Laserfiche WebLink
Data Shea <br />Enphase Networking <br />IQ Combiner 4/4C <br />ENPHASE <br />X-IQ-AM1-240-4C . <br />X2-IQ-AM1-240-4C (IE <br />X-IQ-AMl-240-4 <br />X2-IQ-AM1-240-4 (IEEE 1547:2018) <br />u� <br />LISTED <br />To learn more about Enphase offerings, visit enphase,com <br />I Q-C-4-4C-DS- 0103-EN-U S-12-29-2022 <br />The IQ Combiner 414C with IQ Gateway and <br />integrated LTE-M1 cell modem (included <br />only with IQ Combiner 4C) consolidates <br />interconnection equipment into a single <br />enclosure. It streamlines IQ Microinverters and <br />storage installations by providing a consistent, <br />pre -wired solution for residential applications. <br />It offers up to four 2-pole input circuits and <br />Eaton BR series busbar assembly. <br />Smart <br />• Includes IQ Gateway for communication and control <br />• Includes Mobile Connect cellular modem <br />(CELLMODEM-Ml-06-SP-05), included only with <br />IQ Combiner 4C <br />• Includes solar shield to match 'Enphase IQ Battery <br />aesthetics and deflect heat <br />• Supports Wi-Fi, Ethernet, or cellular connectivity <br />• Optional AC receptacle availablefor PLC bridge <br />• Provides production metering and ccnsumplion <br />monitoring <br />Simple <br />• Mounts on single stud with centered brackets <br />• Supports bottom, back and side conduit entry <br />I. • Allows up to four 2-pale branch circuits for 240VAC <br />plug-in breakers (not included) <br />• BOA total PV or storage branch circuits <br />Reliable <br />• durable NRTL-certified NEMA type 3R enclosure <br />• Five-year limited warranty <br />I_ • Two years labor reimbursement program coverage <br />included for both the IQ Combiner SKU's <br />• U'L listed <br />• • X2-IQ-AM1-240-4 and X2-IQ-AM1-240-4C comply with <br />IEEE 1547:2018 (UL 1741-SB, 3'1 Ed.) <br />Lumillo <br />IQ Combiner 414C <br />MODEL NUMBER <br />I Q Co mbi ner 4 <br />IQ Combiner 4 with IQ Gateway printed circuit board for integrated revenue grade PV product ion metering (ANSI C12.20 ± 0.5%) <br />X-IQ-AMl-240-4 <br />and consumption monitoring (±2.5%). Includes a silver solar shield to match the IQ Batteryand IQ System Controller 2 and to <br />X2-IQ-AMI-24D-4 (IEEE 1547:2018) <br />deflect heat. <br />IQ Combiner 4C <br />IQ Combiner4C with IQ Gateway printed circuit board for integ rated revenue grade PV production metering (ANSI C12.20 ± 0.59'°) <br />X-IQ-AM1-240-4C <br />and consumption monitoring (±2.5/). Includes Mobile Connect cellular modem (CELLMODEM-Ml-06-SP-05), a plug -and -play <br />X2-IQ-AMl-24D-4C (IEEE 1547:2018) <br />industrial -grade cell modem for systems upto 60 microinverters. (Available in the US, Canada, Mexico-, Puerto Rico, and the <br />US Virgin Islands, wherethere is adequate cellular service in the installation area.) Includes a silver solar shield to match the <br />IQ Battery and IQ System Controller and to deflect h eat. <br />ACCESSORIES AND REPLACEMENT PARTS (not included, order separately) <br />Supported microinverters IQ6, IQ7, and IQ8. (Do not mix IQ617 Micrvinverters with IQ8) <br />Communications Kit <br />COMM S-CELLMODEM-Ml -06 <br />Includes COMMS-KIT-01 and CELLMODEM-MI-06-SP-05with 5-year Sprint data plan <br />VERSION <br />CELLMODEM-M1-06-SP-05 <br />CELLMODEM-MI-06-AT-05 <br />4G based LTE-MI cellularmodem with 5-year Sprint data plan <br />4Gbased LTE-Ml cellularmodem with 5-yearAT&Tdata plan <br />DESCRIPTION <br />DATE <br />REV <br />INITIAL RELEASE <br />06/15/2023 <br />UR <br />Circuit Breakers Supports Eaton BR210, BR215, 11311220, BR230, BR240, 1311125D, and DR260 circuit breakers. <br />BRK-I DA-2-24OV <br />Circuit breaker, 2 pole, IOA, Eaton BR210 <br />BRK-15A-2-240V <br />Circuit breaker, 2 pole, 15A, Eaton BR215 <br />BRK-20A-2P-240V Circuit breaker, 2 pole, 20A, Eaton BR220 <br />BRK-15A-2P-24OV-B <br />Circuit breaker, 2 pole, 15A, Eaton BR215B with hold down kit support <br />BRK-20A-2P-240V-R <br />Circuit breaker, 2 pole„ 20A, Eaton BR220B with hold down kit support <br />XA-SOLARSHIELD-ES Replacement solar shield for IQ Combiner4/4C <br />XA-PLUG-120-3 <br />Accessory receptacle for Power Line Carrier in IQ Combiner 414C (required for EPLC-01) <br />X-IQ-NA-HD-125A <br />Hold-down kit for Eaton circuit breakerwith screws <br />Consumption monitoring CT <br />A pair of 200A split core current transformers <br />(CT-200-SP LITICT- 20 0-C LAMP) <br />ELECTRICAL SPECIFICATIONS <br />Rating <br />Continuous duty <br />System voltage <br />1201240VAC, 60 Hz <br />Eaton BR series busbar rating <br />125A <br />Max. continuouscurrent rating <br />Max. continuous current rating (input from PV/storage) <br />65A <br />64A <br />PROJECT NAME <br />Max. fuse/circuit rating (output) <br />Branch circuits (solar and/or storage) <br />90A <br />Upto four2-pole Eaton BR series Distributed Generation (DG) breakers only (not included) <br />Q <br />0 <br />Max. total branch circuit breaker rating(input) <br />IQ Gateway breaker <br />Production metering CT <br />RDA of distributed generation/95Awith IQ Gateway breaker included <br />IDA or 15A rating GEISiemens/Eaton included <br />200A solid core pre -installed and wired to lQ Gateway <br />W <br />/ <br />Q <br />7 N <br />L7 LLU <br />W // <br />M ��� <br />W <br />0 <br />� � <br />�n N <br />V (D <br />(� <br />�6�~0 <br />0 <br />a) <br />Q <br />� <br />W <br />w <br />w <br />00 <br />0 U 0 <br />0 w <br />O , <br />O O L <br />� � O M <br />O W� <br />1_ <br />O z 0 <br />O vJ_ Z <br />v <br />< J <br />Q O <br />MECHANICAL DATA <br />Dimensions (wxHxD) 37.5 cm x 49.5 cm x 16.9 cm (14.75 in x 19.5 in x 6.63 in). Height is 53.5 cm (21.06 in) with mounting brackets. <br />Weight 7.5 kg (16.5 Ibs) <br />Ambient temperaturevange -40°O to t46°C (-40°Fto 115°F) <br />Cooling Natural convection, Pius heat shield <br />Enclosure environmental rating Outdoor, NRTL-certified, NEMA type 3R, polycarbonate construction <br />Wire sizes 20Ato 50A breakerinputs: 14 to 4 AWG copper conductors <br />• 60A breaker branch input: 410 1/OAwG copper conductors <br />Main fug combined output 1Oto2/0AWG copper conductors <br />Neutral and ground: 14to 1/0 copper conductors <br />Always follow local Cade requirements for conductor sizing.UJ <br />Altitude Up to 3,000 meters (9,842 feet) <br />INTERNET CONNECTION OPTIONS <br />Integratedwi-Fi IEEE802.11b/g/n <br />Cellular <br />CELLMODEM-M1-46-SP-05, CELLMODEM-MI-06-AT-05 (4G based LTE-MI cellu lar modem). Notethat an Mobile Connect <br />cellular modem is required forall Enphase Energy System installations. <br />Ethernet <br />Optional, IEEE 802.3, Ca15E (orCa16) UTP Ethernet cable (not included) <br />COMPLIANCE <br />SHEET NAME <br />Compliance, IQ Combiner <br />EN 1 H A S E Compliance, IQ Gateway <br />CA Rule 21 (UL 1741-SA) <br />IEEE 1547:2018 - UL 1741-SB, 3,d Ed. (X2-IQ-AM1-240-4 and X2-I0-AM1-240-4c) <br />CAN/CSAC22.2 No. 107.1, Title 47 CFR, Part 15, Class E, ICES 003 <br />Production metering: ANSI C12.20 accuracy class 0.5 (PV production) <br />Consumption metering: accuracy class 2.5 <br />UL 60601-1/CANCSA 22.2 No, 61010-1 <br />0 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 4/4C, and other names are trademarks of <br />Enphase Energy, Inc. Data subject to change. IQ-C-4-4C-D5-0103-EN-US-12-29-2022 <br />SPEC SHEETS <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />SHEET NUMBER <br />PV-8 <br />