• GAS METER LOCATED IN PROXIMITY OF THE PV INSTALLATION,LOAD CENTER,AND/OR AMBIENT TEMPERATURE SPECIFICATIONS SOLAR MODULE SPECIFICATIONS <br /> DISCONNECTS.DISCONNECTS SHALL BE LOCATED IN COMPLIANCE WITH UTILITY AND THE AHJ <br /> (AUTHORITY HAVING JURISDICTION).PV INSTALLATION SHALL COMPLY WITH ALL APPLICABLE CONDUCTOR CONDUCTOR TEMPERATURE #OF LUM10 <br /> CODES. RECORD AMBIENT TEMP TEMPERATURE TEMPERATURE MANUFACTURER/MODEL# VMP IMP VOC ISC COEFFICIENT <br /> • WIRE RATED AND AMPACITY CALCULATED @ 90°C FOR ROOFTOP INSTALLATION AND ATTIC RUN LOW TEMP (HIGH TEMP 2%) RATE(ON RATE(OFF OF Voc MODULES <br /> TO INVERTER. ROOF) ROOF) HANWHA Q CELLS Q.PEAK DUO <br /> • PER NEC REQUIRMENTS GROUNDING CONDUCTORS SMALLER THAN 6AWG SHALL BE BLK ML-G10+(400W) 37.13 10.77 45.30 11.14 -0.27%/K 18 <br /> PROTECTED IN A CONDUIT,RACEWAY,OR ARMORED PROTECTIVE SHEATHING(NEC 250.64). -5° 26° 90° 75° <br /> • THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL AS THE MODULE DIMENSION 74.0"L x 41.10"W x 1.26"D <br /> NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26. <br /> • ANY CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT.(NEC INVERTER SPECIFICATIONS <br /> 300.6 C1,310.8 D). SERVICE INFO. INTERCONNECTION NOMINAL OUTPUT NOMINAL OUTPUT <br /> • ROOM FOR EQUIPMENT WITHIN 5 FEET FROM MSP. 120%RULE-NEC 705.12(b)(3)(2) MANUFACTURER/MODEL# QUANTITY VOLTAGE CURRENT <br /> • ALL CONDUIT SHALL BE EMT 3/4"IN DIAMETER UNLESS OTHERWISE STATED. UTILITY PROVIDER: SNOPUD <br /> MAIN SERVICE VOLTAGE: 240V UTILITY FEED+SOLAR BACKFEED ENPHASE IQ8PLUS-72-2-US 18 240 VAC 1.21A <br /> SYSTEM SIZE:-18 x 400W=7.200 kWDC MAIN PANEL BRAND: EATON 200A+30A=230A <br /> 18 x 290VA=5.220 kWAC MAIN SERVICE PANEL: (E)200A MAIN CIRCUIT BREAKER RATING: (E)200A BUSS RATING x 120% NOTE:THE AC DISCONNECT IS LOCATED <br /> MAIN SERVICE LOCATION: SOUTH 2O0A x 120%=240A WITHIN 10FT OF UTILITY METER <br /> NOTE: SERVICE FEED SOURCE: OVERHEAD <br /> 3/4" OR GREATER EMT CONDUIT <br /> AC DISCONNECT SHALL BE LOCATED <br /> RUN (7/8"ABOVE ROOF SURFACE) WITHIN 10'OF UTILITY METER BI-DIRECTIONAL <br /> UTILITY METER VERSION <br /> 1-PHASE,3-W, DESCRIPTION DATE REV <br /> 120V/24OV,60Hz INITIAL RELEASE 06/20/2023 UR <br /> (N)ENPHASE IQ <br /> 09 MICRO-INVERTERS IN BRANCH#1 COMBINER BOX 4 <br /> X2-IQ-AM 1-240-4 <br /> (IEEE1547:2018)[240V] <br /> • • • LILI <br /> L � f <br /> ti ti ti 10A/15A (N)AC DISCONNECT 30A <br /> NON-FUSED,VISIBLE <br /> — (N)JUNCTION BOX LOCKABLE LABELED <br /> DISCONNECT,240 VAC SER(E)MAIN <br /> 09 MICRO-INVERTERS IN BRANCH#2 L1 L1 ICE PANEL, <br /> 20A 20OAE{ 200AVRATED, <br /> 120/240V <br /> m <br /> L L2JB <br /> 20A (E)MAIN BREAKER PROJECT NAME <br /> • • • L1 L1 200A/2P,240V <br /> L1 L1 L2 L2 T <br /> L L2M IQ GATEWAY N N Q LID <br /> m <br /> ti ti ti G 30A/2P z W � � <br /> — — — — — — — J BR AKER PV Q LLJ j LJJ � <br /> L — G I BREAKER <br /> (18)ENPHASE IQ8PLUS-72-2-US `Q Q 00 OO O <br /> MICRO INVERTERS(240V) <br /> (LOCATED UNDER EACH PANEL) C co W <br /> EXISTING z = Q co Z � LU <br /> BRANCH TERMINATOR Q-TERM A GROUNDING > Q 03 <br /> FOR IQ SERIES(TYP.) = SYSTEM > O <br /> W N ~ o ~ ~ z <br /> ~ w * JU <br /> z ~ � U <br /> Q > Qom = LLJ <br /> Wire Tag Conduit Wire Qty <br /> Wire Temp. Wire Temp. Conduit Derated Inverter NEC Design Ground Ground Wire LU 0 <br /> Gauge Wire Type Rating Ampacity(A) Derate Fill Derate Ampacity(A) Qty NOC(A) Correction Current(A) Size Type <br /> A OPEN AIR 2 12 AWG Q Cable 90°C 30 1.00 N/A 30.00 09 1.21 1.25 13.61 06 AWG BARE CU <br /> B 3/4" EMT 4 12 AWG THWN-2 90°C 30 1.00 0.80 24.00 09 1.21 1.25 13.61 06 AWG THWN-2 SHEET NAME <br /> C 3/4" EMT 3 6 AWG THWN 75°C 65 1.00 1.0 65.00 18 1.21 1.25 27.23 06 AWG THWN ELECTRICAL LINE <br /> DIAGRAM & <br /> CALCULATION <br /> SHEET SIZE <br /> ANSI B <br /> 11" X 17" <br /> 1 ELECTRICAL LINE DIAGRAM WITH CALCULATION SHEET NUMBER <br /> SCALE: NTS PV-4 <br />