STRUCTURAL NOTES <br />DESIGN LOADS <br />ALL DESIGN AND CONSTRUCTION SHALL CONFORM TO THE REQUIREMENTS OF THE <br />INTERNATIONAL BUILDING CODE (IBC) AND INTERNATIONAL EXISTING BUILDING CODE (IEBC), <br />2018 EDITION, AS AMENDED BY THE CITY OF EVERETT. <br />LIVE LOADS <br />IN ADDITION TO THE DEAD LOADS, THE FOLLOWING FLOOR LIVE LOADS WERE USED FOR <br />DESIGN. LIVE LOAD REDUCTION IS PER IBC SECTION 1607.10. <br />REDUCIBLE UNREDUCIBLE <br />STAIRS & CORRIDORS 100 PSF X <br />REFER TO TABLE 1607.1 IN THE IBC FOR RELEVANT CONCENTRATED LIVE LOADS <br />GENERAL NOTES <br />SUBMITTALS <br />SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO ANY FABRICATION OR <br />CONSTRUCTION FOR ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: CONCRETE OR <br />REINFORCEMENT, EMBEDDED STEEL ITEMS, STRUCTURAL STEEL, STEEL DECK, SHEAR STUD <br />LAYOUT, METAL GRATING, AND STAIRS. <br />IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL <br />DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF THE WASHINGTON STATE <br />REGISTERED PROFESSIONAL ENGINEER WHO IS RESPONSIBLE FOR THE DESIGN. <br />INSPECTION <br />SPECIAL INSPECTION PER IBC CHAPTER 17 SHALL BE PERFORMED BY AN APPROVED <br />TESTING AGENCY AS INDICATED IN THE STATEMENT OF SPECIAL INSPECTIONS AND TESTING. <br />SPECIAL CONDITIONS <br />CONTRACTOR SHALL VERIFY ALL LEVELS, DIMENSIONS, AND EXISTING CONDITIONS IN THE <br />FIELD BEFORE PROCEEDING. CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY <br />DISCREPANCIES OR FIELD CHANGES PRIOR TO INSTALLATION OR FABRICATION. IN CASE OF <br />DISCREPANCIES BETWEEN THE EXISTING CONDITIONS AND THE DRAWINGS, THE <br />CONTRACTOR SHALL OBTAIN DIRECTION FROM THE ARCHITECT BEFORE PROCEEDING. <br />DIMENSIONS NOTED AS PLUS OR MINUS (t) INDICATE UNVERIFIED DIMENSIONS AND ARE <br />APPROXIMATE. NOTIFY ARCHITECT IMMEDIATELY OF CONFLICTS OR EXCESSIVE VARIATIONS <br />FROM INDICATED DIMENSIONS. NOTED DIMENSIONS TAKE PRECEDENCE OVER SCALED <br />DIMENSIONS --DO NOT SCALE DRAWINGS. DIMENSIONS OF EXISTING CONDITIONS MAY BE <br />BASED ON RECORD DRAWINGS AND ARE TO BE FIELD -VERIFIED BY THE CONTRACTOR. <br />CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS BEFORE COMMENCING ANY <br />DEMOLITION. CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL <br />STRUCTURAL MEMBERS, EXISTING CONSTRUCTION AND SOIL EXCAVATIONS, AS REQUIRED, <br />AND IN A MANNER SUITABLE TO THE WORK SEQUENCE. TEMPORARY SHORING AND BRACING <br />SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN <br />ACCORDANCE WITH THE DRAWINGS AND MATERIALS HAVE ACHIEVED DESIGN STRENGTH. <br />NO REINFORCING BARS IN EXISTING CONSTRUCTION SHALL BE CUT UNLESS DIRECTED TO <br />BY THE ARCHITECT OR AS SHOWN ON THE DRAWINGS. <br />CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, <br />TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED TO PERFORM THE WORK. <br />STRUCTURAL STEEL <br />REFERENCE SPECIFICATIONS <br />STRUCTURAL STEEL <br />AISC 360 - SPECIFICATION FOR STRUCTURAL STEEL <br />BUILDINGS <br />HIGH STRENGTH BOLTS <br />RCSC SPECIFICATION FOR