NOTES <br />1. UTILITY SHALL BE NOTIFIED BEFORE ACTIVATION OF PV SYSTEM <br />2. REMOVAL OF UTILITY -INTERACTIVE INVERTER OR OTHER EQUIPMENT SHALL NOT <br />DISCONNECT THE BUILDING CONNECTION BETWEEN THE GROUNDING ELECTRODE <br />CONDUCTOR AND THE PV SOURCE AND/OR OUTPUT CIRCUIT GROUNDED CONDUCTOR <br />3. ALL PV SYSTEM COMPONENTS SHALL BE LISTED BY A RECOGNIZED TESTING AGENCY <br />4. WIRING MATERIALS SHALL COMPLY WITH MAXIMUM CONTINUOUS CURRENT OUTPUT <br />AT 25' C; WIRE SHALL BE WET RATED AT 90"C <br />S. EXPOSED PHOTOVOLTAIC SYSTEM CONDUCTORS ON THE ROOF WILL BE USE-2 OR PV <br />TYPE WIRE. <br />6. ALL EXTERIOR CONDUIT, FITTINGS, AND BOXES SHALL BE RAIN -TIGHT AND APPROVED <br />FOR USE IN WET LOCATIONS (NEC 314.15) <br />7. ALL METALLIC RACEWAYS AND EQUIPMENT SHALL BE BONDED AND ELECTRICALLY <br />CONTINUOUS (NEC 250.90, 260.96) <br />8. FOR UNGROUNDED SYSTEMS, THE PHOTOVOLTAIC SOURCE AND OUTPUT CIRCUITS <br />SHALL BE PROVIDED WITH A GROUND -FAULT PROTECTION DEVICE OR SYSTEM THAT <br />DETECTS A GROUND FAULT, INDICATES THAT FAULT HAS OCCURED, AND <br />AUTOMATICALLY DISCONNECTS ALL CONDUCTORS OR CAUSES THE INVERTER TO <br />AUTOMATICALLY CEASE SUPPLYING POWER TO OUTPUT CIRCUITS <br />9. ANY REQUIRED GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT <br />FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT <br />10. ALL PV MODULES AND ASSOCIATED EQUIPMENT SHALL BE PROTECTED FROM ANY <br />PHYSICAL DAMAGE <br />11. ALL FIELD -INSTALLED JUNCTION, PULL, AND OUTLET BOXES LOCATED BEHIND <br />MODULES SHALL BE ACCESSIBLE DIRECTLY OR BY DISPLACEMENT OF A MODULE <br />SECURED BY REMOVABLE FASTENERS <br />12. FOR GROUNDED SYSTEMS, THE INVERTER IS EQUIPPED WITH GROUND FAULT <br />PROTECTION AND A GFI FUSE PORT FOR GROUND FAULT INDICATION <br />13. WHEN BACKFED BREAKER IS THE METHOD OF UTILITY INTERCONNECTION, THE <br />BREAKERS SHALL NOT READ "LINE AND LOAD" <br />14. THE INSTALLED SOLAR SYSTEM HAS A DISTRIBUTED WEIGHT OF LESS THAN 4 PSF <br />15. THE CONCENTRATED LOAD FOR EACH VERTICAL SUPPORT IS LESS THAN 45 LBS <br />16. AC DISCONNECT IS A "KNIFE BLADE" TYPE DISCONNECT <br />17. THE WORKING CLEARANCES AROUND THE EXISTING ELECTRICAL EQUIPMENT AS WELL <br />AS THE NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC <br />110.26 <br />18. THE PHOTOVOLTAIC INVERTER WILL BE LISTED AS UL 1741 COMPLIANT <br />19. SMOKE ALARMS AND CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED <br />ONTO THE EXISTING DWELLING. THESE SMOKE ALARMS ARE REQUIRED TO BE IN ALL <br />BEDROOMS, OUTSIDE EACH BEDROOM, AND AT LEAST ONE ON EACH FLOOR OF THE <br />HOUSE. CARBON MONOXIDE ALARMS ARE REQUIRED TO BE RETROFITTED OUTSIDE <br />EACH BEDROOM AND AT LEAST ONE ON EACH FLOOR OF THE HOUSE. THESE ALARMS <br />MAY BE SOLELY BATTERY OPERATED IF THE PHOTOVOLTAIC PROJECT DOES NOT <br />INVOLVE THE REMOVAL OF INTERIOR WALL AND CEILING FINISHES INSIDE THE HOME; <br />OTHERWISE, THE ALARMS MUST BE HARD WIRED AND INTERCONNECTED. <br />20. WHEN APPLYING THE 120% RULE OF NEC 705.12(13)(2), THE SOLAR BREAKER TO BE <br />POSITIONED AT THE OPPOSITE END OF THE BUS FROM THE MAIN BREAKER PER <br />705.12(D)(7) <br />21. PLUMBING AND MECHANICAL VENTS THROUGH THE ROOF SHALL NOT BE COVERED BY <br />SOLAR MODULES - NO BUILDING, PLUMBING, OR MECHANICAL VENTS TO BE COVERED <br />OR OBSTRUCTED <br />INVERTER SPECIFICATIONS <br />MANUFACTURER <br />DSM MCROINVERTER <br />MAXIMUM CONRNOUS OUTPUT POWER <br />60VA <br />NOMINALOUTPUTCURRENT <br />2.70A <br />NOMINALACVOLTAGE <br />240 VOLTS <br />NOMNALVOLTAGE RANGE <br />211VWIV <br />NOMINAL FREQUENCY <br />593-60.5 HZ <br />POWER FACTOR <br /><0.99 <br />MAX AC OUTPUT CURRENT <br />16.20A <br />PV MODULE RATING na. STC <br />MANUFACTURER <br />BLUESUN BSM370M0HPH365W <br />MAX POWER-POINTCURREOT(IM') <br />10.56AMPS <br />AWL PONERPOINTVOLTAGE(VMP) <br />34.6 VOLTS <br />OPEN CIRCUIT VOLTAGE(VOC) <br />40.9 VOLTS <br />SHORT CIRCUIT CURRENT QSC) <br />11.20AM'S <br />NOM MAX. PQ,YER AT STC(PMA)C) <br />365 WATT <br />MAX SYSTEM VOLTAGE <br />1500V <br />VWTEbPERATURECOEFRCIENT <br />-0Lm6 C <br />J1-1E <br />REVISIONS <br />o�y�, D.. B:, <br />k:bo«gn 7mrzon w <br />V...w NUM)n A <br />PqW N.. B <br />Adhew <br />w <br />U <br />Z <br />w F_ <br />w w c*3 <br />d > rn <br />} w <br />Z <br />Dip O <br />w W_ z <br />> N <br />O 2 Q <br />Z 00 <br />0 v <br />Q <br />Sheet Name <br />NOTES <br />Sheet Size <br />ANSI B <br />IVX17' <br />Sheet Number <br />E1.2 <br />00 BY <br />
The URL can be used to link to this page
Your browser does not support the video tag.