■=A&RScope <br />ni n n n <br />0 <br />0 Equipment Schedule <br />Ref. <br />Category <br />Equipment <br />QTY <br />1 <br />Modules <br />REC405AA Pure <br />25 <br />2 <br />Optimizers <br />S440 SolarEdge Optimizer <br />25 <br />3 <br />Jbox <br />JBox <br />2 <br />4 <br />Inverters <br />Solar Edge SE100001-1 <br />1 <br />5 <br />Disconnect <br />60A 240V 2 Pole I Heavy Duty, Fuse, Lockable <br />1 <br />DisconnectFuse <br />FLNR - 60 A Fuses for Disconnect (qty 1 /pole) <br />2 <br />Monitoring <br />SolarEdge PV Inverter Monitoring <br />1 <br />ElectricalWork <br />Generator outlet, breaker, &mechanical interlock kit <br />1 <br />0 Conductor Schedule <br />= Existing or <br />Others Scope <br />Supply Side Connection <br />705.11 <br />xisting) <br />Sin Service Panel <br />ph 240V Service) <br />Sin Breaker: 200A <br />is Rating:200A <br />lew) Mechanical Interlock <br />L <br />nverter Specs <br />Watts <br />output <br />AC <br />Voltage <br />##of <br />Inverters <br />oPD <br />Solar Edge SE10000H <br />10000 <br />42 <br />240 <br />1 <br />60 <br />****N/A**** <br />0 <br />0 <br />0 <br />0 <br />0 <br />****N/A**** <br />0 <br />0 <br />0 <br />0 <br />0 <br />Module Specs <br />Watt <br />I <br />V <br />Voc <br />I c <br />E 40 AA Pure <br />405 <br />9.56 <br />42.4 <br />48.9 <br />10.14 <br />Femp. Adjusted <br />0 <br />0 <br />38.7 <br />52.7 <br />0 <br />Summary <br />Distance <br />(ft) <br />Current <br />@125% <br />Operating <br />Voltage <br />Voltage <br />Drop <br />V. Drop <br />(total) <br />A <br />(2)#10 CU, (1)#6 EGC, PV Wire 600V, AIR <br />50 <br />18.75A <br />400V <br />0.28% <br />0.91% <br />B <br />(6)#10 CU, (1)#10 EGC, THWN-2, 0.75"EMT(min) <br />50 <br />18.75A <br />400V <br />0.28% <br />C <br />(2)#6 CU, (1)#8 N, (1)#10 EGC, THWN-2, 0.75"EMT(min) <br />10 <br />52.5A <br />240V <br />0.17% <br />D <br />(2)#6 CU, (1)#6 N, THWN-2, 1"PVC(min) <br />10 <br />52.5A <br />240V <br />0.17% <br />General Notes: <br />Utility: SnoPUD <br />1. EGC Where exposed to physical damage will be #6AWG <br />Bare CU <br />2. If installing conduit on the roof, maintain greater than 7/8" <br />above the surface <br />3. NEC 690.12: Rapid Shutdown initiated by loss of Grid or AC <br />Disconnect <br />4. For supply side taps, a #6 GEC (min.) will be run separately <br />from the disconnect and connected to the grounding electrode <br />with an irreversible crimp <br />A&RSOLAR <br />3211 Martin Luther King Jr Way S. <br />Seattle, WA 98144 (206)707-9937 <br />THIS DRAWING CONSTITUTES THE <br />CONFIDENTIAL INFORMATION OF A&R SOLAR <br />AND ITS RECEPTOR. POSSESSION DOES NOT <br />CONFER ANY RIGHT IN OR LICENSE TO USE IT <br />OR THE INFORMATION DISCLOSED HEREIN <br />NOR ANY RIGHT TO REPRODUCE THIS <br />DRAWING OR ANY PART HEREIN WITHOUT <br />THE WRITTEN CONSENT OF A&R SOLAR. <br />U <br /><1 <br />L <br />U <br />(1) <br />M <br />r <br />p <br />� <br />p <br />� <br />O <br />W <br />c) <br />00 <br />O <br />ap <br />411- <br />!S2 <br />< <br />!�e <br />U <br />N <br />2: <br />U <br />C)!l <br />-0 <br />C: <br />klo <br />4-) <br />W <br />ro <br />c) <br />, <br />0 <br />NNO <br />(1) <br />��� <br />WaLn <br />� <br />o <br />� <br />o <br />REVISIONS <br />Rev. #: I Date: <br />I Designed by: Thomas N � <br />Project Manager: <br />Will MacArthur <br />(206)307-1741 <br />Current Date:Jul 05, 2023 <br />El Single Line <br />