My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
515 72ND ST SE 2023 2026-01-06
>
Address Records
>
72ND ST SE
>
515
>
515 72ND ST SE 2023 2026-01-06
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/6/2026 3:58:49 PM
Creation date
8/22/2023 7:29:11 AM
Metadata
Fields
Template:
Address Document
Street Name
72ND ST SE
Street Number
515
Year
2023
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
43
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECTION 5 MUST BE COMPLETED BY THE BUILDING DEPARTMENT IN THE JURISDICTION THE HOME WILL BE LOCATED. <br /> PLEASE CHECK ALL APPLICABLE BOXES; MATCH THE LIST BELOW TO THE APPLICANT'S FLOOR PLAN—USING THEIR PROSPECTIVE <br /> RESIDENT BEDROOM DESIGNATIONS OF A 8 C D E AND FAN CLASSIFICATION CODES, NS1 OR NS2. <br /> SECTION • ' INSPECTION <br /> R330.3 Sleeping Room Classification: Each sleeping room in an Adult family Home shall be classified as: <br /> Type S—where the means of egress contains stairs, elevators or platform lifts to evacuate residents to public area. <br /> Type NS1—where 1 means of egress at grade level (has no stairs)or ramp constructed compliant with R330.9 is provided to evacuate <br /> residents to public area. <br /> Type NS2—where 2 means of egress at grade level (both have no stairs)or ramps constructed compliant with R330.9 are provided to <br /> evacuate residents to public area. <br /> SLEEPING ROOM A 0 Type S 0 Type N51 0 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No 1 [3N/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM B 113 Type S 113 Type NS1 0 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No I ON/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM C 10 Type S 10 Type NS1 10 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside JE3 Yes 0 No 1 [3N/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM D 10Type S 10Type NS1 [3 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside 0 Yes 0 No 1 [3N/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF (minimum dimensions at least 24"high; at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM E 10Type S 10Type NSI 13 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside JE3 Yes 0 No 1 [3N/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> SLEEPING ROOM F 10 Type S 10 Type NS1 0 Type NS2 YES NO <br /> Closet door/s are readily openable from the inside0e0 No 1 [3N/A I Smoke alarm is installed in the bedroom 0 0 <br /> Bedroom door opens easily and quickly from the outside when locked 0 0 <br /> Sleeping room window has a net opening of 5.7 SF(minimum dimensions at least 24"high;at least 20"wide) 0 0 <br /> EXCEPT per R310.2.1:at-grade escape windows—may have net clearance opening 5 SF <br /> Sleeping room window has a maximum sill height of 44"above floor to clear opening; no steps under window allowed 0 0 <br /> Implementation Date: 2021 February 01 <br /> Updated: 2021 February <br />
The URL can be used to link to this page
Your browser does not support the video tag.