My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
8115 XAVIER WAY 2023-08-08
>
Address Records
>
XAVIER WAY
>
8115
>
8115 XAVIER WAY 2023-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2023 10:33:42 AM
Creation date
7/28/2023 1:28:12 PM
Metadata
Fields
Template:
Address Document
Street Name
XAVIER WAY
Street Number
8115
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
f • • <br /> Simple Heating System Size:Washington State <br /> This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Ener 1 C.. W a i C 1�`1 <br /> Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems shou'd b-w, •t.�•'-er •j ' <br /> loads. <br /> Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-do M ,r t035,s2ON, J <br /> some values will be calculated for you.If you do not see the selection you need in the drop-down options,please cal tie WSU Energy Extension 1 <br /> Program at(360)956-2042 for assistance. ,-J <br /> CITY OF EVERETT <br /> Project Information Contact Information Permit Services <br /> New Addition Garrett Johnson <br /> 8115 Xavier Way <br /> Everett,WA 98203 <br /> Heating System Type: ®All Other Systems 0 Heat Pump <br /> To see detailed instructions for each section,place your cursor on the word"Instructions". <br /> Design Temperature <br /> Instructions Design Temperature Difference(AT) 47 <br /> Everett JC AT=Indoor(70 degrees)-Outdoor Design Temp <br /> Area of Building <br /> Conditioned Floor Area <br /> Instructions Conditioned Floor Area(sq ft) 1,108 <br /> Average Ceiling Height Conditioned Volume <br /> Instructions Average Ceiling Height(ft) 8.0 8,864 <br /> Glazing and Doors U-Factor X Area = UA <br /> Instructions <br /> 0-0.28 . 0.280 103 28.84 <br /> Skylights U-Factor X Area = UA <br /> Instructions 0.50 --- <br /> Insulation <br /> Attic U-Factor X Area = UA <br /> Instructions R-49 0.026 1,108 28.81 <br /> Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA <br /> Instructions No selection <br /> 0 Select R-Value •iil <br /> Above Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions 0.056 764 42.78 <br /> Ill R-21 Intermediate • <br /> Floors U-Factor X Area UA <br /> Instructions 0.025 1,108 27.70 <br /> R-38 <br /> Below Grade Walls(see Figure 1) U-Factor X Area UA <br /> Instructions No selection --- <br /> 0 Select R-value •iiij <br /> Slab Below Grade(see Figure 1) F-Factor X Length UA <br /> Instructions ii No selection --- <br /> Select conditioning v <br /> Slab on Grade(see Figure 1) F-Factor X Length UA <br /> Instructions --- <br /> <„Select R-Value ..,::. No selection <br /> Location of Ducts <br /> Instructions Duct Leakage Coefficient <br /> Unconditioned Space • <br /> 1.10 <br /> Sum of UA 128.13 <br /> Envelope Heat Load 6,022 Btu/Hour <br /> Figure 1. Sum of UA XAT <br /> _ Air Leakage Heat Load 4,499 Btu/Hour <br /> VolumeX 0.6 XAT X.018 <br /> Above Grade Building Design Heat Load 10,522 Btu/Hour <br /> Air Leakage+Envelope Heat Loss <br /> Building and Duct Heat Load 11,574 Btu/Hour <br /> Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 <br /> Ducts in conditioned space:Sum of Building Heat Loss X 1 <br /> Maximum Heat Equipment Output 16,203 Btu/Hour <br /> Building and Duct Heat Loss X 1.40 for Forced Air Furnace <br /> Building and Duct Heat Loss X 1.25 for Heat Pump <br /> (07/01/13) <br />
The URL can be used to link to this page
Your browser does not support the video tag.