SITE PLAN NOTES: <br /> 1. THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE <br /> AO <br /> ENGINEER AT THE TIME OF THIS DESIGN.THE CONTRACTOR SHALL VISIT THE SITE <br /> PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO <br /> THE SCOPE OF WORK FOR THIS PROJECT. <br /> 2 ICE BRIDGE,CABLE LADDER,COAX PORT,AND COAX CABLE ARE SHOWN FOR AMERICAN TOWER <br /> REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL ATC TOWER SERVICES,LLC <br /> PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. 3500 REGENCY PARKWAY <br /> BEFORE UTILIZING EXISTING CABLE SUPPORTS,COAX PORTS,INSTALLING NEW <br /> 0 <br /> PORTS OR ANY OTHER EQUIPMENT,CONTRACTOR SHALL VERIFY ALL ASPECTS OF SUITE 1 27 <br /> THE COMPONENTS MEET THE ATC SPECIFICATIONS. CNE:(919) -8 <br /> PHONE: 468-0112 , <br /> 3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE ATC COA:3408 <br /> CONSTRUCTION MANAGER AND LOCAL UTILITY COMPANY FOR THE INSTALLATION " <br /> OF CONDUITS,CONDUCTORS,BREAKERS,DISCONNECTS,OR ANY OTHER THESE DRAWINGS AND/OR THE ACCOMPANYING <br /> EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL4. _, ARE THE , <br /> SPECIFICATION <br /> EXCLUSIVE OPERTYOFAMERCANTOOWERE THEIR USE AND <br /> BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND - PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL SITE ;, <br /> ----_ • FOR WHICH THEY ARE PREPARED.ANY USE OR DISCLOSURE G. <br /> NATIONAL CODES,ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. ,ems` l OTHER THAN THAT WHICH RELATES TO AMERICAN TOWER OR <br /> j`r ) THE SPECIFIED CARRIER IS STRICTLY PROHIBITED TITLE TO 0 <br /> 4. CONTRACTOR SHALL INSURE THAT ALL WORKING SPACE REQUIREMENTS ARE MET y_- -= THESE DOCUMENTS SHALL REMAIN THE PROPERTY OF <br /> PER APPLICABLE CODES AND MANUFACTURER SPECIFICATIONS. -- AMERICAN TOWER WHETHER OR NOT THE PROJECT IS <br /> _ EXECUTED NEITHER THE ARCHITECT NOR THE ENGINEER WILL <br /> BE PROVIDING ON-SITE CONSTRUCTION REVIEW OF THIS <br /> 5. ABOVE GROUND CONDUITS NEED TO BE SUPPORTED/FASTENED PER NEC 344,NEC PROJECT CONTRACTOR(s)MUST VERIFY ALL DIMENSIONS AND <br /> 352,AND PER ATC CONSTRUCTION SPECIFICATIONS. ADVISE AMERICANTOWER OF ANY DISCREPANCIES ANY PRIOR <br /> „ ISSUANCE OF THISIS DRAWING IS SUPERSEDED BY THE LATEST <br /> VERSION ON FILE WITH AMERICAN TOWER. <br /> 6. THE FOLLOWING SIGNS SHALL BE INSTALLED AT TENANT SERVICE MAIN �� • <br /> DISCONNECT PER NEC 702.7. (-"-GRAVEL REV DESCRIPTION BY DATE <br /> SURFACE 22'-0'"X 25"-6" <br /> 6.1. "CAUTION:TWO SOURCES OF SUPPLY STANDBY GENERATOR LOCATED SHELTER 0 FOR CONSTRUCTION MF 12/14/21 <br /> OUTDOORS" <br /> 6.2. "WARNING:SHOCK HAZARD EXISTS IF GROUNDING ELECTRODE CONDUCTOR -. <br /> OR BONDING JUMPER CONNECTION IN THIS EQUIPMENT IS REMOVED WHILE <br /> ALTERNATE SOURCE IS ENERGIZED" } <br /> RODENT CONTROL AROUND GENERATOR ENVELOPE: H-FRAME <br /> 1. INSTALL ALL PROVIDED SEALS,PLUGS,COVERS,ETC.IN GENERATOR AND FUEL ATC SITE NUMBER: <br /> TANK ENVELOPE. SEAL ALL REMAINING OPENINGS(EXCEPT NORMAL VENTING) v -f 83067 <br /> WITH RODENT FOAM SEALANT. NO OPENING SHALL BE LARGER THAN 1/4 INCH ANY I� tK � 4.1 � <br /> DIMENSION. EXISTING ( ` D D MiTh <br /> LATTICE TOWER t� �` B ATC SITE NAME: <br /> 2. SEAL ALL CONDUITS INCLUDING CONDUITS ENTERING GENERATOR EQUIPMENT, <br /> BOXES,ATTACHMENTS,ETC.WITH RODENT FOAM SEALANT. • T-MOBILE �� n II SOUTH EVERETT <br /> 3. SEAL ALL CONDUIT ACCESS OPENINGS THROUGH CONCRETE PAD WITH 3 X 3' B <br /> CON. PAD W/ HH GEN. ON EXISTING <br /> CONCRETE. 7' X 7' __ <br /> �\` CON. PAD SITE ADDRESS: <br /> 4. SLOPE GRAVEL BASE AT CONCRETE PAD PERIMETER FROM ABOVE PAD BASE TO GROUND SPACE ,„, ( 1 17' X 19' <br /> 709 80ST SW <br /> EXISTING GRADE LEVEL TYPICAL ALL PERIMETER SIDES. CON. PAD EVERETT,WA 98203 <br /> EXISTING T-MOBILE PANEL M s PROPOSED GEN.PAD igh <br /> ` 3'-4" W/80KW DIESEL GEN. SEAL <br /> F. <br /> FOR BACKUP POWER IV <br /> EXISTING , 1_ __ J 7",, (SEE SITE PLAN NOTE 4) <br /> T-MOBILE METER IAti F'V`4N ,d <br /> AND SERVICE MAIN 4 2 g'q' �F WA H <br /> LEGEND DISCONNECT / !RC' UTILIZE EXISTING 17'X 19' G N� ' <br /> CONCRETE PAD BY SAW CUTTING kQ' • tr. vt,i1 <br /> ® GROUNDING TEST WELL PROPOSED <br /> o OR CORE DRILLING AREA FOR c3 <br /> TENANT SERVICE MAIN, C7 <br /> ATS AUTOMATIC TRANSFER SWITCH \ STUB UP TO MATCH DETAIL ON <br /> 240V,200A,2-POLE B V 6'0" C-501 <br /> B BOLLARD NEMA 3R CIRCUIT BREAKER, / 'I / i , ,' , <br /> CSC CELL SITE CABINET OR FUSED DISCONNECT, °' -' i a iy"� <br /> D DISCONNECT SERVICE ENTRANCE RATED <br /> E ELECTRICAL / 0, treGi <br /> F FIBER <br /> GEN GENERATOR ArikPROPOSED H-FRAME PROPOSED POWER AND ©0 s`SIONAL, <br /> G GENERATOR RECEPTACAL FOR BACKUP POWER COMMUNICATIONS CONDUITS <br /> HH.V HAND HOLE,VAULT ®(SEE SITE PLAN NOTE 4) PER ELECTRICAL ONE-LINE <br /> DIAGRAM <br /> IB ICE BRIDGE PROPOSED Authorized by "EOR" <br /> K KENTROX BOX PROPOSED <br /> GENERATOR <br /> LC LIGHTING CONTROL R-o0 MONITORING UNIT 42 Dec 17 coIil ct 1 <br /> M METER E-STOP <br /> PB PULL BOX <br /> PP POWER POLE <br /> T TELCO <br /> TRN TRANSFORMER -- <br /> DRAWN BY: MF <br /> - CHAINLINK FENCE <br /> DATE DRAWN: 12/14/21 <br /> ATC JOB NO: 13739826_M4 <br /> 0 DETAILED SITE PLAN <br /> SITE PLAN <br /> APPROXIMATE TRENCH DISTANCES ° 10 20 e <br /> 20' POWER CONDUIT TRENCH SHEET NUMBER REVISION. <br /> SCALE:1"=5'(22X34) C-1 0 1 0 <br /> i. <br />