Laserfiche WebLink
SPECIFICATIONS <br />Sensitivity: <br />• UL Applications: 0.5% to 4.0% per foot obscuration. <br />• ULC Applications: 0.5% to 3.5% per foot obscuration <br />Size: 2.0" (5.3 cm) high; base determines diameter <br />— B300-6: 6.1" (15.6 cm) diameter <br />— B501: 4" (10.2 cm) diameter <br />For a complete list of detector bases see DN-60981 <br />Shipping weight: 3.4 oz. (95 g) <br />Operating temperature range: <br />• FSP-951: 32°F to 122°F (0°C to 50oC) <br />• FSP-951T Series: 32°F to IOOoF(0°C to 38°C) <br />• FSP-951 R Series installed in a DNR/DNRW, -4°F to 158°F (-20°C <br />to 70°C) <br />UL/ULC Listed Velocity Range: 0-4000 ft/min. (1219.2 m/min.), <br />suitable for installation in ducts <br />Relative humidity: 10% — 93% non -condensing <br />Thermal ratings: fixed -temperature set point 135°F (57°C), rate -of - <br />rise detection 15°F (8.3°C) per minute, high temperature heat 190°F <br />(88-C) <br />ELECTRICAL SPECIFICATIONS <br />Voltage range: 15 - 32 volts DC peak <br />Standby current (max. avg.): 200pA @ 24 VDC (one communica- <br />tion every 5 seconds with LED enabled) <br />Max current: 4.5 mA @ 24 VDC ("ON") <br />DETECTOR SPACING AND APPLICATIONS <br />NOTIFIER recommends spacing detectors in compliance with NFPA <br />72. In low airflow applications with smooth ceiling, space detectors <br />30 feet (9.1 m). For specific information regarding detector spacing, <br />placement, and special applications refer to NFPA 72. A System <br />Smoke Detector Application Guide, document A05-1003, is avail- <br />able at www.systemsensor.com. <br />NOTIFIER <br />12 Clintonville Road <br />Northford, CT 06472 <br />203.484.7161 <br />www.notifier.com <br />I® <br />ENRINEERINR IIIMANUFACTURINL <br />QUALITY SYSTEMS <br />Listings and Approvals <br />Listings and approvals below apply to the FSP-951 Series detectors. <br />In some cases, certain modules may not be listed by certain <br />approval agencies, or listing may be in process. Consult factory for <br />latest listing status. <br />• UL/ULC Listing: S1115 <br />• FM Approved <br />• CSFM:7272-0028:0503 <br />This document is not intended to be used for installation purposes. <br />We try to keep our product information up-to-date and accurate. <br />We cannot cover all specific applications or anticipate all requirements. <br />All specifications are subject to change without notice. <br />FlashScan® NOTIFIERO, and System Sensor® are registered trademarks <br />of Honeywell International, Inc. <br />©2019 by Honeywell International Inc. All rights reserved. Unauthorized <br />use of this document is strictly prohibited. <br />Country of Origin: Mexico <br />�J NOTIFIER <br />by Honeywell <br />