Laserfiche WebLink
1 . 11 RIGHT <br /> Hilti PROMS Engineering 3.0.77 ap. Im i n f e r s <br /> www.hilti.com <br /> Company: Page: 13 <br /> Address: Specifier: <br /> Phone I Fax: E-Mail: <br /> Design: Date: 5/9/2022 <br /> Fastening point: <br /> V[lb] (ORn[lb] Utilization[%] Status <br /> Anchor 4 220 58,725 1 OK <br /> 2.5 Concrete <br /> Decisive load combination: 1 -Equation(16-4a) <br /> 2.5.1 Compression in concrete under the anchor plate <br /> 384 psi <br /> • <br /> 0 psi <br /> 2.5.2 Concrete block compressive strength resistance check,AISC 360-16 Section J8 <br /> Equations <br /> Fp - (D fp,max <br /> fp,max = 0.85 fc�( At A2 )<_1.7 fc; At A2 )!5 2 <br /> N <br /> 6 At <br /> Utilization = 6 <br /> Fp <br /> Variables <br /> N [lb] fc,[psi] At [in'] A2[in'] <br /> 7,474 3,000 0.65 42.33 447.41 <br /> Input data and results must be checked for conformity with the existing conditions and for plausibility! <br /> PROFIS Engineering(c)2003-2022 Hilti AG,FL-9494 Schaan Hilti is a registered Trademark of Hilti AG,Schaan <br /> TACO BELL SC1230102-161 C14 <br /> PROJECT: No: SHEET: <br />