PROPOSED ANTENNA
<br /> I
<br /> EXISTING
<br /> ANTENNAS
<br /> PROPOSED JUMPER
<br /> TO ANTENNA
<br /> PROPOSED CONNECTOR AND A ..,,,
<br /> TO EXISTING ■ WEATHERPROOFING KIT
<br /> ANTENNA MASTS ��T t 3/8"X 1-1/2"SS BOLT 3/8"SS LOCK WASHER AMERICANTIO I ERV Q
<br /> ' 1 I!,� PROPOSED WEATHERPROOFING KIT - (EACH SIDE) {EACH SIDE) ATC TOWER SERVICES,LLC (.
<br /> EXISTING COAX ■ ��� ��' 3500 REGENCY PARKWAY
<br /> GROUND KITS 1 ti� til
<br /> 1
<br /> PROPOSED CABLE © SUITE 100 =
<br /> GROUND KIT r� ( CARP,NC 27518 `
<br /> I
<br /> , ,,,,.,
<br /> ANTENNA CABLE 21/2"0 MAX ''�- ( )
<br /> J. PHONE: 916 468-0112 a
<br /> ,,„„iii
<br /> 04
<br /> L!� �� COA:3408
<br /> f • 1III ANTENNA CABLE TO it JIM
<br /> O
<br /> i i �� t I CABINET(TYP.) oli �'Q Q o:
<br /> 1 `� I -�'Q - Fl., CORE ONEi I r, I s �r�I GROUNDING KIT PER CABLE Q °
<br /> PROPOSED#6 AWG --F1... 01, \ ` r 1i MANUFACTURER'S RECOMMENDATIONS ° u
<br /> STRANDED CU \ '-," �` �\ � I (ANDREW OR APPROVED EQUAL) ' S3 kl CONSULTING USA A
<br /> I #6 AVVG STRANDED CU C� ' �'� 0
<br /> WIRE WITH GREEN,600V, �` / ' -® ' O
<br /> THWN INSULATION `�, \ \ \ i / WIRE WITH GREEN,600V, 11(
<br /> '� Q 4515 S.MCCLINTOCK DRIVE,SUITE 217
<br /> TO PROPOSED OVP BOX .y�\\ V. \It i i i THWN INSULATION #6 AWG STRANDED COPPER GROUND ' -n ''® ' TEMPE,AZ 85282
<br /> WIRE(GROUNDED TO GROUND BAR / l y
<br /> GROUNDING + )
<br /> CONNECTION TO 4I
<br /> ,�- 1/4"X 4"X 6"GROUND BAR
<br /> EXISTING TMAs I r (ERiCO P/N:EGBA14406CC OR EQUAL)
<br /> YY I I I I . I I '1.----------__. REV. DESCRIPTION BY DATE
<br /> EXISTING GROUNDING IGROUND BAR MOUNTED TWO-HOLE LUG,TO BE USED
<br /> CONNECTION TO NEAR/BELOW ANTENNA © �� a PRELIM REG 07/14/21
<br /> LIGHTNING OBE INSTALLED IF �� WITH#2 AVVG BCW
<br /> I (T ii� TO GROUND BAR (LOWER TOWER GROUND , 100%CD REG 07/14/21
<br /> —
<br /> PROTECTION SYSTEM i REQUIRED) BAR ONLY) Q
<br /> NOTES: J TO EQUIPMENT A
<br /> 1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS.SLIGHT GROUND BAR NOTES: A
<br /> ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS.THE GROUND KIT NOTES: ATC SITE NUMBER:
<br /> CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT 1. GROUND BAR KITS COME WITH ALL HARDWARE,NUTS,BOLTS,
<br /> CONSTRUCTION MANAGER OF ANY CONFLICTS. GROUND WIRE DOWN TO GROUND BAR. WASHERS,ETC.EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 83067
<br /> 2. SITE GROUNDING SHALL COMPLY WITH VERIZON GROUNDING STANDARDS,LATEST 2. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT(ANDREW PART
<br /> EDITION,AND COMPLY WITH VERIZON GROUNDING CHECKLIST,LATEST VERSION.WHEN NUMBER 221213)AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS. 2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER. ATC SITE NAME:
<br /> NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. SOUTH EVERETT
<br /> CD TYPICAL ANTENNA GROUNDING DIAGRAM O CABLE GROUND KIT CONNECTION DETAIL O TOWER GROUND BAR DETAIL VERIZON SITE NAME:
<br /> SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S. WASE SOUTH EVERETT
<br /> SITE ADDRESS:
<br /> - �� 709 80ST SW
<br /> 1/4"0 HILTI KWIK BOLT III EVERETT,WA 98203
<br /> �% SEAL:
<br /> 3/8"THREADED INSULATOR I �� 3/8"X 3/4"SS
<br /> WHERE INDICATED ' j BOLT(TYP.) v.f t� %
<br /> 06,
<br /> ( ( GROUND BAR I�T,�j4
<br /> 4 t"ti''/'-`" MOUNTING BRACKET ` G'\f3
<br /> GROUNDING NOTES: �Q
<br /> o
<br /> o ' ` �` 9.)GROUND BARS SUPPLIED BY OWNER AND INSTALLED BY ' e �� y
<br /> ® I� r 1.)UNDERGROUND AND OVERHEAD UTILITY LENGTHS TO BE ✓,�"
<br /> '� °®® J i DETERMINED FROM SITE PLAN. CONTRACTOR. \
<br /> Q ® ` 10.)ALL BENDS IN GROUNDING SYSTEM MUST BE SMOOTH \ $ .>
<br /> �'' 2.)SEE ELECTRICAL SPECIFICATIONS SECTION 16000 FOR ALL -O \
<br /> AND WELL ROUNDED AND MAINTAIN BENDING RADIUS.
