My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2828 COLBY AVE KIMLEY HORN 2025-04-16
>
Address Records
>
COLBY AVE
>
2828
>
KIMLEY HORN
>
2828 COLBY AVE KIMLEY HORN 2025-04-16
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2025 1:34:52 PM
Creation date
7/27/2023 10:44:27 AM
Metadata
Fields
Template:
Address Document
Street Name
COLBY AVE
Street Number
2828
Tenant Name
KIMLEY HORN
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
122
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN-60938:B <br />Indoor Selectable -Output <br />Strobes and Horn Strobes for <br />Ceiling Applications <br />General <br />System Sensor L-Series audible visible notification products <br />are rich with features guaranteed to cut installation times and <br />maximize profits with lower current draw and modern aesthet- <br />ics. <br />The System Sensor L-Series offers the most versatile <br />and easy -to -use line of horns, strobes, and horn strobes in the <br />industry with lower current draws and modern aesthetics. With <br />white and red plastic housings, wall and ceiling mounting <br />options, System Sensor L-Series can meet virtually any appli- <br />cation requirement. <br />The entire L-Series product line of ceiling -mount strobes and <br />horn strobes include a variety of features that increase their <br />application versatility while simplifying installation. All devices <br />feature a plug-in design with minimal intrusion into the back <br />box, making installations fast and foolproof while virtually elim- <br />inating costly and time-consuming ground faults. <br />To further simplify installation, the L-Series utilizes a universal <br />mounting plate so installers can mount them to a wide array of <br />back boxes. With an onboard shorting spring, installers can <br />test wiring continuity before the device is installed. <br />Installers can also easily adapt devices to a suit a wide range <br />of application requirements using field -selectable candela set- <br />tings, automatic selection of 12- or 24-volt operation, and a <br />rotary switch for horn tones with two volume selections. <br />Features <br />• Plug-in design with minimal intrusion into the back box <br />• Tamper -resistant construction <br />• Automatic selection of 12- or 24-volt operation <br />at 15 and 30 candela <br />• Field -selectable candela settings on ceiling units: <br />15, 30, 75, 95, 115, 150, and 177 <br />• Horn rated at 88+ dBA at 16 volts <br />• Rotary switch for horn tone and two volume selections <br />• Universal mounting plate for ceiling units <br />• Mounting plate shorting spring feature checks wiring conti- <br />nuity before device installation <br />• Electrically compatible with legacy SpectrAlert and <br />SpectrAlert Advance devices <br />• Compatible with MDL3 sync module <br />• Listed for ceiling mounting only <br />�J NOTI FI ER" <br />by Honeywell <br />SCRL <br />PC2WL <br />Architect/Engineer Specifications <br />GENERAL <br />L-Series ceiling -mount strobes and horn strobes shall mount <br />to a standard 4 x 4 x 11/z-inch back box, 4-inch octagon back <br />box, or double -gang back box. Two -wire products shall also <br />mount to a single -gang 2 x 4 x 17/8 inch back box. A universal <br />mounting plate shall be used for mounting ceiling and wall <br />products. The notification appliance circuit wiring shall termi- <br />nate at the universal mounting pate. Also, L-Series products, <br />when used with the Sync•CircuitTM Module accessory, shall be <br />powered from a non -coded notification appliance circuit output <br />and shall operate on a nominal 12 or 24 volts. When used with <br />the Sync -Circuit Module, 12-volt-rated notification appliance <br />circuit outputs shall operate between 8.5 and 17.5 volts; 24- <br />volt-rated notification appliance circuit outputs shall operate <br />between 16.5 and 33 volts. Indoor L-Series products shall <br />operate between 32 and 120 degrees Fahrenheit from a regu- <br />lated DC or full -wave rectified unfiltered power supply. Ceiling <br />strobes and horn strobes shall have field -selectable candela <br />settings including 15, 30, 75, 95, 115, 150, and 177. <br />STROBE <br />The strobe shall be a System Sensor L-Series Model <br />listed to UL 1971 and shall be approved for fire protective ser- <br />vice. The strobe shall be wired as a primary -signaling notifica- <br />tion appliance and comply with the Americans with Disabilities <br />Act requirements for visible signaling appliances, flashing at 1 <br />Hz over the strobe's entire operating voltage range. The strobe <br />light shall consist of a xenon flash tube and associated lens/ <br />reflector system. <br />HORN STROBE COMBINATION <br />The horn strobe shall be a System Sensor L-Series Model <br />listed to UL 1971 and UL 464 and shall be approved <br />for fire protective service. The horn strobe shall be wired as a <br />primary -signaling notification appliance and comply with the <br />Americans with Disabilities Act requirements for visible signal- <br />ing appliances, flashing at 1 Hz over the strobe's entire operat- <br />ing voltage range. The strobe light shall consist of a xenon <br />flash tube and associated lens/reflector system. The horn shall <br />have two audibility options and an option to switch between a <br />temporal three pattern and a non -temporal (continuous) pat- <br />tern. These options are set by a multiple position switch. The <br />horn on horn strobe models shall operate on a coded or non - <br />coded power supply. <br />DN-60938:B • 5/15/17 — Page 1 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.