Laserfiche WebLink
4 3 2 <br />DRAINAGE PLAN <br />N FOR <br />I CHICK=FIL=A EVERETT <br />SECTION 18, TWP. 28 N., RGE 4 EAST, W. M. <br />EVERETT, SNOHOMISH COUNTY, STATE OF WASHINGTON <br />E C��Py <br />40' HIGH ❑ <br />VOLTAGE 3 <br />EASEMEM _ <br />imam SDI - <br />A. <br />- ♦� e a� O <br />SID <br />I / <br />0 15' 30' 60' m'm/- <br />® ad, <br />/'. <br />SCALE: 1"=30' / '! /i ° Y xd'i _ ' �� T -31-i- ❑ <br />DETENTION SYSTEM ;�x,A, a1/ _ - / / J% , qq- - _ �^ O <br />MC-3500 STORMTECH CHAMBERS IN ROCK GALLERY�`` Spy \ f <br />TOTAL CHAMBERS = 185 <br />TOTAL END CAPS = 26 /- ' - ✓ <br />° <br />DRAIN ROCK VOID RATIO = 40% i / -L '° 1 -nj <br />BOTTOM OF CHAMBERS ELEVATION = 499.32 x------ 508 x <br />BOTTOM OF STONE ELEVATION = 498.5] @--s---` ,♦w,- wW ' \ �\ <br />TOP OF CHAMBER ELEVATION = 503.07 <br />5 <br />TOP OF WE STORAGE ELEVATION = 503.57 £,t+<570. ',4� q81•• ' e <br />,X�F� a , <br />TOP OF GRAVEL ELEVATION = 504.W /" � - ;�"� nAi ' ,� m• .. m• <.,ne„n " <br />\EASEMENT 2045683 - S' SNOPUD EASEMENT 1395231 <br />_ _ <br />I S HIGH VOLTAGE /j' - �/ .� eEASEMENT- <br />D EASEMENT._ / 1 n� ` /, �, 36 LF 6" O 3.78R \ - _ s <br />d }/S'� <br />Tam <br />j °'m AREA DRAIN #1 I >� <br />�x ♦`♦ 'yam ' 507 1 S�° $ 'ss� I ss-ffi- <br />- <br />`{� f �•! ' ,` -' ISOLATOR ROW CBS � `,'/ I <br />Rdn <br />8 Z <br />1 I <br />0 48 LF 12" O 0.50% \ 30p LF 11O 1 OOR, <br />C..a ° <br />Ix <br />Ina ` :,� _ <br />" �T - -- �� I g J <br />IL <br />cI0 <br />\ 3 1 O <br />'A <br />4. n p Y <br />' 20 NTERUBW I <br />g• <br />39 LF 12 O 0.54%•,a'n <br />TRNL EASEMENT � I11 <br />4 LF 24 ORO.00R °.a °" `7' STRIP ALONG PUD <br />'yy t' 111111 ^, f UNDERGROUND LINES <br />•a•a s �. EASEMENT 8003050193 <br />41 <br />- A 49 LF 6 O 2.37%' V <br />ice♦ ( <br />I <br />a ' T `DRAINAGE DETAIL 1, SEE THIS SHEET <br />A ad - I10 LF 1�oso%-5p6 38�" 0 1.00%Kid: (. _gip • BDCOq BDCO Yl '.�/ '- zl <br />B " a s \ 33 LF 12 0 5.00% ad WYE#1♦ l f 1 ,•q I <br />'J !IE 50061^(12 N)„!' .._ �_WYE#2 - ,, to 06' 0 1 oox \ <br />1 BO LF 12 O 0.52R ^ 30 IF 6 O 1.70%10 Y <br />1 a ^. �'�4 500.66 (12 N) I fF� % �1 fip•4 � \ C <br />\ LJ <br />•j n ° ' 22 LF 12a 0 0.50R `14 <br />�Ns ♦ _ -12* <br />-- - ______ _ __ ___ _ ____ <br />''' 1___-__-____________________________ ----- __ _________________ ___________ -------------------------------------------I j 's <br />Ex CB #1 W. MALL DR (PRIVATE) <br />STORM DRAIN GENERAL NOTES: <br />1. ALL IMPROVEMENTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE <br />PROVISIONS OF THE CURRENT CITY ORDINANCE AND STANDARD PLANS. THE <br />IMPROVEMENTS ARE SUBJECT TO THE OBSERVATION AND APPROVAL OF THE <br />PUBLIC WORKS DEPARTMENT. <br />2. ALL STORM DRAIN LINES SHALL BE PVC SDR-35 UNLESS OTHERWISE NOTED. <br />DRAIN PIPING LABELED DI SHALL BE CLASS 52 DUCTILE IRON PIPE. ALL STORM <br />DRAIN PIPES SHALL BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS AND <br />A CITY STANDARDS. <br />EXCAVATION NOTE <br />GEOTECHNICAL ENGINEER MUST OBSERVE AND APPROVE THE EXCAVATION BASE <br />BEFORE THE CONTRACTOR BACKFILLS THE STORMTECH SYSTEM. <br />4 3 2 <br />STORM STRUCTURES <br />TABLE <br />AREA DRAIN /1, 8" NYLOPIAST DRAIN <br />W/DOMED GRATE <br />RIM=506.95 <br />IE=504.45 (6" W) <br />CB #3, TYPE 1, W/STANDARD GRATE <br />RIM=505.29 <br />IE=50I (12" E) <br />CBr1, TYPE 2-54" W/SOLID LID <br />FLOW CONTROL STRUCTURE <br />RIM 505.36 <br />IE 49932 (24" N) <br />IE 49932 (12" SE) <br />CBr2, TYPE 2 48" W/SOLID LID <br />RIM 505 62 <br />IE 50032 (12" E) <br />IE 500.24 (8" S) <br />IE=499.32 (24" N) <br />CBN3, TYPE 2-48" W/SOLID LID <br />FLOW SPLITTING STRUCTURE <br />RIM 506.18 <br />IE 500.49 (12- S) <br />IE 502.34 (12" NE) <br />IE 500.49 (8" SW) <br />IE 500.49 (12" W) <br />CBN4, TYPE I, W/SOUD LOCKING LID <br />RIM=504.97 <br />IE=500.77 (12" E) <br />IE=500.77 (12" W) <br />IE=50I (12" N) <br />CBr5, TYPE I, W/STANDARD GRATE <br />RIM 504.12 <br />IE 501.12 (12- E) <br />CBr6, TYPE I, W/STANDARD GRATE <br />RIM=504.44 <br />IE 501.44 (12" W) <br />CB#7, TYPE I, W/STANDARD GRATE <br />RIM 505.98 <br />IE 502.56 (12" N) <br />IE 502.56 (12" SW) <br />CBNB, TYPE I, W/STANDARD GRATE <br />RIM-505.85 <br />IE 502.80 (12" N) <br />IE 502.80 (12- S) <br />CB/9. TYPE 1, W/STANDARD GRATE <br />RIM 506.38 <br />IE 503.09 (6" E) <br />IE 503.09 (12- S) <br />CB/10, TYPE 2-48", W/SOLID LOCKING LID <br />RIM 505.80 <br />IE 500.43 (8" NE) <br />IE 500.43 (8" W) <br />CB/11, TYPE 2 48'. W/SOLID LOCKING LID <br />RIM 505 35 <br />IE 50029 (8" E) <br />IE 50029 (8" N) <br />EX CB r1, TYPE 1, W/STANDARD GRATE <br />RIM 503 05 <br />IE 49890 (12" NW) <br />IE 49890 (12" SW) <br />MWS MWS, L4 6 <br />RIM 505.43 <br />IE 500.33 (8" E) <br />IE 500.33 (8" W) <br />OWS, CPS 660 SA OR EQUAL <br />RIM 505 60 <br />IE 500.38 (8" E) <br />IE=500.38 (8" W) <br />RD r1, W/ADA RATED LID <br />RIM=506.97 <br />IE=504.50 (6" S) <br />■ <br />■ 5 LF 24"00 <br />t.. <br />CBI <br />■ <br />Qa <br />■ <br />0 <br />0 <br />El <br />0 <br />STORM