t. <br /> EVERETT WAC 296-46B-900: ELECTRICAL PLAN.REVIEW <br /> MSI NIN�TON <br /> DIRECTIONS: Read the WAC section below to determine if plan review is required or not required. Then select the box next to(a) <br /> to tell City Staff if plan review is not requried and select the box next to the specific reason from WAC 296-4613-900. If plan review <br /> is required, select the box next to(b)and (c)to acknowledge that plan review is required and the electrical plans have been <br /> provided with this permit application. <br /> If item (a)-(ii, iii, or v) is selected,the work must also comply with section (a)-(vii).See arrow flow chart below. <br /> (3) Electrical plan review. <br /> ✓0 (a) Electrical plan review is not required for: <br /> ❑ (i) Low voltage systems; <br /> -i El (ii) Lighting specific projects that result in an electrical load reduction on each feeder involved in the project; <br /> ❑ (iii) Heating and cooling specific retrofit projects that result in an electrical load reduction on each existing feeder <br /> involved in the project, provided there is not a corresponding increase in the available fault current in any feeder, <br /> ❑ (iv) Stand-alone utility fed services that do not exceed 250 volts, 400 amperes where the project's distribution <br /> system does not include: <br /> (A) Emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (B)An essential electrical system defined in NEC 517.2; or <br /> (C)A required fire pump system. <br /> ❑✓ (v) Modifications to existing electrical installations where all of the following conditions are met: <br /> (A) Service or distribution equipment involved is rated not more than 400 amperes and does not exceed <br /> 250 volts or for lighting circuits not exceeding 277 volts to ground; <br /> (B) Does not involve emergency systems other than listed unit equipment per NEC 700.12(F); <br /> (C) Does not involve branch circuits or feeders of an essential electrical system as defined in NEC <br /> 517.2; and <br /> (D) Service or feeder load calculations are increased by 5%or less. <br /> ❑ (vi) Electric power production source(s) such as solar photovoltaic, fuel cell, or wind electric system(s)with a total <br /> rating of 9600 watts or less. <br /> ❑ (vii) For installations in (a)(ii), (iii), and (v) of this subsection to be considered,the following must be <br /> available to the electrical inspector before the work is initiated: <br /> (A)A clear and adequate description of the project's scope, <br /> (B)A load calculation(s); <br /> (C)What the load changes are, providing both before and after panel schedules as needed; and <br /> (D) Provide information showing that the service and feeder(s) supplying the panel(s)where the work is <br /> taking place has adequate capacity for any increased load and has code compliant overcurrent <br /> protection for that supply. <br /> NOTE: Electrical plan review is not required for"Medical, dental, and chiropractic clinic"of which is a clinic or <br /> ❑ physicians'office where patients are not regularly kept as bed patients for twenty-four hours or more, per section <br /> (1)(c)(xii). <br /> ❑ (b) Electrical plan review is required for all other new or altered electrical projects in educational, institutional, or health care <br /> occupancies defined in this chapter. <br /> (c) If a review is required, the electrical plan must be submitted for review and approval before the electrical work is begun. <br /> Table 900.1 Table 900.2 <br /> Health or Personal tare Facilities Educational and Institutional Facilities,Places of Assembly,or other Facilities <br /> Health or Personal Care Facility Plan Review <br /> Type Required Educational,Institutional,or Plan Review <br /> -oscaa: other Facility Types Required <br /> \U•s:nb cwe un t or Ic,g.te-T Yes _Cucat Cna Yes <br /> care..n.t n_ttut;cna; 1'es <br /> Bca'clna ncn`e "es <br /> Ass sted 1;,,ng faci;-t; Yes <br /> Or::ate a coho°srn hoscita yes Notes to Tables 900.1 and 900.2. <br /> Orvate osyci atr c host tal Yes .A city aUTncr,zeo tc dc e ectr,Cal.nspecticr< <br /> Vater,)t,roc,e Yes may reclu re o an ev evr on faci icy tyces not <br /> A.mbuaterysurge y`ac ir; Yes e:ie;:e0 u;tneciepa•trent. <br /> Rend gCrn1n,a;51e c Ink <br /> Res cent;al r-eatregt faci iv; 'v?s <br /> 2n^ancese Jce fact,(; "es <br /> o <br /> ka�lt e_o?rt'a �enakA,tatio- Yes <br /> PERMIT# `� Page 2-Plan Review <br /> Cense, <br />