My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1415 75TH ST SW HELION ENERGY 2023-08-24
>
Address Records
>
75TH ST SW
>
1415
>
HELION ENERGY
>
1415 75TH ST SW HELION ENERGY 2023-08-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2023 11:58:52 AM
Creation date
8/22/2023 1:22:03 PM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SW
Street Number
1415
Tenant Name
HELION ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
20
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Permit#: FA2306-013 <br /> Site Address: 1415 75th St SW <br /> Applicant: Jules Mayer <br /> Application Date:06/08/202304 <br /> Description: Helion Energy Control Room Q LL Q <br /> v L O LL <br /> Review Status: 1st Review by City&Peer Reviewers <br /> Review Date: 06/12/2023 <br /> r <br /> EVERETT '-4"ti�►"tib' <br /> Everett Fire Dept.Permit Review <br /> Status:Approved <br /> Reviewed By:KBrown <br /> 06/12/2023 10:50:02 <br /> HELION ENERGY CNTRL R1. AM <br /> Y U <br /> U � <br /> r <br /> M <br /> FIRE ALARM SYSTEM OPERATIONAL MATRIX GENERAL NOTES <br /> N <br /> ALARM TROUBLE SUPERVISORY MISCELLANEOUS 1.FACTORY RECOMMENDED MINIMUM WIRING SIZES,TYPE AND 7.PARALLEL BRANCHING OF WIRE TO ALL NOTIFICATION APPLIANCE Q <br /> CONSTRUCTION AS NOTED ON THE DRAWINGS MUST BE STRICTLY CIRCUITS SHALL NOT BE PERMITTED. o <br /> FOLLOWED.ANYONE WILLING TO MAKE CHANGES WILL DO SO AT <br /> O 1"SSO THEIR OWN RISM 8.PARALLEL BRANCHING OF WIRE TO ADDRESSABLE INITIATING DEVICE <br /> CIRCUITS IS PERMISSIBLE. w <br /> 2.THE CIRCUIT ROUTING AND WIRING COUNTS ON THE FLOOR PLAN z w <br /> DRAWINGS ARE SHOWN DIAGRAMMATIC BASED ON CONTINUOUS AND 9.PER NFPA 72,SECTION 29.8.3.4(7):SMOKE ALARMS AND SMOKE U <br /> QO 0 4i4 ��w SHORTEST POSSIBLE ROUTING FROM THE CONTROL PANEL AND DETECTORS SHALL NOT BE INSTALLED WITHIN A 361N.(910MM) ( �I <br /> OQ {U5 G 5� 5 BETWEEN CONNECTED FIELD DEVICES WITH NO PHYSICAL HORIZONTAL PATH FROM THE SUPPLY REGISTERS OF A FORCED AIR > o <br /> � <br /> �S l�ti �G�S4 PG4�S1�44 y� OBSTRUCTIONS.THE WIRING OR CIRCUIT COUNTS(IF SHOWN)ARE HEATING OR COOLING SYSTEM AND SHALL BE INSTALLED OUTSIDE OF <br /> PROVIDED AS A CONVENIENCE ONLY AND AS MEANS TO HASTEN THE DIRECT AIRFLOW FROM THOSE REGISTERS. o <br /> INSTALLATION OR TO DETERMINE WIRING ROUTES. <br /> 10.SMOKE ALARMS AND CO-DETECTION WILL BE INSTALLED BY <br /> 3.WIRE SHOWN IN THIS DRAWING SET IS PERMITTED IN RACEWAYS ELECTRICAL CONTRACTOR. <br /> LEADING TO FIRE PROTECTION EQUIPMENT.OTHER WIRE SHALL NOT BE o <br /> 4 P P 4v4v4v 4�4�4� <br /> PERMITTED. 11.THE AUDIBLE ALARM NOTIFICATION APPLIANCES SHALL PROVIDE A <br /> CAUSE Q�Q� �¢�¢�¢O y�y�y�4 �.��.�y�$ REMARKS SOUND PRESSURE LEVEL OF I5 DECIBELS(dBA)ABOVE THE AVERAGE <br /> 4.PER NFPA 72,SECTION 17.7.1.11.3:WHERE DETECTION IS NOT AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL <br /> SMOKE HEAT DETECTORS • • • • • REQUIRED DURING CONSTRUCTION,DETECTORS SHALL NOT BE HAVING A DURATION OF NOT LESS THAN 60 SECONDS,WHICHEVER IS <br /> MANUAL PULL STATION • • • • • INSTALLED UNTIL AFTER ALL OTHER CONSTRUCTION TRADES HAVE GREATER,IN EVERY OCCUPIABLE SPACE WITHIN THE BUILDING.IN zo <br /> SYSTEM RESET • COMPLETED CLEANUP. COMPLIANCE WITH CURRENT IFC AND NFPA 72 CODES. r