'REQUIRED NUMBER AND LOCATION OF MODEL REQUIRED NUMBER AND LOCATION OF MODEL <br /> 1100 V"SERIES BRACES FOR 4/12&5/12 1100"V" SERIES BRACES FOR 6/12&7/12 <br /> SINGLE SECTION DOUBLE WIDES TRIPLEWIDES SINGLESECTiON DOUBLE WIDES TRIPLE WIDES <br /> C -- C — -E] <br /> i11 i-6.-...oio I II i-- IL 41-- AN. •• •• <br /> SINGLE SECTION DOUBLE WIDES ALL WIDTHS DOUBLE WIDES ALL WIDTHS SINGLESECTiON DOUB LE WIDES ALL WIDTHS DOUBLE WOES ALL WIDTHS <br /> ALL WIDTHS up to 76' up to 76' ALL WIDTHS up to 76' up to 76' <br /> upto76' upto76' <br /> LEGEND: (Length of house is actual box size) <br /> 1.- I - Approximate location of the system(See note H) <br /> 2.- 3-- - Location of ASF Model 1100"V' (Lateral and Longitudinal Bracing)or 1100 T(Lateral only) <br /> 3.-0- - Location of additional ASF Model 1100 T"V'System(Lateral only)for homes exceeding 76'in length or with roof pitch between 4.37/12(20 degrees) <br /> and 5/12,the additional system is to be installed at approximately the midpoint of the house and may be installed at either exterior beam. <br /> 4.- 0 - Installation of single wide homes require two(2)anchors per side located not more than ten(10)feet from each end(with a minimum of 3150 load rating) <br /> 5.-1 "- - Location of additional ASF Model 1100 T"V'System(Lateral only)for homes exceeding 76'in length,sidewall height exseding 96"or with roof pitch <br /> between 6/12&7/12 the additional system is to be Installed at approximately the midpoint of the house and may be installed at either exterior beam. <br /> NOTE: <br /> a) Installation of the longitudinal system eliminates the need for the longitudinal anchors. <br /> b) Installation of the transverse system eliminates the need for all anchors,diagonal frame ties and stabilization plates exc ept when noted. <br /> (Legend#5&note C) <br /> c) All other home manufacturer's instructions for installation of stabilizing devices must be followed, including installation of vertical tie-down <br /> anchors,and mating line column,shear wall or center-line tie-down anchors.NOTE WIND ZONE II: ALL VERTICAL ANCHORS (NOT TO <br /> EXCEED 8'SPACING)MUST BE INSTALLED PER MANUFACTURER's INSTALLATION INSTRUCTIONS! <br /> d) If the home manufacturer's installation Instructions are not available,the home must be Installed in accordance with any state promulgated <br /> rules or as required by the authority having jurisdiction. <br /> e) If bolts,nuts and tech screws are lost,they may be replaced as long as they meet or exceed the specs for OTI ASFS hardware. <br /> f) When the length of home exceeds 76',sidewall height exceeds 96"or the roof pitch Is between 4.37/12(20 degrees)and 5/12,add 1 transverse system <br /> (see location diagrams above)6/12:a total of 4Transverse&3 Longitudinal systems are needed&7/12:a total of 5 Tra nsverse&3 Longitudinal systems <br /> are needed. (Longitudinal portion only required when longitudinal bracing is required by home manufacturer). <br /> g) An alternative method using the 1100 CVD anchors(dry set)or 1100 CVW(wet set)may be used on a footing size of 16'diam eter X 24"depth. These <br /> brackets are designed for lateral and longitudinal protection. <br /> h) It is recommended that the systems be installed at the end pier In from each end of the house. However,they may be Insta lied at any location at least <br /> 2 feet,but not more than Y/s the house length,in from the ends of the home. <br /> STATE OF MICHIGAN ONLY: As required by Section 1805.2 of the 200 Michigan Building Code,the depth of the footer shall be a minimum depth of <br /> 42 inches below grade,except that the authority having jurisdiction may approve a lesser depth based on known prevailing soil and weather <br /> conditions,or as provided by the exception under Section 1805.2.1 of the Code. <br /> STATE OF ALABAMA ONLY: Maximum pier height is limited to 32"with pier defined <br /> in the Alabama Regulation as"that portion of the support system between the top of <br /> the footing and the bottom of the pier cap." C i f� EVERETT <br /> The State of Alabama limits the use of this t i system to H.U.D labeled homes. REVSEWE© Fvtt11 <br /> fl PERM! ' ilm•Crimr <br /> STATE OF NORTH CAROLINA ONLY: 1 <br /> Tubing must be galvanized and,when I-Transverse Arm,I-Beam Connector <br /> the manufacturer's installation �1 r. <br /> instructions are not available, <br /> vertical wall tie-downs must be \ , . _ <br /> installed not to exceed 8-feet <br /> on center. (Wind Zone II) F- "V"Brace I-Beam <br /> STATE OF IDAHO ONLY: �,,,. .�" <br /> Concrete must be a ..I H'TransverseTop(1.25")Arm Connectors <br /> loili- <br /> minimum of 8"In depth. <br /> f` Bottom(1.5`) <br /> _. 11101 <br /> :lji/gllill.l.°LlrklIl- <br /> .4.•.' , /nER. <br /> Nj ��' TECHNOLOGIES INC. 1, <br /> 41 D-Pan Transverse Connector E-"V"Brace Tube <br /> Phone:(800)284-7437 or D(W)or D(D)Concrete (1.5") <br /> II <br /> Fax:(931)796-8811 Transverse Connector Nil <br /> olivsrtechnologies.com I01 <br /> 467 Swan Avenue,Hohenwald,TN 38462 B-Ground Pan or <br /> C-Concrete Base(le000110.' J- Pan V Bracket or <br /> footer,runner,etc.) J(W)or J(D)Concrete <br /> "V"Bracket <br /> Rovlcorl fl /17/1111(1 PATFNT# 66q41.511 and nthpr natPnts npndinn Panda a/a <br /> ©2 <br />