Laserfiche WebLink
4205 Ridgemont Drive(#1051582) /lr IRONRIDGE <br /> pitched roof 28357 INDUSTRIAL BLVD.,HAYWARD,CA 94545 <br /> Project Details <br /> Name 4205 Ridgemont Drive Date 10/19/2022 <br /> Location 4205 Ridgemont Drive, Everett, WA 98203 Total modules 25 <br /> Module Mission Solar Energy: MSE385SX5R(40mm) Total watts 9,625 <br /> Dimensions Dimensions: 75.08" x 41.1" x 1.57" (1907.Omm x 1044.Omm x 40.Omm) Attachments 50 <br /> ASCE 7-10 Rails per row 2 <br /> System Weight Load Assumptions <br /> Total system weight 1,509.5 lbs Wind exposure B <br /> Weight/attachment 30.2 lbs Wind speed 110 mph <br /> Racking weight 297.0 lbs Ground snow load 25 psf <br /> Distributed weight 2.8 psf Attachment spacing portrait 4.0' <br /> Roof Information <br /> Roof Material Family Shake Roof material Shake <br /> Building height 25 ft Roof attachment Classic Shake Mount <br /> Roof slope 18 ° Attachment hardware T Bolt <br /> Risk category II <br /> Span Details XR100 - Portrait Reaction Forces XR100 - Portrait <br /> Zone Down Uplift Lateral <br /> Zone Max span Max cantilever Obs) (lbs) (lbs) <br /> 1 7' 3" 2- 11" 1 264 100 71 <br /> 2 7' 3" 211111 2 264 210 71 <br /> 3 7' 3" 2- 11" 3 264 334 71 <br /> Last updated by Alana Nelson on 10/19/22 01:29 PM Page 1 of 7 <br />