My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1313 HEWITT AVE 2023-11-01
>
Address Records
>
HEWITT AVE
>
1313
>
1313 HEWITT AVE 2023-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 9:20:13 AM
Creation date
7/25/2023 6:27:58 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1313
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SCHEDULE AND TIMER SETTING <br />Timer <br />ON/OFF timer <br />Turns ON and OFF daily at a set time. <br />Time can be set in 5-minute increments. <br />It is also possible to set the ON time only or the OFF time only. <br />Auto -OFF timer <br />Turns off the unit after a certain period of operation. <br />Operation time can beset to a value from 30 to 240 minutes in 10-minute increments. <br />Weekly timer <br />Weekly ON/OFF times and set temperatures can be set. <br />Time can beset in 5-minute increments. Up to 8 schedule patterns can beset per day of <br />the week. <br />Not valid when the ON/OFF timer is set. <br />RESTRICTION SETTINGS <br />Allows/disallows local operation <br />The following operation can be prohibited by applying certain settings on the centralized <br />controller: ON/OFF, operation mode, set temperature, filter sign reset, air direction, fan <br />speed and timer. <br />While an operation is prohibited, the operation icon lights up (only on the Main display in the <br />"Full" mode). <br />Operation lock <br />- The following operations can be prohibited: Sensing Location, ON/OFF, Mode, Set temp., <br />Menu, Fan, Louver, Vane, or Hold <br />Temperature range restriction <br />- The room temperature range for each operation mode can be restricted. <br />Auto return <br />The units operate at the preset temperature after a designated period. <br />Time can beset to a value from 30 to 120 minutes in 10-minute increments. <br />Not valid when the temperature setting range is restricted. <br />Password <br />- Administrator password (required for schedule setting etc.) and Maintenance password <br />(required for test run and function setting etc.) can be set. <br />SYSTEM EXAMPLE <br />*When a PAR-40MAAU is connected to a group, no other MA remote <br />controllers can be connected to the same group. <br />MISCELLANEOUS ITEMS <br />Language Selection <br />- Select the display language from the following 3 languages. <br />English, French, Spanish <br />Brightness Contrast <br />- The brightness of the LCD can be adjusted. The contrast of the LCD can be adjusted. <br />Manual Vane Angle *1 <br />- Fixes the vane position for each air outlet. <br />Service *1 <br />- Contains Test run, Function setting, Request code, and Error history. <br />3D i-see Sensor* <br />- Settings for 3D i-see Sensor® can be made. <br />ENERGY SAVING OPTION <br />No occupancy energy save <br />- Requires 3D i-see Sensor® on applicable indoor units <br />Room Occupancy energy save <br />- Requires 3D i-see Sensor® on applicable indoor units <br />• No occupancy Auto -OFF <br />- Requires 3D i-see Sensore on applicable indoor units <br />Setback Mode <br />*1 This function is active only for the units that support the function. <br />*2 The clock is accurate within 45 seconds per month (at the temperature of 77*F [250C]). <br />The clock is backed up for 3 days. <br />Non -polarized <br />2-wire <br />®Deluxe MA <br />remote <br />® o controller <br />Non -polarized <br />2-wire <br />Deluxe MA <br />remote <br />®b controller <br />Specifications are subject to change without notice. © 2021 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. <br />
The URL can be used to link to this page
Your browser does not support the video tag.