STRUCTURAL JOINTS USING <br />HIGH -STRENGTH BOLTS <br />WELDING <br />AWS D1.1, TYPICAL <br />AWS D1.3 FOR STEEL DECK AND COLD -FORMED FRAMING <br />AWS D1.8 FOR SUPPLEMENTAL SEISMIC PROVISIONS <br />AWS PREQUALIFIED JOINT DETAILS <br />WELDER CERTIFICATION <br />AMERICAN WELDING SOCIETY (AWS) <br />WASHINGTON ASSOCIATION OF BUILDING OFFICIALS <br />(WABO) <br />STEEL DECKING <br />STEEL DECK INSTITUTE PUBLICATION NO. FDDM <br />STEEL DECK INSTITUTE PUBLICATION NO. RDDM <br />AISI S100- NORTH AMERICAN SPECIFICATION FOR THE <br />DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS <br />STEEL MATERIALS <br />WIDE FLANGE SHAPES (W AND WT) ASTM A 992 <br />PLATES (PL), BARS ASTM A 36 TYPICAL, <br />ASTM A 572 GRADE 50 WHERE NOTED <br />ANGLES (L), CHANNELS (C AND MC) ASTM A 36 <br />STRUCTURAL TUBES (HSS) ASTM A 500, GRADE C <br />STRUCTURAL BOLTS ASTM F 3125, GRADE A 325 <br />THREADED RODS ASTM A 36, UNLESS NOTED OTHERWISE <br />WELDING ELECTRODES 70 KSI, LOW HYDROGEN, TYPICAL <br />60 KSI, MINIMUM, STEEL DECK AND COLD -FORMED <br />FRAMING <br />STRUCTURAL STEEL DESIGN, FABRICATION AND ERECTION SHALL CONFORM TO THE <br />REQUIREMENTS OF IBC CHAPTER 22. ALL MEMBERS ARE TO BE ERECTED WITH NATURAL <br />MILL CAMBER OR INDUCED CAMBER UP, UNLESS OTHERWISE NOTED ON THE PLANS. <br />SUBSTITUTION OF MEMBER SIZES OR STEEL GRADE WILL NOT BE ALLOWED WITHOUT PRIOR <br />APPROVAL BY THE ARCHITECT. A MINIMUM OF TWO BOLTS IS REQUIRED FOR ALL BEAM <br />CONNECTIONS. ALTERNATIVE CONNECTIONS TO THOSE SHOWN ON THESE DRAWINGS WILL <br />REQUIRE PRIOR APPROVAL BY THE ARCHITECT. <br />THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ERECTION AIDS AND JOINT <br />PREPARATIONS THAT INCLUDE, BUT ARE NOT LIMITED TO, ERECTION ANGLES, LIFT HOLES <br />AND OTHER AIDS, WELDING PROCEDURES, REQUIRED ROOT OPENINGS, ROOT FACE <br />DIMENSIONS, GROOVE ANGLES, BACKING BARS, COPES, SURFACE ROUGHNESS VALUES, <br />AND UNEQUAL PARTS. <br />WELDING <br />ALL WELDING SHALL BE IN CONFORMANCE WITH AISC AND AWS STANDARDS, AND SHALL BE <br />PERFORMED BY AWS-WABO-CERTIFIED WELDERS. ONLY WELDS THAT ARE PREQUALIFIED, <br />AS DEFINED BY AWS, OR QUALIFIED BY TESTING SHALL BE USED. SHOP DRAWINGS SHALL <br />SHOW ALL WELDING WITH AWS A2.4 SYMBOLS. WELDS SHOWN ON THE DRAWINGS ARE <br />MINIMUM SIZES. INCREASE WELD SIZE TO AWS MINIMUM SIZES BASED ON THICKNESS. <br />MINIMUM WELD SIZE SHALL BE 3/16-INCH, UNLESS NOTED OTHERWISE. THE WELDS SHOWN <br />ARE FOR THE FINAL CONNECTIONS. FIELD WELD SYMBOLS ARE SHOWN WHERE FIELD <br />WELDS ARE REQUIRED BY THE STRUCTURAL DESIGN. WHERE FIELD WELD IS NOT <br />INDICATED, THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING IF A WELD SHOULD BE <br />SHOP OR FIELD -WELDED IN ORDER TO FACILITATE THE STRUCTURAL STEEL ERECTION. <br />FIREPROOFING <br />EXCEPT WHERE PAINTED OR GALVANIZED, STRUCTURAL STEEL SHALL BE FIREPROOFED <br />PER THE SPECIFICATIONS. FIREPROOFING SHALL BE GCP APPLIED TECHNOLOGIES OR <br />APPROVED EQUAL. THICKNESS SHALL BE AS INDICATED ON ICC REPORT NO. ESR-1186. <br />PRIMARY STRUCTURAL FRAME CONSISTS OF ALL