Laserfiche WebLink
Permit#: FA2306-013 <br /> Site Address: 1415 75th St SW <br /> Applicant: Jules Mayer <br /> Application Date:06/08/202304 <br /> Description: Helion Energy Control Room Q LL Q <br /> v L O LL <br /> Review Status: 1st Review by City&Peer Reviewers <br /> Review Date: 06/12/2023 <br /> r <br /> EVERETT '-4"ti�►"tib' <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 06/12/2023 10:50:02 <br /> HELION ENERGY CNTRL R1. AM <br /> Y U <br /> U � <br /> r <br /> M <br /> FIRE ALARM SYSTEM OPERATIONAL MATRIX GENERAL NOTES <br /> N <br /> ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1.FACTORY RECOMMENDED MINIMUM WIRING SIZES,TYPE AND 7.PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE Q <br /> CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY CIRCUITS SHALL NOT BE PERMITTED. o <br /> FOLLOWED.ANYONE WILLING TO MAKE CHANGES WILL DO SO AT <br /> O 1"SSO THEIR OWN RISM 8.PARALLEL BRANCHING OF WIRE TO ADDRESSABLE INITIATING DEVICE <br /> CIRCUITS IS PERMISSIBLE. w <br /> 2.THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN z w <br /> DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND 9.PER NFPA 72,SECTION 29.8.3.4(7):SMOKE ALARMS AND SMOKE U <br /> QO 0 4i4 ��w SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND DETECTORS SHALL NOT BE INSTALLED WITHIN A 361N.(910MM) ( �I <br /> OQ {U5 G 5� 5 BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR > o <br /> � <br /> �S l�ti �G�S4 PG4�S1�44 y� OBSTRUCTIONS.THE WIRING OR CIRCUIT COUNTS(IF SHOWN)ARE HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF <br /> PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN THE DIRECT AIRFLOW FROM THOSE REGISTERS. o <br /> INSTALLATION OR TO DETERMINE WIRING ROUTES. <br /> 10.SMOKE ALARMS AND CO-DETECTION WILL BE INSTALLED BY <br /> 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS ELECTRICAL CONTRACTOR. <br /> LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE o <br /> 4 P P 4v4v4v 4�4�4� <br /> PERMITTED. 11.THE AUDIBLE ALARM NOTIFICATION APPLIANCES SHALL PROVIDE A <br /> CAUSE Q�Q� �¢�¢�¢O y�y�y�4 �.��.�y�$ REMARKS SOUND PRESSURE LEVEL OF I5 DECIBELS(dBA)ABOVE THE AVERAGE <br /> 4.PER NFPA 72,SECTION 17.7.1.11.3:WHERE DETECTION IS NOT AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL <br /> SMOKE HEAT DETECTORS • • • • • REQUIRED DURING CONSTRUCTION,DETECTORS SHALL NOT BE HAVING A DURATION OF NOT LESS THAN 60 SECONDS,WHICHEVER IS <br /> MANUAL PULL STATION • • • • • INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE GREATER,IN EVERY OCCUPIABLE SPACE WITHIN THE BUILDING.IN zo <br /> SYSTEM RESET • COMPLETED CLEANUP. COMPLIANCE WITH CURRENT IFC AND NFPA 72 CODES. r N N <br /> SIGNAL SILENCE • • x o o <br /> AC POWER FAILURE • • • 5.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE <br /> LATEST UL,NEC.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS <br /> FIRE ALARM TROUBLE(OPEN, APPLICABLE TO THE CITY STANDARDS. Z o <br /> SHORTS,OR GROUNDS)ON • • • w �w 5 5 S <br /> INITIATION OR SIGNALING CIRCUITS 6.