Laserfiche WebLink
PROPOSED ANTENNA <br /> I <br /> EXISTING <br /> ANTENNAS <br /> PROPOSED JUMPER <br /> TO ANTENNA <br /> PROPOSED CONNECTOR AND A ..,,, <br /> TO EXISTING ■ WEATHERPROOFING KIT <br /> ANTENNA MASTS ��T t 3/8"X 1-1/2"SS BOLT 3/8"SS LOCK WASHER AMERICANTIO I ERV Q <br /> ' 1 I!,� PROPOSED WEATHERPROOFING KIT - (EACH SIDE) {EACH SIDE) ATC TOWER SERVICES,LLC (. <br /> EXISTING COAX ■ ��� ��' 3500 REGENCY PARKWAY <br /> GROUND KITS 1 ti� til <br /> 1 <br /> PROPOSED CABLE © SUITE 100 = <br /> GROUND KIT r� ( CARP,NC 27518 ` <br /> I <br /> , ,,,,., <br /> ANTENNA CABLE 21/2"0 MAX ''�- ( ) <br /> J. PHONE: 916 468-0112 a <br /> ,,„„iii <br /> 04 <br /> L!� �� COA:3408 <br /> f • 1III ANTENNA CABLE TO it JIM <br /> O <br /> i i �� t I CABINET(TYP.) oli �'Q Q o: <br /> 1 `� I -�'Q - Fl., CORE ONEi I r, I s �r�I GROUNDING KIT PER CABLE Q ° <br /> PROPOSED#6 AWG --F1... 01, \ ` r 1i MANUFACTURER'S RECOMMENDATIONS ° u <br /> STRANDED CU \ '-," �` �\ � I (ANDREW OR APPROVED EQUAL) ' S3 kl CONSULTING USA A <br /> I #6 AVVG STRANDED CU C� ' �'� 0 <br /> WIRE WITH GREEN,600V, �` / ' -® ' O <br /> THWN INSULATION `�, \ \ \ i / WIRE WITH GREEN,600V, 11( <br /> '� Q 4515 S.MCCLINTOCK DRIVE,SUITE 217 <br /> TO PROPOSED OVP BOX .y�\\ V. \It i i i THWN INSULATION #6 AWG STRANDED COPPER GROUND ' -n ''® ' TEMPE,AZ 85282 <br /> WIRE(GROUNDED TO GROUND BAR / l y <br /> GROUNDING + ) <br /> CONNECTION TO 4I <br /> ,�- 1/4"X 4"X 6"GROUND BAR <br /> EXISTING TMAs I r (ERiCO P/N:EGBA14406CC OR EQUAL) <br /> YY I I I I . I I '1.----------__. REV. DESCRIPTION BY DATE <br /> EXISTING GROUNDING IGROUND BAR MOUNTED TWO-HOLE LUG,TO BE USED <br /> CONNECTION TO NEAR/BELOW ANTENNA © �� a PRELIM REG 07/14/21 <br /> LIGHTNING OBE INSTALLED IF �� WITH#2 AVVG BCW <br /> I (T ii� TO GROUND BAR (LOWER TOWER GROUND , 100%CD REG 07/14/21 <br /> — <br /> PROTECTION SYSTEM i REQUIRED) BAR ONLY) Q <br /> NOTES: J TO EQUIPMENT A <br /> 1. THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS.SLIGHT GROUND BAR NOTES: A <br /> ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS.THE GROUND KIT NOTES: ATC SITE NUMBER: <br /> CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT 1. GROUND BAR KITS COME WITH ALL HARDWARE,NUTS,BOLTS, <br /> CONSTRUCTION MANAGER OF ANY CONFLICTS. GROUND WIRE DOWN TO GROUND BAR. WASHERS,ETC.EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 83067 <br /> 2. SITE GROUNDING SHALL COMPLY WITH VERIZON GROUNDING STANDARDS,LATEST 2. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT(ANDREW PART <br /> EDITION,AND COMPLY WITH VERIZON GROUNDING CHECKLIST,LATEST VERSION.WHEN NUMBER 221213)AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS. 2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER. ATC SITE NAME: <br /> NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. SOUTH EVERETT <br /> CD TYPICAL ANTENNA GROUNDING DIAGRAM O CABLE GROUND KIT CONNECTION DETAIL O TOWER GROUND BAR DETAIL VERIZON SITE NAME: <br /> SCALE:N.T.S. SCALE:N.T.S. SCALE:N.T.S. WASE SOUTH EVERETT <br /> SITE ADDRESS: <br /> - �� 709 80ST SW <br /> 1/4"0 HILTI KWIK BOLT III EVERETT,WA 98203 <br /> �% SEAL: <br /> 3/8"THREADED INSULATOR I �� 3/8"X 3/4"SS <br /> WHERE INDICATED ' j BOLT(TYP.) v.f t� % <br /> 06, <br /> ( ( GROUND BAR I�T,�j4 <br /> 4 t"ti''/'-`" MOUNTING BRACKET ` G'\f3 <br /> GROUNDING NOTES: �Q <br /> o <br /> o ' ` �` 9.)GROUND BARS SUPPLIED BY OWNER AND INSTALLED BY ' e �� y <br /> ® I� r 1.)UNDERGROUND AND OVERHEAD UTILITY LENGTHS TO BE ✓,�" <br /> '� °®® J i DETERMINED FROM SITE PLAN. CONTRACTOR. \ <br /> Q ® ` 10.)ALL BENDS IN GROUNDING SYSTEM MUST BE SMOOTH \ $ .> <br /> �'' 2.)SEE ELECTRICAL SPECIFICATIONS SECTION 16000 FOR ALL -O \ <br /> AND WELL ROUNDED AND MAINTAIN BENDING RADIUS. <br /> r,q- ---®®°°Q®® 1 Ji �,46 ' ELECTRICAL AND GROUNDING INSTALLATION REQUIREMENTS, 56058 w <br /> 'a Q®® °Q®® -��l . toll 0, -' 11.)SEE SITE PLAN FOR COAXIAL ROUTING THIS SHEET IS ��\GIST�gF�/\� <br /> ifr �- Q ®® Q Q®® ' . - - DRAWING. <br /> ORIENTATION OF SITE LAYOUT SEE SITE PLAN, INTENDED FOR GROUNDING CLARITY ONLY AND IS SCHEMATIC eSS n t, ! ""�t`\J� <br /> QQ®® QQ®r <br /> `y�G�� '�( , IN DETAIL. /ONA4 <br /> �'�- °a®® ° -- it lie 4.)UDA CTORET FURNISHED BY OWNER AND INSTALLED BY 12.)GROUND KITS SHALL BE INSTALLED BETWEEN 8"-18"OF <br /> �' !� Q Q®® ALL CONNECTORS. <br /> (� '- ° �� 5.)GROUND KITS PROVIDED BY OWNER SHALL BE <br /> y-+ /— 1/4"X 4"X 12" 13.)TOWER FOUNDATION DESIGN BY OWNER,INSTALLED BY <br /> (I :, - a I' GALVANIZED BUSS RETROFITTED TO ACCOMMODATE 2 HOLE LUG CONNECTION CONTRACTOR. verizon1 <br /> 1:39- <br /> t AND APPROPRIATE LENGTH. <br /> ' 6.)CONTRACTOR RESPONSIBLE TO PROVIDE OWNER 14.)ADDITIONAL GROUND KITS TO BE PLACED AT 100'WHEN <br /> TWO-HOLE LUG,TO BE USED ANTENNA CENTERLINE IS 200'OR ABOVE. <br /> WITH#2 AWG BCW CERTIFICATION OF RESISTIVITY TESTING. <br /> 3/8"SS LOCK 15.)ALL CONDUITS TO BE SEALED W/SILICONE TO PROVIDE A DATE DRAWN: 07/14/21 <br /> WASHER(TYP.) I 7.)GROUND RODS TO BE INSTALLED AT 10'CENTERS. WATER TIGHT SEAL. ATC JOB NO: 13671799_G5 <br /> 8.)ALL GROUND LEADS TO BE SLEEVED IN 3/4"0 SCHEDULE 40 CUSTOMER ID: WASE SOUTH EVERETT <br /> GROUND BAR NOTES PVC CONDUIT AND SEALED W/SILICON. <br /> CUSTOMER#: 102287 <br /> 1. GROUND KITS COME WITH ALL HARDWARE,NUTS,BOLTS,WASHERS,ETC. <br /> EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). <br /> 2. GROUND BAR SHALL BE BOLTED TO STRUCTURAL MEMBER OR GROUNDING DETAILS <br /> ANCHORED TO CONCRETE SLAB W/HILTI KVMK BOLT III. <br /> 0 <br /> MAIN GROUND BAR DETAIL SHEET NUMBER: REVISION: <br /> SCALE N.T.S. E-501 0 <br />