Laserfiche WebLink
GEROU HOME REMODELING <br /> • <br /> • <br /> Alterations Worksheet-2018 Washington State Energy Code R503.1.1 Building envelope.Building envelope assemblies that are pert of the alteration shall comply with Section R402.1.1 <br /> Project Information Contact Inky-matron or R402.1.4,Sections R402.2.1 through R402.2.11,R402.3.1,R402.3.2,R402.4.3 and R402.4.4. <br /> GEROU HOME REMODELING Steve Hall Exception:The following alterations need not comply with the requirements for new construction provided the <br /> 1130 75TH St SE 360.981.3838 energy use of the building is not Increased: <br /> Everett WA 98203 reviveprooernes@comcast.ttet 1. Storm windows installed over existing fenestration. <br /> 2. Existing ceiling,wail or floor cavities exposed during carseUcdon provided that these cavities are filled with <br /> The WSEC requirements for alterations are located in Chapter 5 of the code text. Insulation.244 framed walls shall be insulated to a minimum of R-15 and 2e6 framed walls shall be Insulated to e <br /> Alterations(remodels)do not need to obtain energy credits from Table R406.3 minimum of R-21. <br /> 3. Construction where the existing roof,wall or floor cavity is not exposed. <br /> Additions must meet the requirements for new construction.This includes nonconditioned space being 4. Roof recover. <br /> altered to become conditioned space. 5. Roofs without insulation in the cavity and where the sheathing or insulation is exposed during reroofing <br /> shall be insulated either above or below the sheathing. <br /> Will the Wall cayitie6 be exposed? 6. Surfaceapplled window film Installed on existing single pane fenestration assemblies to reduce solar heat <br /> P Yes r No gain provided the code does not require the glazing fenestration to be replaced. <br /> If yes: Exposed wall cavities must be Insulated- <br /> 2 X 4 wall studs require R-16 insulation R503.1.1.1 Replacement fenestration.Where some or all elan existing fenestration unit is replaced with a new fenestration <br /> 2 X 6 wall studs require R-21 insulation product,including sash and glazing,the replacement fenestration unit shall meet the applicable requirements for U-facto <br /> and SHGC In Table R402.1.1.Where more than one replacement fenestration unit Is being installed,an area-welted <br /> Will the roof/ceiling framing cavities or attic be exposed? r Yes PNo average of the U-factor and SHGC of all replacement fenestration shall be permitted to be used to demonstrate compliance. <br /> R503.1.2 Heating and cooling systems.New heatin&cooling and duct systems that are part of the <br /> If yes: Exposed roof/ceiling assemblies must be insulated- alteration shall comply with Section R403. <br /> Vaulted ceilings: Insulate to the full depth of the framing member Exceptions: <br /> 1.Where ducts from an existing heating and cooling system are extended,duct systems with less than 40 Ilnear feet In <br /> while allowing for the minimum 1"ventilated space uncondidoned spaces shall net be required to be tested in acxrdance with Section R403.2.2. <br /> 2.Existing duct systems constructed,Insulated or sealed with asbestos. <br /> Flat ceilings: Install R-49 insulation or what the attic space can <br /> accommodate based on the roof pitch <br /> Will the floor framing cavities be exposed? FYes r-No R502.1.1.2 Heating end cooling systems.New heating cooling and duct systems that are part of the addition shall comply <br /> 9103. <br /> If yes: Exposed floor cavities must be Insulated to R-30 with Section Exception:The following need not comply with the testing requirements of Section R403.3.3: <br /> 1. Additions of less than 750 square feet. <br /> Are the windows and/or doors being replaced? P Yes r No 2. Duct systems that are documented to have been previously sealed as confirmed through field verification <br /> (includes bath window or door and frames) and diagnostic testing in accordance with procedures in WSU RS-33. <br /> If yes: New windows and doors must have an area weighted average U-factor of 50.30 3. Ducts with less than 40 linear feet in unconditioned spaces. <br /> 4. Existing duct systems constructed,insulated or sealed with asbestos. <br /> Will the heating or cooling system be replaced? P Yes r No <br /> R503.1.3 Service hot water systems.New service hot water systems that are part of the alteration shall comply with Section <br /> If yes: New equipment must meet current requirements and S403.5. <br /> ducts need to be tested <br /> R503.1.4 lighting.New lighting systems that are part of the alteration shall comply with Section R404.1. <br /> Will the hot water system be altered? P Yes P'No Exception:Alterations that replace less than 50 percent of the luminaires In a space,provided that such <br /> alterations do not Increase the installed interior lighting power. <br /> If yes: New water heating equipment must meet current code requirements <br /> R503.2 Charge in space conditioning.Any nronconditioned or low-energy space that Is altered to become cordltionedspace <br /> Are more than 50%of the light fixtures being changed? P Yes I—No shall be required to be brought Into full compliance with this code. <br /> If yes: 75%of all lamps must be high efficacy <br /> (LED or CFL) <br /> REVIVE PROPERTIES LLC <br /> scale: 1/4-=p0• erreovcoer. oeuwaer SFH <br /> ores. 4/1 pzT REVISED <br /> ENGERGY WORKSHEET <br /> DRAWING AN HOER <br />