My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
515 72ND ST SE 2023 2026-01-06
>
Address Records
>
72ND ST SE
>
515
>
515 72ND ST SE 2023 2026-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 3:58:49 PM
Creation date
8/22/2023 7:29:11 AM
Metadata
Fields
Template:
Address Document
Street Name
72ND ST SE
Street Number
515
Year
2023
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ARCHITECTURAL SPECS <br /> Part 1 — General <br /> 1.1 DESCRIPTION OF PRODUCT <br /> a. The product described herein,manufactured by EZ-ACCESS('manufacturer'),is an aluminum modular ramp consisting <br /> of ramp sections,platforms,rails,and supports that are selected to provide adequate ramping height. <br /> 1.2 QUALITY ASSURANCE <br /> a. The ramp may be subject to state,local,and city approval prior to installation and subject to inspection after <br /> installation. <br /> 1.3 REFERENCE CODES <br /> a. Americans With Disabilities Act Handbook(published by the Equal Employment Opportunity Commission and the U.S. <br /> Department of Justice,publication EEOC-BK-19). <br /> 1.4 SUBMITTALS <br /> a. Shop drawings by contractor or manufacturer's literature for approval.Drawings shall indicate layout,unit locations, <br /> unit identification,connections details,support items,and dimensions. <br /> b. A sample of the ramp treads showing slip resistant ramp surfaces. <br /> 1.5 DELIVERY AND HANDLING <br /> a. The contractor shall inspect the components upon delivery to ensure that the proper materials have been received <br /> and are not damaged or defective. Damaged or defective materials shall be removed from the site. <br /> 1.6 FIELD MEASUREMENTS <br /> a. Verify that field measurements are as indicated on the placement of plans. <br /> 1.7 WARRANTY—LIMITED LIFETIME <br /> a. The manufacturer shall have in writing a limited lifetime warranty against any defect in materials and workmanship. <br /> Part 2 — Overview <br /> 2.1 OVERVIEW <br /> a. All PATHWAY 3G ramps and accessories shall be prefabricated modular units as manufactured by EZ-ACCESS.These <br /> ramps shall be modular in design to allow for easy of assembly and relocation. <br /> 2.2 RAMPS <br /> a. ENGINEERING <br /> 1. Ramp sections shall be designed to 2018 International Residential Code(IRC)with a minimum uniform live load <br /> of 40 lbs.per square foot(PSF)and a concentrated vertical load of 300 lbs. <br /> b. MATERIALS <br /> 1. Ramp sections shall be constructed using 6000 series aluminum alloy with 6061-T6 or 6005-T5 used for <br /> structural components. <br /> 2. All structural fasteners which attach ramps together and handrails to ramps shall be of grade 5 strength or higher <br /> and shall be zinc plated or zinc chromate finish. <br /> c. DESIGN AND FABRICATION <br /> 1. PATHWAY 3G ramp units are to be built to shape,size,and finish as indicated on approved drawings. <br /> 2. Ramp surface is to be continuous,that is no gaps greater than%", and shall have an extruded slip resistant <br /> surface. Platform deck surface will be knurled to make slip resistance bi-directional. <br /> 3. Ramps shall be constructed of either interlocking 1.125"x 6"treads welded to side rails, or.5"-.125" <br /> standard expanded metal (EM)welded to a tubular support frame which connects side rails. <br /> 4. All ramp sections shall have a 2" minimum curb height. <br /> 5. Top of all ramps must accept a full width pivoting top adapter plate with a minimum 3" extension with a <br /> preformed angle between 8°and 12°with a slip resistant surface. <br /> 6. Bottom of all ramps must accept a full width pivoting bevel with a slip resistant surface from ramp to <br /> ground transition. <br /> 7. All fasteners shall be captured either on outside of ramp or underneath. <br /> 8. There shall be no fasteners protruding into the inner usable ramp or curb surface. <br /> 2.3 PLATFORMS <br /> a. ENGINEERING <br /> 1. Platforms sections shall be designed to 2018 International Residential Code(IRC) with a minimum uniform <br /> live load of 40 lbs. per square foot(PSF) and a concentrated vertical load of 300 lbs. <br /> b. MATERIALS <br /> 1. Platform sections shall be constructed using 6000 series aluminum alloy with 6061-T6 or 6005-T5 used for <br /> structural components. <br /> c. DESIGN AND FABRICATION <br /> 1. Platform units are to be built to shape,size,and finish as indicated on approved drawings. <br /> 2. Platform surface is to be continuous,that is no gaps greater than %", and shall have an extruded slip <br /> resistant surface, knurled to make slip resistance bi-directional. <br />