COLUMNS, GIRDERS AND BEAMS <br />ATTACHED TO COLUMNS, AND ANY BEAM CARRYING GREATER THAN 500 SQUARE FEET OF <br />FLOOR OR ROOF AREA. ALL OTHER FRAMING IS TO BE CONSIDERED SECONDARY. <br />STRUCTURAL MEMBERS SHALL BE ASSUMED TO BE IN A THERMAL UNRESTRAINED <br />CONDITION FOR THE PURPOSES OF DETERMINING FIREPROOFING THICKNESS. <br />CONCRETE <br />CONCRETE WORK SHALL CONFORM TO ALL REQUIREMENTS OF IBC CHAPTER 19. <br />CONCRETE MIXTURES <br />CONCRETE MIXTURES SHALL CONFORM TO THE FOLLOWING REQUIREMENTS: <br />CONCRETE MIXTURES <br />f'c <br />(PSI) <br />TEST AGE <br />(DAYS) <br />EXPOSURE <br />CLASS <br />USE <br />F <br />S <br />W <br />C <br />4,000 <br />28 <br />1 FO <br />I SO <br />I WO <br />I CO <br />I SLAB -ON -GRADE <br />CONCRETE MIXTURES SHALL CONFORM TO THE MOST STRINGENT REQUIREMENTS FOR <br />EXPOSURE CLASSES SPECIFIED IN THE TABLE ABOVE AND ACI 318 TABLE 19.3.2.1. <br />WATER -REDUCING ADMIXTURES MAY BE INCORPORATED IN CONCRETE MIX DESIGNS, BUT <br />SHALL CONFORM TO ASTM C 494, AND BE USED IN STRICT ACCORDANCE WITH THE <br />MANUFACTURER'S RECOMMENDATIONS. CaC12 OR OTHER WATER-SOLUBLE CHLORIDE <br />ADMIXTURES SHALL NOT BE USED. <br />WATER/CEMENTITIOUS MATERIALS RATIO SHALL BE MEASURED BY WEIGHT AND SHALL BE <br />BASED ON THE TOTAL CEMENTITIOUS MATERIAL. WATER/CEMENTITIOUS MATERIALS RATIO <br />AND WATER CONTENT SHALL BE DETERMINED BY THE SUPPLIER BASED ON STRENGTH <br />REQUIREMENTS AND SHALL NOT EXCEED THE MAXIMUM WATER/CEMENTITIOUS MATERIAL <br />RATIO AND/OR WATER CONTENT IF SHOWN ABOVE OR IN ACI 318 TABLE 19.3.2.1 FOR THE <br />EXPOSURE CLASSES LISTED. <br />FIELD -MEASURED SLUMP SHALL CONFORM TO THE SUBMITTED CONCRETE MIX DESIGN. <br />TOLERANCE OF SLUMP SHALL CONFORM TO ASTM C 94. <br />THE CONTRACTOR SHALL SUBMIT CONCRETE MIX DESIGNS FOR APPROVAL 2 WEEKS PRIOR <br />TO PLACING ANY CONCRETE. THE MIX DESIGN SHALL BE IN CONFORMANCE WITH ACI 318, <br />CHAPTER 19. THE SUBMITTAL SHALL IN <br />WHERE EACH CONCRETE MIX IS TO BE USED <br />ON THE PROJECT, AS WELL AS THE MAXIMUM AGGREGATE SIZE OF EACH MIX. MAXIMUM <br />AGGREGATE SIZE SHALL CONFORM TO THE PROJECT SPECIFICATIONS. <br />CURING <br />IF THE AIR TEMPERATURE WILL EXCEED 75 DEGREES F WITHIN 48 HOURS OF PLACING <br />CONCRETE, A MOIST CURE SHALL BE APPLIED TO THE CONCRETE FOR A PERIOD OF 36 <br />HOURS AFTER FINISHING CONCRETE SURFACES. REFER TO THE PROJECT SPECIFICATIONS <br />FOR CURING REQUIREMENTS. <br />REINFORCING STEEL <br />DEFORMED BARS ASTM A 615, GRADE 60 <br />REINFORCING SHALL BE SUPPORTED AS SPECIFIED BY THE PROJECT SPECIFICATIONS AND <br />THE CRSI MANUAL OF STANDARD PRACTICE. REINFORCING STEEL SHALL BE DETAILED IN <br />ACCORDANCE WITH ACI STANDARD OF PRACTICE AS OUTLINED IN ACI 315, "GUIDE TO <br />PRESENTING REINFORCING STEEL DESIGN DETAILS". <br />NONSHRINK GROUT <br />BASE PLATE GROUT SHALL BE NONSHRINK TYPE WITH MINIMUM fc = 8,000 PSI. ALL OTHER <br />NONSHRINK GROUT SHALL HAVE MINIMUM fc = 5,000 PSI. <br />STEEL DECK <br />STEEL DECK SHALL CONFORM TO ASTM A 653. WHERE THE DECK IS LEFT PERMANENTLY <br />EXPOSED, GALVANIZED