N N <br /> SIGNAL SILENCE • • x o o <br /> AC POWER FAILURE • • • 5.FIRE ALARM SYSTEM INSTALLATION SHALL CONFORM WITH THE <br /> LATEST UL,NEC.,N.F.P.A.,W.A.C.,AND OTHER STANDARDS AS <br /> FIRE ALARM TROUBLE(OPEN, APPLICABLE TO THE CITY STANDARDS. Z o <br /> SHORTS,OR GROUNDS)ON • • • w �w 5 5 S <br /> INITIATION OR SIGNALING CIRCUITS 6.WHEN NECESSARY,DUE TO CHANGING DESIGN REQUIREMENTS, <br /> TAMPER SWITCHES • • • FACTORY AVAILABILITY,ETC.WE RESERVE THE RIGHT TO SUBSTITUTE z_ <br /> WATERFLOW SWITCH • • • 10101 EQUIPMENT HEREIN MENTIONED OR SPECIFIED,WITH EQUIPMENT OF - <br /> EQUAL OR BETTER QUALITY,FUNCTION AND DESIGN. 3 <br /> 3 P ° n <br /> Q 1��o� C, <<o SCOPE OF WORK: U <br /> 30 30 EX o <br /> EX <br /> 30 15 -RELOCATE EX DEVICE IN CONTROL ROOM TO NEW <br /> EX EX ACT CEILING <br /> 30 15 <br /> EX EX <br /> FIRE ALARM DEVICE LEGEND <br /> 30 30 <br /> EX EX SYMBOL QTY DESCRIPTION MODELNUMBER MANUFACTURER BACKBOX MOUNTING HEIGHT G Z <br /> 30 EX 15 AC EX FIRE ALARM CONTROL PANEL 5808 SILENT KNIGHT EX EX O J <br /> G�L�o EX CP EX FIRE CONTROL POWER SUPPLY HPFF8 HONEYWELL MOUNT ON WALL TOP 72"AFF d <br /> J cc <br /> 95 '#2 30 30 au EX HORN STROBE-CEILING MOUNT PC2RL SYSTEM SENSOR 4S BOX CEILING O W <br /> EX � EX EX` au EX STROBE-CEILING MOUNT SCRL SYSTEM SENSOR 4SBOX CEILING H U) <br /> 95 EX 30 EX 30 EX 30 EX ❑W EX WATERFLOW SWITCHES SKMONITOR SILENT KNIGHT EX EX O ccN <br /> ©M EX CONTROL MODULE SKCONTROL SILENT KNIGHT 4S BOX VERIFY IN FIELD V co) Z <br /> 95 30 30 30 W <br /> EX EX EX EX ® EX PHOTO SMOKE SKPHOTOW SILENT KNIGHT 4S BOX W/SG MUDRING CEILING >- W <br /> ¢ COrn a <br /> 30 15 30 30 C H <br /> EX EX EX EX Z fA j <br /> 30 15 30 30 W Q <br /> EX EX EX EX O fZ W Q <br /> 3cc <br /> 0Ln LU <br /> EX 30 EX 30 EX 30 EX JW Ir <br /> s LU <br /> k 30 30 15 30 2 2 r W LL <br /> C4o<�>' EX EX EX EX \ <br /> 30 95 15 15 30 <br /> EX EX EX EX EX TECTAerospaceQ <br /> 141575th St SW, r� <br /> 30 95 30 30 30 <br /> EX EX EX EX EX •Everett,WA98203 <br /> R <br /> 15 15 30 EX 30 95 Ke si ht Technologies i <br /> EX EX EX 3 y 9 9 Aramerk JULES MAYER,SET ty 0 0_ u <br /> EX QUniform S NICET 4130993 r 1 Q_ m 4 <br /> 15 30 30 30 95 odmHY V - o s <br /> FIRE ALARM SYSTEMS.LEVEL IV <br /> EX EX EX EX EX <br /> A A A A A ' ss <br /> A FCPS 41 A 4-a <br /> HOHIPPS LL m9 Hv <br /> FACP FIRE ALARMPo <br /> WER <br /> SILENT KNIGHT B B A SUPPLY V T �y <br /> I\ tt W ISI <br /> FIRE ALARM <br /> CONTROL CM NAC CIRCUIT)T T O 751hsSw 75ms<sw rss <br /> 75th ^ 3 <br /> PANEL ?EX EX J/ <br /> NAC# Q <br /> t Alpine Cleaning Axiom Divisla <br /> THE CIRCUIT ROUTING AND WIRING COUNTS ON THE <br /> 120 VAC FLOOR PLAN DRAWINGS ARE SHOWN DIAGRAMMATIC <br /> BASED ON CONTINUOUS AND SHORTEST POSSIBLE <br /> 20 AMP DEDICATED CIRCUIT BBASEROUTING FROM THE CONTROL PANEL AND BETWEEN <br /> VICINITY MAP CONNECTED FIELD DEVICES WITH ND PHYSICAL <br /> FIRE ALARM RISER OBSTRUCTIONS. THE WIRING OR CIRCUIT COUNTS <br /> QF SHOWN) ARE PROVIDED AS A CONVENIENCE <br /> ONLY AND AS MEANS TO HASTEN INSTALLATION <br /> OR TC DETERMINE WIRING ROUTS. ALL FIRE ALARM <br /> WIRING CAN BE RAN IN SAME CONDUIT. <br />
The URL can be used to link to this page
Your browser does not support the video tag.