Laserfiche WebLink
ERIGHT <br /> Design Wind Loads Ef� rn g i In <br /> e e m $ <br /> Solid Freestanding Walls and Solid Signs [CASE A ONLY] <br /> (E) Menuboard <br /> DESCRIPTION: Taco Bell Project No. 230102-161 <br /> Everett,WA <br /> BASIC WIND SPEED(MPH): 110 KZt: 1.00 <br /> EXPOSURE: C Kd: 0.85 <br /> No.OF SIGN SEGMENTS: 2 G: 0.85 <br /> LOC. B(ft) S(ft) h (ft) Af(ft) yBAR(ft) KZ qZ Cf F(K) M (K-FT) <br /> A 7.61 5.84 6.54 44.50 3.61 0.85 22.38 1.65 1.397 5.048 <br /> B 2.75 0.69 0.69 1.90 0.35 0.85 22.38 1.50 0.054 0.019 <br /> DEMAND LOADS FROM EXISTING MENUBOARD.TO BE TOTAL: 1.451 5.067 <br /> USED ON THE FOLLOWING SHEET FOR COMPARISON <br /> yBAR(FT) : 3.493 <br /> LRFD F„(k): 1.4508 LRFD M„(k-ft): 5.07 <br /> ASD F„(k): 0.8705 ASD M„(k-ft): 3.040342 <br /> TACO BELL SC1230102-161 C1 <br /> PROJECT: No: SHEET: <br />