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, <br /> TAMPER SWITCHES • • • FACTORY AVAILABILITY,ETC.WE RESERVE THE RIGHT TO SUBSTITUTE z_ <br /> WATERFLOW SWITCH • • • 10101 EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENT OF - <br /> EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. 3 <br /> 3 P ° n <br /> Q 1��o� C, <<o SCOPE OF WORK: U <br /> 30 30 EX o <br /> EX <br /> 30 15 -RELOCATE EX DEVICE IN CONTROL ROOM TO NEW <br /> EX EX ACT CEILING <br /> 30 15 <br /> EX EX <br /> FIRE ALARM DEVICE LEGEND <br /> 30 30 <br /> EX EX SYMBOL QTY DESCRIPTION MODELNUMBER MANUFACTURER BACKBOX MOUNTING HEIGHT G Z <br /> 30 EX 15 AC EX FIRE ALARM CONTROL PANEL 5808 SILENT KNIGHT EX EX O J <br /> G�L�o EX CP EX FIRE CONTROL POWER SUPPLY HPFF8 HONEYWELL MOUNT ON WALL TOP 72"AFF d <br /> J cc <br /> 95 '#2 30 30 au EX HORN STROBE-CEILING MOUNT PC2RL SYSTEM SENSOR 4S BOX CEILING O W <br /> EX � EX EX` au EX STROBE-CEILING MOUNT SCRL SYSTEM SENSOR 4SBOX CEILING H U) <br /> 95 EX 30 EX 30 EX 30 EX ❑W EX WATERFLOW SWITCHES SKMONITOR SILENT KNIGHT EX EX O ccN <br /> ©M EX CONTROL MODULE SKCONTROL SILENT KNIGHT 4S BOX VERIFY IN FIELD V co) Z <br /> 95 30 30 30 W <br /> EX EX EX EX ® EX PHOTO SMOKE SKPHOTOW SILENT KNIGHT 4S BOX W/SG MUDRING CEILING >- W <br /> ¢ COrn a <br /> 30 15 30 30 C H <br /> EX EX EX EX Z fA j <br /> 30 15 30 30 W Q <br /> EX EX EX EX O fZ W Q <br /> 3cc <br /> 0Ln LU <br /> EX 30 EX 30 EX 30 EX JW Ir <br /> s LU <br /> k 30 30 15 30 2 2 r W LL <br /> C4o<�>' EX EX EX EX \ <br /> 30 95 15 15 30 <br /> EX EX EX EX EX TECTAerospaceQ <br /> 141575th St SW, r� <br /> 30 95 30 30 30 <br /> EX EX EX EX EX •Everett,WA98203 <br /> R <br /> 15 15 30 EX 30 95 Ke si ht Technologies i <br /> EX EX EX 3 y 9 9 Aramerk JULES MAYER,SET ty 0 0_ u <br /> EX QUniform S NICET 4130993 r 1 Q_ m 4 <br /> 15 30 30 30 95 odmHY V - o s <br /> FIRE ALARM SYSTEMS.LEVEL IV <br /> EX EX EX EX EX <br /> A A A A A ' ss <br /> A FCPS 41 A 4-a <br /> HOHIPPS LL m9 Hv <br /> FACP FIRE ALARMPo <br /> WER <br /> SILENT KNIGHT B B A SUPPLY V T �y <br /> I\ tt W ISI <br /> FIRE ALARM <br /> CONTROL CM NAC CIRCUIT)T T O 751hsSw 75ms<sw rss <br /> 75th ^ 3 <br /> PANEL ?EX EX J/ <br /> NAC# Q <br /> t Alpine Cleaning Axiom Divisla <br /> THE CIRCUIT ROUTING AND WIRING COUNTS ON THE <br /> 120 VAC FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC <br /> BASED ON CONTINUOUS AND SHORTEST POSSIBLE <br /> 20 AMP DEDICATED CIRCUIT BBASEROUTING FROM THE CONTROL PANEL AND BETWEEN <br /> VICINITY MAP CONNECTED FIELD DEVICES WITH ND PHYSICAL <br /> FIRE ALARM RISER OBSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS <br /> QF SHOWN) ARE PROVIDED AS A CONVENIENCE <br /> ONLY AND AS MEANS TO HASTEN INSTALLATION <br /> OR TC DETERMINE WIRING ROUTS. ALL FIRE ALARM <br /> WIRING CAN BE RAN IN SAME CONDUIT. <br />