A PROJECT NO. SHEET NO. <br /> r S210708-2XR <br /> 1411%.=.00 PROJECT 10304 1st Dr SE, Everett, WA, 98208 <br /> LONGITUDE SUBJECT Foundation Stabilization/Jacking <br /> ONE TWENTY° <br /> ENGINEERING&DESIGN BY NJ DATE 8/15/21 <br /> LOAD ANALYSIS:IBC 2018-1-STORY U <br /> BUILDING <br /> Typical Pile 8'-0"Span: 4' L/2 4' L/2 <br /> Roof LL(snow ground):25 psf <br /> Floor LL:40psf <br /> Floor/Roof DL:15psf <br /> Wall DL:12psf - - - - - <br /> Stemwall DL:100 psf(8"wall) <br /> Roof Trib: 0.5*28'span=14' <br /> Floor Trib:0.5*20'max span=10' <br /> Deck Trib:0.5*8'=4' <br /> Typical Fir Ht:10'*1story=10'-0" <br /> 2'-2" <br /> Case 2:Uniform Load: <br /> WDL=15psf"(14'+10'+4')+12psr(10')= (18"' 8") <br /> 0.54k1f <br /> WDL(Stemwall)=100psf*2.5ft=.25k1f <br /> y <br /> WsL=25psf*(14')=0.35k1f <br /> WLL=40psf*(10')+60psf*(4')=0.64 klf <br /> Pile and connection requirements per Pile and connection requirements per <br /> WTL=DL+SL+LL= contractor contractor <br /> 0.54k1f+0.35k1f+0.64k1f=1.53 klf(w/o <br /> stemwall) <br /> 0.54k1f+0.25k1f+0.35k1f+0.64k1f=1.8 klf <br /> (w/stemwall) i 8'-0" MAX <br /> Case 1:Point Load(8'-0"span): <br /> PDL=0.54k1f"8'-0"=4.3kips NOTES: <br /> PDL(stemwall)=0.25k1f*8'-0"=2 kips <br /> 1. Both uniform and point loads analyzed in the following calculations.Uniform loads are <br /> PSL=0.351f*8'-0"=2.8 kips assumed to be standard due to load distribution from bearing walls,however,the additional <br /> point load is conservatively considered here for any major beam supports from above. <br /> PLL=0.64k1f*8'-0"=5.1 kips 2. Maximum loading on the grade beam was determined by inspection of the building <br /> PTL(w/o stemwall DL)=1.53k1f*8'-0"= geometry and through conservative assumptions regarding span lengths and support <br /> 12.3 k wall/foundation. All concrete walls assumed full tributary span of floor and roof members. <br /> PTL(w/stemwall DL)=1.8k1f*8'-0"= <br /> 14.4 k <br /> Refer to attached calculations for Conclusion: <br /> analysis. Based on the loading and geometry of the structure we conclude that the foundation <br /> may be stabilized through the use of piles and connections per R&R. These are to be <br /> attached to the stem-wall(grade-beam)at an on-center(o.c.)spacing no greater than <br /> 8'-0". <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.