My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9606 19TH AVE SE DISH WIRELESS 2023-08-01
>
Address Records
>
19TH AVE SE
>
9606
>
DISH WIRELESS
>
9606 19TH AVE SE DISH WIRELESS 2023-08-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2023 2:56:21 PM
Creation date
7/27/2023 7:50:43 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9606
Tenant Name
DISH WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES DC POWER WIRING SHALL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND —48V CONDUCTORS. <br /> RED MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SHALL IDENTIFY —48V. <br /> 1. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED UNDERGROUND UTILITY CONDUIT ROUTE. • <br /> 2. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. <br /> 3. THE GROUND LEASE PROVIDES BROAD/BLANKET UTILITY RIGHTS. "PWR" AND "FBR" PATH DEPICTED ON A-1 AND E-1 ARE BASED ON BEST AVAILABLE INFORMATION INCLUDIKG 1 CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. ANY QUESTIONS ARISING <br /> BUT NOT LIMITED TO FIELD VERIFICATION, PRIOR PROJECT DOCUMENTATION AND OTHER REAL PROPERTY RIGHTS DOCUMENTS. WHEN INSTALLING THE UTILITIES PLEASE LOCATE DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY <br /> AND FOLLOW EXISTING PATH. IF EXISTING PATH IS NOT AN OPTION, PLEASE NOTIFY TOWER OWNER AS FURTHER COORDINATION MAY BE NEEDED. OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT <br /> d ...sh <br /> MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. Wireless ry <br /> 2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL <br /> STATE AND LOCAL CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS 5701 SOUTH SANTA FE DRIVE <br /> REQUIRED TO MEET NEC STANDARDS. <br /> LITTLETON, CO 80120 <br /> 3. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE <br /> COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. <br /> 4. CONDUIT ROUGH—IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. <br /> VERIFY WITH THE MECHANICAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. <br /> 5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. <br /> 6. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. <br /> 7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES. <br /> INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. <br /> 8. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES TOWER ING PROFESSIONALS <br /> INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. 326 D. RALEIGH, NC <br /> 27603 FI E: (919) 661-6351 <br /> 9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250. <br /> THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL <br /> DISCONNECT SWITCHES, AND EQUIPMENT CABINETS. A <br /> 10. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. <br /> 11. PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST—CONSTRUCTION EQUIPMENT. al S✓y�^, <br /> 12. CONTRACTOR SHALL BE RESPONSIBLE FOR AS—BUILT PANEL SCHEDULE AND SITE DRAWINGS. !!�� •, N <br /> APPROXIMATE LOCATION OF V h Z <br /> EXISTING GROUND—MOUNTED 13. ALL TRENCHES IN COMPOUND TO BE HAND DUG. <br /> TRANSFORMER <br /> REINFORCE PER SBA STANDARDS 14. CONTRACTOR TO VERIFY HANDHOLE AND/OR PULL BOXES REQUIREMENTS WITH SELECTED FIBER PROVIDER <br /> FOR CONDUITS TRAVELING ACROSS PRIOR TO CONSTRUCTION OF TRENCH. ^Y <br /> PROPOSED 2" UNDERGROUND FIBER VEHICLE ZONES TO AVOID DAMAGE150257GGQ <br /> CONDUIT(LENGTH: 75'-0"t) WITH <br /> 400—Ib MULE TAPE TO BE INSTALLEDCC V' <br /> BY <br /> COORDINATE ROUTING WITH UTEUNDERGROUNDACTOR PROPOSED 3" POWER <br /> UTILITY CONDUIT 10' O"±) FROM TNAL <br /> COMPANY. SEE NOTE 3. VERIFY PROPOSED 200A METER TO EXISTING <br /> AGAINST FINAL APPROVED TELCO GROUND—MOUNTED TRANSFORMER TO BE <br /> DESIGN PRIOR TO CONSTRUCTION. INSTALLED BY DISH WIRELESS, L.L.C. <br /> Marcfi 8,2022 <br /> CONTRACTOR TO COORDINATE ROUTING WITH <br /> V UTILITY COMPANY. IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE <br /> X X EBB <br /> FDR EBB FBR FBR FBR BR X X DIRECTION OFA LICENSED PROFESSIONAL <br /> ENGINEER,TO ALTER THIS DOCUMENT. <br /> m <br /> A DRAWN BY: CHECKED BY:APPROVED BY: <br /> PWR <br /> x x CDK CP CP <br /> RFDS REV #: TBD <br /> m <br /> CONSTRUCTION <br /> x 11 x DOCUMENTS <br /> SUBMITTALS <br /> REV DATE DESCRIPTION <br /> X x x X � x <br /> A 08-05-21 PRELIMINARY <br /> DISH WIRELESS, L.L.C. CONTRACTOR TO k B 12-21-21 PRELIMINARY <br /> STUB UP 2" CONDUIT FOR FIBER 5 FTC 01-18-22 PRELIMINARY <br /> ABOVE GRADE NEAR EXISTING FIBER X X X X X � 0 03-08-22 CONSTRUCTION <br /> HAND HOLE. VERIFY AGAINST FINAL <br /> APPROVED TELCO DESIGN PRIOR TO <br /> CONSTRUCTION. <br /> APPROXIMATE LOCATION OF <br /> EXISTING FIBER HAND HOLE A&E PROJECT NUMBER <br /> 147003 <br /> DISH WIRELESS, L.L.C. <br /> PROJECT INFORMATION <br /> SESEA00361C <br /> 9610 19TH AVENUE SE <br /> EVERETT, WA 98208 <br /> SHEET TITLE <br /> ELECTRICAL/FIBER ROUTE <br /> PLAN AND NOTES <br /> N SHEET NUMBER <br /> VERIFY C_1 <br /> 8' 4' 0 8' 1 E <br /> UTILITY ROUTE PLAN ELECTRICAL NOTES FNo scALE 2 G <br />