AWARNING PHOTOVOLTAIC AC DISC• 4 Lumlo <br /> MAXIMUM AC OPERATING CURRENT:24.20 AMPS <br /> ELECTRICAL SHOCK HAZARD NOMINAL OPERATING AC VOLTAGE: 240 VAC <br /> SOLAR PV SYSTEM EQUIPPED <br /> TERMINALS ON LINE AND LOAD LABEL LOCATION: <br /> SIDES MAY BE ENERGIZED IN AC DISCONNECT(S),PHOTOVOLTAIC SYSTEM POINT OF WITH RAPID SHUTDOWN <br /> THE OPEN POSITION INTERCONNECTION. <br /> PER CODE(S):NEC 2020:690.54 <br /> LABEL LOCATION: PHOTOVOLTAIC POWER SOURCE <br /> INVERTER(S),AC DISCONNECT(S),AC <br /> COMBINER PANEL(IF APPLICABLE). LABEL LOCATION: <br /> PER CODE(S):NEC 2020:NEC 706.15 EMT/CONDUIT RACEWAYS ih TURN RAPID SHUTDOWN <br /> (C)(4)&NEC 690.13(B) (PER CODE:NEC690.31(D)(2) SWITCH TO THE"OFF" SOLAR ELECTRIC <br /> PV PANELS <br /> POSITION TO SHUT DOWN <br /> cis ME= PV SYSTEM AND REDUCE <br /> SHOCK HAZARD IN THE VERSION <br /> PHOTOVOLTAIC LABEL LOCATION: ARRAYDESCRIPTION DATE REV <br /> MAIN SERVICE DISCONNECT/UTILITY METER . INITIAL RELEASE 06/28/2023 LIR <br /> (PER CODE:NEC 690.13(B)) <br /> L_AC DISCONNECT RAPID SHUTDOWN FOR <br /> _ LABEL LOCATION: <br /> LABEL LOCATION: ON OR NO MORE THAT 1 M(3 FT)FROM THE SERVICE DISCONNECTING <br /> AC DISCONNECT L MEANS TO WHICH THE PV SYSTEMS ARE CONNECTED. <br /> NEC 690.13(B) LABEL LOCATION: PER CODE(S):NEC 2020:IFC 690.56(C) <br /> UTILITY SERVICE ENTRANCE/METER,INVERTER/DC <br /> DISCONNECT IF REQUIRED BY LOCAL AHJ,OR <br /> OTHER LOCATIONS AS REQUIRED BY LOCAL AHJ. <br /> PER CODE(S):NEC 2020:690.56(C)(2) <br /> A CAUTION CAUTION ! <br /> WARNING PHOTOVOLTAIC SYSTEM CIRCUIT ISBACKFED MULTIPLE SOURCES OF POWER PROJECT NAME <br /> LABEL LOCATION: Lo <br /> • • • MSP(PER CODE: NEC 705.12(B)&NEC POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE Q T_ <br /> POWER <br /> _ <br /> CONNECTION 690.59 FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN Cn o I-- o <br /> C) I.-_ co <br /> �• NOT • <br /> • _ _ _ AWARNING o > o o o <br /> UQ o oZ:) w 0- <br /> cel o > <br /> LABEL LOCATION: <br /> SERVICE PANEL IF SUM OF BREAKERS EXCEEDS THIS EQUIPMENT FED BY (N) PV MODULES Q m 0 0 LU <br /> PANEL RATING MULTIPLE SOURCES: = Q Q Lo Z W <br /> NEC 705.12(b)(3)(2) TOTAL RATING OF ALL OVERCURRENT > L O <br /> DEVICES EXCLUDING MAIN POWER LU W > ',I- <br /> SUPPLY SHALL NOT EXCEED Q m LL. o <br /> AMPACITY OF BUSBAR < Q Lo o J — z <br /> NOTES AND SPECIFICATIONS: Q N W — U <br /> •SIGNS AND LABELS SHALL MEET THE REQUIREMENTS OF THE D <br /> 2020 ARTICLE 110.21(B),UNLESS SPECIFIC INSTRUCTIONS LABEL LOCATION: J M -LiU <br /> ARE REQUIRED BY SECTION 690,OR IF REQUESTED BY THE POIuj <br /> NTS OF CONNECTION/BREAKER LO w w <br /> LOCAL AHJ. CODE:NEC 705.12(b)(3)(2) 00 <br /> •SIGNS AND LABELS SHALL ADEQUATELY WARN OF HAZARDS ch Lu Q <br /> USING EFFECTIVE WORDS,COLORS AND SYMBOLS. <br /> •LABELS SHALL BE PERMANENTLY THE <br /> EQUIPMENT OR WIRING METHOD ANDIXED SHALLONOT BE HAND A WARNING <br /> WRITTEN. THE DISCONNECTION OF THE <br /> •LABEL SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND GROUNDED CONDUCTOR(S) <br /> THE ENVIRONMENT INVOLVED. MAY RESULT IN OVERVOLTAGE SHEET NAME <br /> •SIGNS AND LABELS SHALL COMPLY WITH ANSI Z535.4-2011, ON THE EQUIPMENT <br /> PRODUCT SAFETY SIGNS AND LABELS,UNLESS OTHERWISE WARNING LABELS & <br /> SPECIFIED. LABEL LOCATION: <br /> •DO NOT COVER EXISTING MANUFACTURER LABELS. COMBINER BOX (N) ENPHASE IQ COMBINER BOX 4 PLACARD <br /> PER CODE:NEC 690.31(E) (N) 60A NON-FUSED AC DISCONNECT SHEET SIZE <br /> (E) UTILITY METER ANSI B <br /> (N) 200A MAIN SERVICE PANEL 11" X 17" <br /> WITH (N) 125A MAIN BREAKER <br /> SHEET NUMBER <br /> PV-5 <br />