My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
6023 W BEECH ST 2023-07-14
>
Address Records
>
W BEECH ST
>
6023
>
6023 W BEECH ST 2023-07-14
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/14/2023 11:00:46 AM
Creation date
7/14/2023 10:56:34 AM
Metadata
Fields
Template:
Address Document
Street Name
W BEECH ST
Street Number
6023
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to(a) <br /> to tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-4613-900. If plan review <br /> is required, select the box next to(b)and(c)to acknowledge that plan review is required and the electrical plans have been <br /> provided with this permit application. <br /> *If item(a)411, iii,or v)is selected,the work must also comply with section(a)-(vii).See arrow flow chart below. <br /> (3) Electrical plan review. <br /> ✓❑ (a)Electrical plan review is not required for: <br /> ❑ (i)Low voltage systems; <br /> ❑ (ii)Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder. <br /> 13 system <br /> Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution <br /> system does not include: <br /> (A)Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2; or <br /> (C)A required fire pump system. <br /> (v)Modifications to existing electrical installations where all of the following conditions are met: <br /> (A)Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B)Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC <br /> 517.2; and <br /> (D)Service or feeder load calculations are increased by 5%or less. <br /> (vi)Electric power production source(s)such as solar photovoltaic,fuel cell,or wind electric system(s)with a total <br /> 0 rating of 9600 watts or less. <br /> ❑ (vii) For installations In(a)(ii),(iii),and(v)of this subsection to be considered,the following must be <br /> available to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope; <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed;and <br /> (D) Provide information showing that the service and feeder(s)supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcun-ent <br /> protection for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> ❑ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> (b)Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br /> occupancies defined in this chapter. <br /> ❑ (c) If a review is required,the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 900-1 <br /> Health or Personal Care Facilities Table900-2 <br /> Heald or Personal Care Facility Plan ReviEt•j <br /> Educational and Institutional Facilities. Places of Assembly.or Other Facilities <br /> Type Requires Educational Institutional.or Plan Review <br /> - Other Facility Types Regoired <br /> _, Votes to Tables 900-1 and 900-2. <br />
The URL can be used to link to this page
Your browser does not support the video tag.