• • <br /> t <br /> Drew Martin <br /> From: Drew Martin <br /> Sent: Friday, September 11, 2020 1:14 PM <br /> To: Aaron Dupont <br /> Subject: RE: City of Everett Permit Services: 8115 Xavier Way(C2007-003) - First Building Review <br /> Aaron, <br /> Unfortunately, I won't have time to wait for additional responses and perform the redlines. I need to keep the reviews <br /> moving for other departments. Please use the email that I sent yesterday as the review letter and provided updated <br /> documents. We will need two sets of revised drawings and supplemental calculations as needed to substantiate the <br /> remaining portions of the design. <br /> Drew Martin, P.E., S.E. <br /> inAssociate Engineer—Commercial Plans Examiner I Permit Services <br /> 425.257.8813 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> EVERETT Hours: M/W/Th/F: 7:30am-12:00pm & 1:00pm-3:00pm;Tu: 1:00pm-3:00pm <br /> everettwa.gov I Facebook I Twitter <br /> COVID-19 Update: Please reference our website& online resources for updates to our service during the <br /> COVID-19 pandemic. We are currently experiencing a higher volume of calls and emails and have limited staff <br /> available to respond. Your patience is appreciated as we respond in the order received. <br /> Note:Emails and attachments sent to and from the City of Everett are public records and may be subject to disclosure pursuant to the Public <br /> Records Act. <br /> From: Drew Martin <br /> Sent: Friday, September 11, 2020 10:57 AM <br /> To:Aaron Dupont<akd.archdesign@gmail.com> <br /> Subject: Re: City of Everett Permit Services: 8115 Xavier Way(C2007-003)- First Building Review <br /> Aaron, <br /> This response is not correct. Truss manufacturers provided stability bracing for the trusses, but they typically <br /> do not design out-of-plane bracing (i.e., wind,wall stability, etc.) for the exterior walls that are supporting the <br /> trusses. or clarity,the connection between the truss bottom chord and wall top plate is a hinge point in the <br /> wall, preventing adequate lateral resistance and stability for the wall. This must be addressed by the <br /> EOR. Note that this bracing must also support a portion of tributary areas from the bottom half of the truss <br /> area. <br /> ,J 0 rew Martin,P.E.,S.E. <br /> ssociate Engineer—Commercial Plans Examiner I Permit Services <br /> 25.257.8813 13200 Cedar Street, 2nd Floor, Everett,WA 98201 <br /> Hours: M/W/Th/F:7:30am-12:00pm &1:OOpm-3:OOpm;Tu: 1:OOpm-3:OOpm <br /> everettwa.gov I Facebook I Twitter <br /> 119 <br />