STRUCTURES <br />TABLE <br />RD 02, W/ADA RATED LID <br />RIM=506.96 <br />IE=504.20 (6" N) <br />IE=504.20 (6" S) <br />RD R3, W/ADA RATED LID <br />RIM=506.93 <br />IE=503.84 (6" N) <br />IE=503.84 (6" S) <br />RD/4, W/TRAFFIC RATED LID <br />RIM 504.77 <br />IE 50227 (6" N) <br />ROILS. W/TRAFFIC RATED LID <br />RIM 50499 <br />IE 502.49 (6" N) <br />SDCO #I, W/TRAFFIC RATED LID <br />RIM=505.18 <br />IE 502.68 (6" N) <br />IE 502.68 (6" W) <br />SDCO 112, W/TRAFFIC RATED LID <br />RIM=504.8] <br />IE 502.17 IS" E) <br />E 502.17 (6- S) <br />IE 502.17 (6" W) <br />SDCO 03, W/TRAFFIC RATED LID <br />RIM=505.09 <br />IE=501.79 (6" E) <br />IE=501.79 (6" S) <br />IE=501.79 (6- W) <br />MODULAR WETLAND <br />O, MODULAR WETLAND <br />MODEL MWS-L-4-6-V <br />SEE DETAIL SHEET 3/C5.2 <br />OIL/WATER SEPARATOR <br />O OIL/WATER SEPARATOR MODEL 660 CPS <br />SEE DETAIL I/C5.2 <br />3 <br />f3 <br />❑O DRAINAGE KEYNOTE <br />1. CONNECTION FOR ROOF DRAIN CONFIRM DOWNSPOUT LOCATIONS AND <br />TIE-IN POINTS WITH PLUMBING PLANS. SEE BUILDING DOWNSPOUT DETAIL <br />10/C4.1. <br />2. CONTRACTOR TO POTHOLE AND CONFIRM ELEVATION OF PIPE AT <br />PROPOSED CONNECTION POINT PRIOR TO CONSTRUCTION. CONTRACTOR TO <br />NOTIFY BARGHAUSEN IMMEDIATELY WITH ANY DISCREPANCIES. C <br />3. PROPOSED FLOW CONTROL STRUCTURE. SEE DETAIL 2/C5.3. <br />4. PROPOSED FLOW SPLITTING STRUCTURE. SEE DETAIL I/C5.3. <br />CBt3 : B <br />12 LF 8"`0 OSI0 ■ ■ <br />33 LF 12" O 0.50% ■ <br />10 LF B" O 0.50% <br />Cm <br />8 LF 8" O 0.50% <br />9 LF8"00.50% ■ <br />IN �SOS <br />■ <br />$ O 0 10 LF B" O 0.50% ■ <br />■ <br />24 LF 12" O 0.50% ■ <br />■ A <br />■■■■■■■■■■■■■■■■■ ■f <br />RAINAGE DETAIL 1 Know what's below. <br />C3.0 SCALE: I" <br />p Call before you dig. <br />Dial 811 <br />1 <br />a W- <br />�oOO <br />0 <br />O ��0 000 Oro <br />Chick-fil-A <br />5200 Buffington Road <br />Atlanta, Georgia 30349- <br />2998 <br />[i] <br />Barghausen <br />Consulting Engineers, Inc. <br />18215 72nd Avenue South <br />Kent, WA98032 <br />425.251.6222 <br />barghausen.com <br />ad <br />Q <br />JJ�J <br />�J L�CD <br />WI-00 <br />> LU <br />�~ rVW� <br />�W WW1= <br />W j LU <br />=jQ�w <br />VW ��w <br />FSR#04669 <br />BUILDING TYPE/SIZE'. <br />RELEASE: <br />REVISION SCHEDULE <br />NO. DATE DESCRIPTION <br />CONSULTANT PROJECT A 21637 <br />PRINTED FOR <br />DAM 4/26/2022 <br />DRAWN BY ADS <br />and nail JI IIN <br />In <br />.� .���,aodS.dad annBab,m�anf.. <br />M]GT11P&jejj I•I. <br />SHEET NUMBER <br />C3.0 <br />