Laserfiche WebLink
Yll <br /> 10 5 14 10 5 15 <br /> x x x x LEGEND <br /> - - - - - - - - - - - - G f r* 48OV, 3P4W RECEPTACLE CROUSE HINDS <br /> o x — — ATCH LIN - FOR CONTINU TION S E HEFT 1 14 lac 0 — — x-- <br /> > <br /> — — #ARE3422 <br /> w � o <br /> o �x o GENERAL NOTES <br /> 13G13 X <br /> 6 UPPLY FAN 1 <br /> w o OHP x <br /> L I1. CONDUIT: 1/2" EMT MINIMUM, UNLESS OTHERWISE <br /> 12613 X NOTED. USE COMPRESSION CONNECTORS & COUPLINGS. <br /> o o VFD-11-14 o AHU—1 qsa-a,s <br /> 0X72"B 30 X72" I VACUUM UNT <br /> Q o0 o l.0 A. 3. <br /> FLC.20A. SOORPM 2. CONDUCTORS SHOWN: #12 AWG, STRANDED COPPER, <br /> o <br /> BEH 30-1 4540 INSULATION TYPE THHN/THWN, UNLESS OTHERWISE <br /> OfKOf fKOf MOf o o �m TW330 SUPV AREA 1/2" 3- 0 NOTED. <br /> _ Z z <br /> MCC-4V33-3H14/B1 Em Esta n 3. WHERE SPECIFIED, PROVIDE A SEPARATE DEDICATED <br /> MCC-4V33-31-14 = <br /> _ Mcc-4v33-3H14/A3a sToc" NEUTRAL FOR EACH DEDICATED CIRCUIT. NEUTRALS <br /> o o - <br /> MCC-4V33-3T! 30KVA ______ x SHALL BE WHITE WITH A TRACER COLORED SAME AS <br /> �_ <br /> VF VFD X—X—X—X ASSOCIATED PHASE. <br /> -- --- ---J MCC-4V33-31-H4/133 <br /> Es' sw sw sw x o o I El 4. COLOR CODE CONDUCTORS: IDENTIFY CONDUCTORS <br /> Tx „„ xxxx •-I VFD-1H14-1 MCC- v33-31-14/62 SPE VAC CER WHICH DO NOT HAVE APPROPRIATELY COLORED <br /> INSULATION WITH COLOR TAPE WHEREVER CONDUCTORS <br /> 4.2HP ARE ACCESSIBLE. IDENTIFY INSULATED GROUND <br /> AHU 2 7 7 CONDUCTORS IN ACCORDANCE WITH THE LATEST NEC <br /> OAHU 4 �® HU-3 (USING TAPE). COLOR CODE AS FOLLOWS: <br /> SUPPLY FAN 2 <br /> 7.SHP j SUPPLY FAN 4 SUP LY FAN 3 O x r <br /> off 51-P ° 208YBLACK <br /> 120V BROWN 277V <br /> U 58L a i [°] A4 (LEFT BUS N PNL) BLACK BROWN <br /> I ❑ I B4 (CENTER BUS IN PNL) RED ORANGE <br /> 1 17 3/4H ST COL CO (RIGHT BUS IN PNL) BLUE YELLOW <br /> � ❑ 1 1 � � , BHEC 382769 of � G h NEUTRAL WHITE GRAY <br /> 1E1n Esaa-1 iE117 Esa6-2 EQUIPMENT GROUND GREEN GREEN <br /> 3/4"C,3#8, J ° 2HP ISC SANDER ❑ s a ISOLATED GROUND GRN/YEL* GRN/YEL* <br /> o BEHC 766 w *GREEN WITH YELLOW TRACER <br /> 50-1 a LJ 1 HP. BELT SANDER N <br /> x 5. DYMO LABEL EACH RECEPTACLE, JUNCTION BOX, SWITCH <br /> w N om N ° BEHC 382763 AND EQUIPMENT WITH CIRCUIT SOURCE IDENTIFICATION. <br /> CLEAN, SEAL AND PAINT TW330 ~ CLEAN, SEAL AND PAINT TW33 a ° <br /> v z <br /> zo Q 4613 a 4630 CD 6. POST NEW OR REVISED PANEL SCHEDULES UPON <br /> ®BUSSWAY 4V33-31-13 x LOW a <br /> z a 50A-3P,480V 34 TRENCH �m x NIT Z COMPLETION OF JOB. <br /> z ------ ------- --------------------- - --------- ----- N 3/41- DRILL PR SS o zo 7> EXHAUST FAN-2 FOR AHU-2 LOCATED ON ROOF AT 1-14. <br /> vBEHC 382758 " SEE DRAWING 40-033-E546. EXHAUST FAN 3 FOR AHU-3 <br /> o <br /> EL3( _ ?' IS LOCATED ON ROOF. <br /> -- LA T <br /> ------------------ --- --------- --------- - o _ _ o _ <br /> a J IS ALSO REFERENCED AS 4V33-iH13 <br /> 0 3 ° o V33- H 14.5 (S E D G 40- - 67) & <br /> 3/4"C.