Laserfiche WebLink
A B I C D E I F G H <br /> COMBINER BOX PANEL SIZE CALCS MAX AL;OPERATING <br /> NUMBER OF NUMBER OF NOMINAL OUTPUT COMBINED CURRENT FOR HM-1200.600.300 CONDUCTOR SCHEDULE <br /> TOTAL 125% TOTAL BREAKER SIZE INVERTER NUMBERR OF OMINAL OUTPUTCOMBINE <br /> CIRCUIT# MODULES MICROINVERTERS CURRENT TOTAL TOTAL <br /> CIRCUIT 1(1 Of 2) 1 1 X 1.23A = 1.23A = 1.54A TYPE INVERTERS CURRENT TOTAL CONDUCTORS GROUND <br /> CIRCUIT 1(2 of 2) 8 4 X 2.46A = 9.84A x 1.25 = 12.30A - 13.84A = 15A HM-1200 4 X 5.0A - 20.00A <br /> HM-600 4 X 2.46A = 9.84A - 31.07A TAG ID WIRES IN MINIMUM TYPE,MATERIAL MINIMUM TYPE,MATERIAL <br /> HM-300 1 X 1.23A - 1.23A CONDUIT WIRE SIZE WIRE SIZE <br /> CIRCUIT 2 8 2 X 5.OA = 10 ODA x 1.25 = 12.50A = N/A - <br /> A' 9 #12 AWG PV CABLE,CU #6 AWG BARE,CU <br /> CIRCUIT 8 2 X 5.OA = 10.00A x 1.25 = 12.50A = N/A 15A B 7 #12AWG THWN-2,CU #8AWG THWN-2,CU <br /> C3 #8AWG THWN-2,CU #8AWG THWN-2,CU <br /> D^ 4 #8AWG THWN-2,CU #8AW13 THWN-2,CU <br /> LOAD CALCS-TOTAL AMPS AVAILABLE BREAKER SIZE CALCS TAG A CABLE WILL BE RUN THROUGH ATTIC WHERE POSSIBLE *'TAG D ONLY IF APPLICABLE' <br /> BUS RATING 120% TOTAL MAIN BREAKER MAX BREAKER SIZE MAX AC OPERATING CURRENT 125% TOTAL BREAKER SIZE <br /> 200A X 1.2 = 240 200A = 40A I31.07A Ix 1 1.25 1 x I 38.84A = 40A <br /> NOTES: <br /> 1. 200A UTILITY METER GLOBE ONLY.(EXISTING) <br /> 2. 200A LOAD CENTER.(EXISTING) <br /> 1 ZNSHINE ZXM6-NH120-360M MODULE 8 ZNSHINE ZXM6-NH120-360M MODULES 3. 60A RATED NON-FUSED LOCKABLE AC DISCONNECT. <br /> WITH HOYMILES HM-300 MICRO INVERTER WITH HOYMILES HM-600 MICRO INVERTERS (NEW) <br /> (1 OF 2) (2 OF 2) <br /> 4. 125A RATED COMBINER PANEL.(NEW) <br /> N ---------- ---------— ALL CONDUIT SIZES ARE MINIMUM SIZES Nv <br /> ALL WIRE SIZES ARE FOR COPPER WIRE <br /> (11 (81 (21 (11 <br /> I <br /> I <br /> I <br /> I <br /> I <br /> I <br /> ti ti ti I <br /> I <br /> I <br /> I UTILITY <br /> I <br /> M 8 ZNSHINE ZXM6-NH120-360M MODULES I SERVICE w <br /> WITH HOYMILES HM-1200 MICRO INVERTERS 120 <br /> I SINGLEE PHASE <br /> II <br /> II <br /> (81 . . . (4) (3) (21 (1 II 1 <br /> II <br /> II A A <br /> I\V/I <br /> II <br /> II <br /> II (N)240V/60A PV <br /> II <br /> II 125A LOAD CENTER, <br /> ti II A NEMA 3R RATED 2 g (N)UTILITY 200A RATED <br /> 200A MAIN SERVICE <br /> II AC DISCONNECT <br /> MAIN <br /> II 240V/60A NEMA 3R DISCONNECTPANEL <br /> II NON-FUSIBLE, <br /> 8 ZNSHINE ZXM6-NH120-360M MODULES II VISIBLE-LOCKABLE (E)LOADS <br /> WITH HOYMILES HM-1200 MICRO INVERTERS15AII LABELED <br /> II <br /> ---------- ----- ----- ----- ----SII <br /> III 15A (N)PV OCPD <br /> (8) • • • (41 (31 (2) (11 III 15A 2P-40A <br /> ---� ✓ ✓ ---� .� III <br /> III � <br /> III <br /> L =________— = r-- — I <br /> • • . —, <br /> I I <br /> I I <br /> — NEMA3R RATED 40A LOAD-SIDE FACILITY GROUND <br /> LO JUNCTION BOX:SHALL SOLAR OCPD GROUND ROD <br /> COMPLY W/NEC 110.3 (Opposite end of the main disconnect <br /> &314.6 4 on the busbar-NEC 705.12(B)(3) <br /> SLIM DOWN BREAKERS TO <br /> ALLOW FOR SOLAR <br /> BREAKER CONNECTION <br /> DRAWN BY: DRAWING SCALE: <br /> CONFIDENTIAL-THE INFORMATION CONTAINED CM NOT TO SCALE <br /> IN THIS PACKET AND SUBSEQUENT CUTSHEETS DESIGN <br /> SO <br /> SHALL NOT BE USED FOR THE BENEFIT OF SOLGEN POWER Jose Nunez De Caceres EstradaDATE: <br /> LG r.-' N ANYONE OUTSIDE SOLGEN POWER. NEITHER 5715 BEDFORD ST, 22/03/2023 <br /> SHALL IT BE DISCLOSED TO OTHERS OUTSIDE PASCO, WA 99301 1 <br /> P O W E R THE RECIPIENT'S ORGANIZATION, EXCEPT IN 6406 Highland Drive, Everett, WA 98203 PAGE# <br /> CONNECTION WITH THE SALE AND USE OF THE P: 509-931-1663 <br /> RESPECTIVE EQUIPMENT, WITHOUT WRITTEN PV <br /> CONSENT FROM SOLGEN POWER. <br />