<br /> r,q- ---®®°°Q®® 1 Ji �,46 ' ELECTRICAL AND GROUNDING INSTALLATION REQUIREMENTS, 56058 w
<br /> 'a Q®® °Q®® -��l . toll 0, -' 11.)SEE SITE PLAN FOR COAXIAL ROUTING THIS SHEET IS ��\GIST�gF�/\�
<br /> ifr �- Q ®® Q Q®® ' . - - DRAWING.
<br /> ORIENTATION OF SITE LAYOUT SEE SITE PLAN, INTENDED FOR GROUNDING CLARITY ONLY AND IS SCHEMATIC eSS n t, ! ""�t`\J�
<br /> QQ®® QQ®r
<br /> `y�G�� '�( , IN DETAIL. /ONA4
<br /> �'�- °a®® ° -- it lie 4.)UDA CTORET FURNISHED BY OWNER AND INSTALLED BY 12.)GROUND KITS SHALL BE INSTALLED BETWEEN 8"-18"OF
<br /> �' !� Q Q®® ALL CONNECTORS.
<br /> (� '- ° �� 5.)GROUND KITS PROVIDED BY OWNER SHALL BE
<br /> y-+ /— 1/4"X 4"X 12" 13.)TOWER FOUNDATION DESIGN BY OWNER,INSTALLED BY
<br /> (I :, - a I' GALVANIZED BUSS RETROFITTED TO ACCOMMODATE 2 HOLE LUG CONNECTION CONTRACTOR. verizon1
<br /> 1:39-
<br /> t AND APPROPRIATE LENGTH.
<br /> ' 6.)CONTRACTOR RESPONSIBLE TO PROVIDE OWNER 14.)ADDITIONAL GROUND KITS TO BE PLACED AT 100'WHEN
<br /> TWO-HOLE LUG,TO BE USED ANTENNA CENTERLINE IS 200'OR ABOVE.
<br /> WITH#2 AWG BCW CERTIFICATION OF RESISTIVITY TESTING.
<br /> 3/8"SS LOCK 15.)ALL CONDUITS TO BE SEALED W/SILICONE TO PROVIDE A DATE DRAWN: 07/14/21
<br /> WASHER(TYP.) I 7.)GROUND RODS TO BE INSTALLED AT 10'CENTERS. WATER TIGHT SEAL. ATC JOB NO: 13671799_G5
<br /> 8.)ALL GROUND LEADS TO BE SLEEVED IN 3/4"0 SCHEDULE 40 CUSTOMER ID: WASE SOUTH EVERETT
<br /> GROUND BAR NOTES PVC CONDUIT AND SEALED W/SILICON.
<br /> CUSTOMER#: 102287
<br /> 1. GROUND KITS COME WITH ALL HARDWARE,NUTS,BOLTS,WASHERS,ETC.
<br /> EXCEPT THE STRUCTURAL MOUNTING MEMBER(S).
<br /> 2. GROUND BAR SHALL BE BOLTED TO STRUCTURAL MEMBER OR GROUNDING DETAILS
<br /> ANCHORED TO CONCRETE SLAB W/HILTI KVMK BOLT III.
<br /> 0
<br /> MAIN GROUND BAR DETAIL SHEET NUMBER: REVISION:
<br /> SCALE N.T.S. E-501 0