8PLUS-72-2—US [240V] <br /> 1.1.2 THE UTILITY INTERCONNECTION APPLICATION MUST BE UNDER EACH MODULE (E) DECK ' *' DC SIZE:7.665 KW DC-(STC) <br /> r / AC SIZE:6.090 KW AC <br /> APPROVED AND THE PV SYSTEM MUST BE INSPECTED PRIOR TO (21)URECO FBM400MFG-BB <br /> OPERATION ° ! (21)ENPHASE IQ8PLUS-72-2-US[240V] <br /> 1.1.3 ALL PV SYSTEM COMPONENTS; MODULES, (E)SHED <br /> S <br /> UTILITY-INTERACTIVE INVERTERS,AND SOURCE CIRCUIT <br /> COMBINER BOXES ARE IDENTIFIED AND LISTED FOR USE IN ,�'t., r ; REVISIONS <br /> PHOTOVOLTAIC SYSTEMS AS REQUIRED BY NEC AND OTHER Lo R . <br /> GOVERNING CODES (E) FENCE REV DESCRIPTION DATE <br /> 1.1.4 ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL <br /> BUILDING CODE. IF EXPOSED TO SUNLIGHT, IT SHALL BE UV v" <br /> RESISTANT.ALL PLAQUES AND SIGNAGE WILL BE INSTALLED AS ' <br /> REQUIRED BY THE NEC AND AHJ. <br /> L, SATELLITE VIEW <br /> G a R Ka°M1Ma„ o:,M1 <br /> SCOPE OF WORKy�aoaQ► <br /> ,p,Ea R„ , ifr° SHEET TITLE <br /> -111—Kift <br /> ACTOR <br /> LE FOR THE <br /> AND <br /> SPONSI <br /> SPECIFICATIONS OIT EEGR D-TIED PHOTOVOLTAIC YSTEM. o”p oN R�Rd Md°�p ® R°d'°9E°e='RC a"° & COVER PAGE <br /> olmmmm” <br /> THE CONTRACTOR WILL BE RESPONSIBLE FOR COLLECTION OF <br /> 1AM1",o"BT11 1.1 <br /> EXISTING ONSITE CONDITIONS TO DESIGN, SPECIFY,AND oa wgap <br /> �. <br /> INSTALL THE ROOF-MOUNTED PHOTOVOLTAIC SYSTEM p DRAWN DATE 4/15/2023 <br /> DETAILED IN THIS DOCUMENT <br /> DRAWN BY PCAD D <br /> a,M1alp , ,n.s� ,"M1NaE sa,a"„p <br /> N Ru,z EVERGREEN o <br /> R°a,"ep& �,g,°°aM,M1°, 9 SHEET NUMBER <br /> +a��p ' 0 oQ,e®E°e.g,ea"a=,a"Na,� <br /> PROPERTY PLAN 53'-6" o FRaei"RG �Iaa, °.° G��=�"=o <br /> PV-01 <br /> SCALE:1"-30'-0' 2 <br /> 0®� o,xon Eos Gavl ��LL,nber'E✓e<<_—`— _ <br /> iasryindmn Blsto 'Elemenfary3eM1ool —�` <br />
The URL can be used to link to this page
Your browser does not support the video tag.