-3#10 SPENCER #10 L°J O �a <br /> a VACUUMNI SB_62D- oA a REFERENCE DRAWINGS <br /> VAC > & 1#10 GND 00 DONE1 1,, UNIT <br /> 20HP,46OV, <br /> BEHC 3-1 ORPM SEE DRAWING 40-033-TNE117 FOR ADDITIONAL <br /> BEHC 30-11 0 <br /> 09%£ <br /> 1/2" F GS 4 #1 THHN TO BUS DUCT ELECTRICAL INSTALLATION IN THIS AREA. <br /> e ev1Dd HONEYWEL ^^ <br /> CONTROL �� MM <br /> ONIA <br /> PANEL F OW CO I Y <br /> LFs lac a2c <br /> _ nD�K D x _ a CONSTRUCTION NOTES <br /> G1 1 DEMO EXISTING 30A RECEPTACLE, DISCONNECT SWITCH AND <br /> m z 4V33 1TNH15/ abc,3abc o CONDUCTORS BACK TO SOURCE PANEL. <br /> A� cz� 3/4" - 6#1011#10G 3abc <br /> o9x9£ a n� n m� �� O O INSTALL NEW 60A, 48OV, DISCONNECT SWITCH. <br /> N530 0 J � is BLO E <br /> n II ETO 6 x x x x CONNECT MATERIAL LIFT CONTROL PANEL TO EXISTING <br /> a � x x DISCONNECT PER MANUFACTURER'S INSTRUCTIONS. <br /> x O Q ® INSTALL NEW 3#6, 1#10G IN EXISTING CONDUIT. <br /> 13G11 <br /> m VyV x x x xx Ll 5. INSTALL (1) GE 'SELA' 60A BREAKER WITH 40A PLUG: <br /> oW AES-SEL60/40 IN PANEL 4V33-3GJ14.5-D/7ABC. <br /> cn J CONTACT ACCESS ELECTRIC DREW HADLEY: <br /> N W 206-293-1603 FOR PARTS. <br /> ° ° a Q w G K 6. TEMPORARY RELOCATE DISCONNECT AND CONDUITS TO <br /> x m w m —FEE FROM 30A, 480V DI NECT ALLOW INSTALLATION OF MATERIAL LIFT. COORDINATE EXACT <br /> H ON US DUCT 433 <br /> x uE 0- LOCATION OF DISCONNECT WITH MATERIAL LIFT PANEL <br /> X EA TUNNELAT COWMI 1-/14 1abc PRIOR TO INSTILLATION. <br /> mBENCH BENCH N BENCH <br /> 30"X72" <br /> - Y I 11 13 15 1 <br /> BENCH <br /> 1 00 00 O O O 09XOf-530 09%0£N530 09%O£ Lj 6��1 <br /> DINS GINS GINS GINS N530 v 11 1C2� 14 16 <br /> 9LX9£ H T <br /> I I I I fdl I I 0'6 E O <br /> 09x91 e>xa£ 4V33-3GJ14.5-D/7Gbc _ 1E110 1Ein 1En2 F <br /> lei 09x9£ 94x0£ leV1Dd DBL all Of <br /> 3/4"C - 3#6, 1#10G ¢ O <br /> SHEET 1A17 w <br /> or <br /> MATCH LINE -PoFOR CONTINUATION SEE SHEET 1A20 1 2 3 1E113 1Ena 1E11s <br /> 30A — — — — H —Gf 480Y/277 <br /> P <br /> 1 8N� 1E116 1E117 ' 1E118 <br /> I_O1E719 1E120 1E721 O <br /> 8' 4' 0 4' 8' 16' KEY PLAN BLDG. 40-33,� <br /> PARTIAL FIRST FLOOR 480V POWER PLAN N <br /> SCALE: 1/8" - 1'-0" SCALE: 1/8"=1'-O' <br /> SYM REVISION BY APPROVED DATE SYM RENSION BY APPROVED DATE DRAWN GATE SUBTITLE PARTIAL FIRST FLOOR 480V POWER PLAN CURRENT REVISION <br /> SYMBOL 1 ^ DATE 01.20.23 <br /> ACCEPTABILITY DRAWN HAH AT 25 07 \V/ <br /> L RELOCATE BAND SAW W4011927 SJO KER MNH 12.11.15 F HORIZONTAL STAB JOINT TO ELEV JOIN 56709200 HONARKHAH DH 05/04/07 THIS DESIGN AND/OR <br /> / SPECIFICATION IS APPROVED DH CHECKED 04/25/07 <br /> SHEET <br /> M POWER TO MATERIAL LIFT C248495 JC MDK 01.20.23 G PROCURE AND PROVIDE SEALANT FREEZERS J#576809-01 H.WEST KER/WRL 6/12/07 ® APPROVED BY DEPT. DATE HONARKHAH 04/25/07 TITLE N <br /> - H BATTERY CHARGER RELOCATION W1845386 BDH TT/RR 05.23.13 BOE, CHECKED 1 E 1 1 7 \ <br /> D ADD PWR/RELOCATE ENVIRONMENTAL BOOTH H48664 DOC DOC 05.23.98 J PANEL RENAME W1916045 MDK KR/BAO 04.15.14 APPROVED BUILDING 40-33 JOB No. coM40-033-1E117 <br /> E EMPENNAGE RELOCATE&J&I TRIM 56709200 HONARKHAH DH 04/25/07 K VFD UPGRADE FOR SF-1 AND SF-2 ON AHUs 14260512 MDK/SJO TT/BAO 10.01.14 APPROVED ELECTRICAL MASTER COL. GF-H/13-15 EVERETT, WAI <br /> DIG 10. 40-033-1E117 <br />