BRANOM <br /> Measure.Test.Automate. <br /> Branom Instrument Company <br /> 5610 4th Ave S. <br /> Seattle WA 98108 <br /> United States <br /> Certificate of Calibration#:BIC08688 <br /> Customer Name: Neudorfer Engineers Inc <br /> Address: 5516 1st Ave S Seattle Washington(US)98108 <br /> P O#: SEA-01 <br /> Instrument Description: Fluke 323 <br /> Serial Number: 47643927MV Calibration Date: 01/06/2023 <br /> Customer ID: N/A Calibration Due: 01./06/2024 <br /> Condition Found: In Tolerance Branom Order#: SO-43674 <br /> Condition Left: In Tolerance <br /> Test Procedure Used: BIC-0061 ` <br /> Temperature(°F): 81.0 <br /> Humidity N: 26.2 Issued By: Walter Higdon II <br /> Branom Standards Used: <br /> Asset Asset Serial Number Cal Due Date <br /> Fluke 5500A 1090012 11/21/2023 <br /> Instrument Accuracy: <br /> Electrical Specifications AC Current(Jaw)Range 323........400.0 A 324,325....(40.00,400.0)A Resolution 323........0.1 A 324,325....(0.01,0.1)A Accuracy 323,325....2.0 <br /> %±5 digits(45-65 Hz)2.5%±5 digits(65-400 Hz)324........1.5%±5 digits(45-400 Hz)Note:Add 2%for position sensitivity.DC Current with Jaw(325)Range........... <br /> (40.00,400.0)A Resolution...........(0.01,0.1)A Accuracy...........2.0%±5 digits AC Voltage Range...........600.0 V Resolution...........0.1 V Accuracy(45-400 Hz). <br /> .1.5%±5 digits DC Voltage Range...........600.0 V Resolution...........0.1 V Accuracy...........1%±5 digits Resistance Range 323,324....(400.0,4000)f2 325........ <br /> (400.0,4000,40000)4 Resolution...........(0.1,1,10)0 Accuracy...........1%±5 digits Continuity Beeper 323........-70 0 324/325.....s30 4 Capacitance(324,325) <br /> Range...........(100.0,1000)µF Resolution...........(0.1,1)µF Accuracy...........1%±4 digits Frequency with Jaw(325)Range...........5.0 to 500.0 Hz Resolution..... <br /> ......0.1 Hz Accuracy...........0.5%±4 digits Trigger Level..........5 to 10 Hz,>_10 A 10 to 100 Hz,>_5 A 100 to 500 Hz,>_10 A Specifications Contact Temperature(324,325) <br /> Range..............-10.0°C to 400.0°C Resolution..............0.1°C Accuracy..............1%±8 digits <br /> Calibration Results: <br /> Applied Value Measured Value Lower Limit Higher Limit Unit of Measure Measure/Source Pass/Fail <br /> 10 10.0 9.3 10.7 VAC.50 Hz Measure Pass <br /> 600 599.3 590.5 609.5 VAC.50 Hz Measure Pass <br /> 600 598.8 590.5 609.5 VAC,400 Hz Measure Pass <br /> -600 -599.4 -606.5 -593.5 VDC Measure Pass <br /> 10 10.0 9.4 10.6 VDC Measure Pass <br /> 600 599.7 593.5 606.5 VDC Measure Pass <br /> 10 10.0 9.4 10.6 S2 Measure Pass <br /> 350 350.1 346.0 354.0 S2 Measure Pass <br /> 3500 3500 3460 3540 f2 Measure Pass <br /> 0.12 6.0 5.4 6.6 AAC.50Hz Measure Pass <br /> 0.48 24.2 22.9 25.1 AAC,150Hz Measure Pass <br /> 4.2 210.0 205.3 214.7 AAC,50Hz Measure Pass <br /> Phone:+1206-762-6050 Email:sales@branom.com Web: https://www.branom.com <br /> Thank you for the opportunity to quote your equipment requirements. <br /> Page: 1 / 2 <br /> 17 <br />