Laserfiche WebLink
NOTE <br />EQUIPMENT CABINET OMITTED FOR CLARITY <br />PROPOSED CPS UNIT PROPOSED CPS UNITS <br />\ <br />I <br />I <br />#2 AWG GROUND li <br />CONDUCTOR TO GROUND <br />PROPOSED CPS UNIT <br />MOUNT OR APPROVED <br />RESERVED SPACE FIBER KID, EQUIVALENT <br />I IF REQUIRED <br />F------------- <br />n <br />BPROPOSED <br />200AMP <br />METER SOCKET <br />I PROPOSED DISH <br />i WIRELESS, L.L.C. <br />POWER PROTECTIVE <br />11 CABINET <br />II <br />i ° <br />I PROPOSED PIPE COLUMN <br />1 <br />l <br />a <br />i <br />P <br />I <br />I <br />P <br />S <br />NOTE <br />CABLE GROUNDING NOT REQUIRED WHEN <br />ANTENNA IS LESS THAN 10' FROM CABINET <br />PROPOSED POST <br />PROPOSED PIPE CLAMPS <br />O <br />1/2" COAX CABLE 8" u 1 <br />MINIMUM BENDING RADIUS ` <br />PER CABLE MANUFACTURER'S ` <br />SPECIFICATIONS `rTO GROUND <br />TYPICAL GPS UNIT GROUNDING NO SCALE 2 <br />1 <br />it PROPOSED <br />PROPOSED TELCO FIBER <br />I DISH WIRELESS, i <br />ENCLOSURE (BEHIND) <br />d L.L.C. SAFETY <br />SWITCH. <br />� INSTALL IF <br />III <br />PROPOSED EQUIPMENT PAD <br />�i <br />III REQUIRED BY III <br />l i LOCAL UTILITY <br />COMPANYI <br />PROPOSED #2 AWG TIE INTO <br />it----- <br />I` ILI------ - Im <br />-�-�I <br />f <br />GROUND RING (TYP) <br />#2 TINNED SOLID IN 1/2" MIN. LIQUID <br />_ <br />-� o o o <br />TIGHT CONDUIT FROM 24" BELOW GRADE <br />o0 O O <br />TO WITHIN 3" TO 6" OF CAD -WELD <br />■ O O O O O ■ <br />TERMINATION POINT. EXPOSED END OF <br />THE LIQUID TIGHT CONDUIT MUST BE <br />SEALED WITH SILICONE CAULK. (TYP) <br />II II i <br />/ <br />PROPOSED <br />BOND EQUIPMENT III a <br />GROUND BAR TO I\ <br />PROPOSED GROUND RING <br />\ <br />GROUND BUS BAR <br />�I <br />a <br />Ii a ELECTRODE <br />LECTR <br />ELECTRODEDE 1 \� r <br />a / <br />I <br />SYSTEM (TYP) 4 j <br />�; <br />BASE CONNECTION <br />/ PROPOSED <br />SERVICE ENTRANCE <br />GROUNDING <br />` <br />_ <br />/�" GROUND RING <br />ELECTRODE <br /># 2 GROUND <br />CONDUCTOR (GEC) <br />NO SCALE <br />OUTDOOR CABINET GROUNDING <br />No SCALE <br />3 <br />12" DIA x 24" DEEP <br />#2 TINNED SOLID IN 1/2" MIN. LIQUID <br />xQ <br />ORPSOILON SLEEVEPVC <br />ITH CAP <br />TIGHT CONDUIT FROM 24" BELOW GRADE <br />PIPE <br />x <br />OR EQUIVALENT <br />TO WITHIN 3" TO 6" OF CAD -WELD All <br />1'-0" <br />TERMINATION POINT. EXPOSED END OF <br />N <br />zI <br />THE LIQUID TIGHT CONDUIT MUST BE i <br />SEALED WITH SILICONE CAULK. / <br />FINISHED GRADE <br />INCLUDE WARNING TAPE WITH <br />_ <br />BACKFILL PER SPECIFICATIONS <br />GRADE <br />o00 O A����� <br />X, �X XEXOTHERMIC CONNECTION <br />o w w <br />j�/' <br />m Z N <br />i <br />CRUSHED O <br />1 <br />�� ST WELL TO <br />TEST <br />p w <br />WITHIN 2" OF TOP OF <br />GROUNDING LOOP CONDUCTOR <br />_ w <br />M E <br />GROUND RING, #2 AWG <br />SOLID BARE TINNED <br />CADWEL (TYP) I <br />GROUND RING <br />COPPER CONDUCTOR <br />>L <br />#2 AWG SOLID TINNED <br />TIE INTO EXISTING <br />COPPER CONDUCTOR <br />GROUND RING a <br />EXTERIOR GROUND RING <br />GROUND ROD, 1/2" MIN. x 8'-0" <br />LONG COPPER CLAD STEEL <br />(ERICO #625880) <br />TRANSITIONING GROUND DETAIL <br />NO SCALE <br />4 <br />TYPICAL TEST GROUND ROD <br />WITH INSPECTION SLEEVE <br />No SCALE <br />5 <br />TYPICAL GROUND RING TRENCH <br />NO SCALE <br />6 <br />d..*.sh <br />wireless- <br />5701 SOUTH SANTA FIE DRIVE <br />LITTLETON, CO 80120 <br />i <br />Al <br />TOWER ENGI EE N PROFESSIONALS <br />326 TRY ALEIGH, INC <br />27603 CE: 9 ) 661-6351 <br />M A <br />� <br />SH <br />^J <br />50257 <br />SIGNAL <br />`Matto 8,2022 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE <br />DIRECTION OF A LICENSED PROFESSIONAL <br />ENGINEER, TO ALTER THIS DOCUMENT. <br />DRAWN BY: <br />CHECKED BY: <br />APPROVED BY: <br />CDK I <br />CP <br />CP <br />REDS REV #: TBD <br />CONSTRUCTION <br />DOCUMENTS <br />SUBMITTALS <br />REV <br />DATE <br />DESCRIPTION <br />.1 <br />08-05-21 <br />PRELIMINARY <br />B <br />12-21-21 <br />PRELIMINARY <br />C <br />01-18-22 <br />PRELIMINARY <br />0 <br />03-08-22 <br />CONSTRUCTION <br />A&E PROJECT NUMBER <br />147003 <br />DISH WIRELESS, L.L.C. <br />PROJECT INFORMATION <br />SESEA00361C <br />9610 19TH AVENUE SE <br />EVERETT, WA 98208 <br />SHEET TITLE <br />GROUNDING DETAILS <br />SHEET NUMBER <br />G -2 <br />