My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
216 MADISON ST 2023-07-13
>
Address Records
>
MADISON ST
>
216
>
216 MADISON ST 2023-07-13
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/13/2023 1:39:25 PM
Creation date
7/13/2023 11:13:53 AM
Metadata
Fields
Template:
Address Document
Street Name
MADISON ST
Street Number
216
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EVERETT SUBMITTAL INSTRUCTIONS:Email application to PermitServices@everettwa.gov or drop off at 3200 Cedar Street 2nd Floor Drop Box <br /> WASHINGTONCONTACT INFORMATION:(P)425-257-88101(E)PermdServices@everettwa.gov I(W)everettwa.gov/permits <br /> PROJECT SITE INFORMATION <br /> PROJECT ADDRESS216 Madison St PARCEL#: <br /> BUILDING TYPE: E)SFR-DETACHED ❑SFR-ATTACHED/TOWNHOUSE [3DUPLEX <br /> CONTACT INFORMATION <br /> OWNER NAME Elizabeth Calsyn <br /> CONTRACTOR NAME:Electrical SyStems Solutions, Inc <br /> CONTRACTOR LIC. REQUIRED:ELECTSS902JN ICITY OF EVERETT BUSINESS LIC. REQUIRED:65809 <br /> PRIMARY CONTACT: ❑OWNER 21CONTRACTOR ❑OTHER(Please Specify) <br /> CONTACT NAME:RICH BARRIENTOS ICONTACT PHONES-923-937$ <br /> CONTACT EMAIL:rich@elessinc.com <br /> SOLAR PANEL APPLICATION INFORMATION <br /> PV SYSTEM DESCRIPTION include manufacturer and model,#of PV modules and inverters): <br /> Module:URECO(FBM400MFG-BB)-21 PV Inverter:ENPHASE(I138PLUS-72-2-US)-21 inverters <br /> BUILDING PERMIT CHECKLIST <br /> DETERMINE IF YOUR PROJECT QUALIFIES FOR AN OVER-THE-COUNTER BUILDING PERMIT: <br /> If you answer yes to all of the below questions, the project qualfies for an over-the-counter building permit. YES NO <br /> 1. PV system is designed and proposed for a detached one-or two-family dwelling or townhouse not more than three <br /> stories above grade or detached accessory structure that is code compliant to setbacks and height, or code allows ❑✓ ❑ <br /> expansion of nonconformity for solar modules. IRC 101.2 <br /> 2. Modules on pitched roofs do not exceed the highest point of the roof unless approved by the local jurisdition. ✓❑ ❑ <br /> 3. Rooftop is made from lightweight material such as a single layer of composition shingles, metal roofing, lightweight ❑ <br /> masonry,or cedar shingles. 21 <br /> 4.The installation shall comply with the manufacturer's instructions. [IRC M2302.2] ❑✓ ❑ <br /> 5. The installation shall meet the requirements of NFPA 70 National Electric Code, and all required electrical permit(s)must 11be obtained from the Authority having Jurisdiction to administer the electrical code. [IRC M2302.21 <br /> El 6.The installation shall meet the requiremetns of the Intemational Fire Code as amended by WA State. [IRC M2302.21 ✓❑ ❑ <br /> 7.The PV system is designed for the wind speed of the local area, and will be installed per the manufacturer's 0 ❑ <br /> specifications. [IRC M2302.2.1(1)1 <br /> 8.The ground snow load does not exceed 70 pounds per square foot. [IRC M2302.2.1(1)] ✓❑ ❑ <br /> 9. The total dead load of modules, supports,mountings, raceways, and all other appurtenances weigh no more than four ❑ <br /> pounds per square foot. [IRC M2302.2.1(3)]. Enter total dead load of system(lbs/sq.ft.): <br /> 10.To address uplift, modules are mounted no higher than 18"above the surface of the roofing to which they are affixed. a ❑ <br /> [IRC M2302.2.1(4)] <br /> 11. Supports for solar modules are installed to spread the dead load across as many roof-framing members as needed to 11ensure that no point load exceeds fifty(50)pounds. [IRC M2302.2.1(5)] <br /> 21 12.The photovoltaic modules and supporting structure shall be constructed of noncombustible materials or fire-retardant E]treated wood equivalent to that required for the roof construction. [IRC M2302.2.1] <br /> El 13. Roof and wall penetrations shall be flashed and sealed to prevent entry of water, rodents, and insects. [IRC M2302.2.2] Q ❑ <br /> 14. PV modules are listed and leveled with a fire classification in accordance with UL 1703. [IRC M2302.2.3] [) ❑ <br /> Comments: <br /> PLEASE FILL OUT A CITY OF EVERETT BUILDING PERMIT APPLICATION IF YOU QUALIFY FOR AN OTC BUILDING PERMIT. <br /> City of Everett Official Use Only <br /> S CIATED BUILDING PERMIT# <br /> Q <br />
The URL can be used to link to this page
Your browser does not support the video tag.