COATING SHALL CONFORM TO ASTM A 924, G90. IN OTHER AREAS, <br />GALVANIZED COATING SHALL CONFORM TO ASTM A 924, G60. STEEL DECK SHALL CONFORM <br />TO THE FOLLOWING: <br />f. (Psh USE <br />33,000 MINIMUM NONCOMPOSITE STEEL ROOF DECK <br />DECK SUPPLIER SHALL VERIFY DECK GAUGES AND CAPACITIES BASED ON ACTUAL DECK <br />LAYOUT AND SPAN CONDITIONS INCLUDING A 10 PSF SUPERIMPOSED DEAD LOAD <br />ALLOWANCE FOR THE STEEL ROOF DECK. DEVIATIONS IN DECK GAUGES FROM THOSE <br />SHOWN SHALL BE SUBMITTED TO THE ARCHITECT, ALONG WITH A VALID ICC REPORT FOR <br />APPROVAL PRIOR TO SHOP DETAILING. <br />DECK WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3, "STRUCTURAL WELDING CODE - <br />SHEET STEEL." ARC SPOT WELD SIZES NOTED ARE BASED ON THE NOMINAL (VISIBLE) <br />DIAMETER. <br />CONTRACTOR SHALL PROVIDE CLOSURE PLATES, FLASHING, AND ALL MISCELLANEOUS <br />COLD -FORMED FRAMING NECESSARY TO COMPLETE THE WORK. THE MINIMUM BEARING <br />SHALL BE 2 INCHES. <br />NONCOMPOSITE STEEL ROOF DECK <br />STEEL ROOF DECK SHALL BE OF THE SIZE AND GAUGE SHOWN ON THE PLANS OR AN <br />APPROVED EQUAL. STEEL ROOF DECK FASTENING SHALL BE AS SHOWN ON THE PLANS. THE <br />MINIMUM END LAP SHALL BE 21NCHES CENTERED OVER SUPPORTS. <br />SUSPENDED CEILINGS, LIGHT FIXTURES, PIPES, DUCTS, MECHANICAL OR ELECTRICAL <br />EQUIPMENT, OR OTHER UTILITIES SHALL NOT BE SUPPORTED BY THE NONCOMPOSITE <br />STEEL ROOF DECK WITHOUT APPROVAL OF THE ENGINEER. <br />HOLES OR COMBINATIONS OF HOLES IN NONCOMPOSITE STEEL ROOF DECK, WHICH CUT <br />TWO WEBS WHICH ARE CLOSER THAN 24 INCHES ON CENTER IN ANY DECK SPAN, MAY <br />REQUIRE DECK REINFORCEMENT AND REQUIRE DIRECTION FROM THE ENGINEER. <br />DRAWING LIST <br />S-3.0 <br />STRUCTURAL NOTES, DRAWING LIST, AND SPECIAL <br />INSPECTIONS <br />S-3.1 <br />LEVEL 1 PARTIAL PLAN <br />S-3.2 <br />LEVEL 2 PARTIAL PLAN <br />S-3.3 <br />STAIR PLAN & DETAILS <br />S-3.4 <br />OPERABLE PARTITION PLAN & DETAILS <br />S-3.5 <br />WALL OPENING DETAILS <br />STRUCTURAL DRAWING SYMBOLS AND ABBREVIATIONS <br />ADD'L <br />ADDITIONAL <br />IN <br />INCH <br />ADH <br />ADHESIVE <br />INFO <br />INFORMATION <br />ADJ <br />ADJUSTABLE <br />INT <br />INTERIOR <br />AESS <br />ARCHITECTURALLY EXPOSED <br />JT <br />JOINT <br />STRUCTURAL STEEL <br />K <br />KIP (1,000 LBS.) <br />AFF <br />ABOVE FINISH FLOOR <br />KSF <br />KIPS PER SQUARE FOOT <br />ARCH <br />ARCHITECTURAL <br />LFH <br />LONG FACE HORIZONTAL <br />B/ <br />BOTTOM OF <br />LLH <br />LONG LEG HORIZONTAL <br />BLDG <br />BUILDING <br />LLV <br />LONG LEG VERTICAL <br />SM <br />BEAM <br />LNGT <br />LONGITUDINAL <br />BOT <br />BOTTOM <br />LP <br />LOW POINT <br />BRG <br />BEARING <br />MAX <br />MAXIMUM <br />BTWN <br />BETWEEN <br />MECH <br />MECHANICAL <br />C <br />CAMBER <br />MFR <br />MANUFACTURER <br />CAP <br />CAPACITY <br />MIN <br />MINIMUM <br />CC <br />CENTER TO CENTER <br />MISC <br />MISCELLANEOUS <br />CFS <br />COLD -FORMED STEEL <br />MOM <br />MOMENT <br />CJP <br />COMPLETE JOINT PENETRATION <br />NIC <br />NOT IN CONTRACT <br />CL <br />CENTERLINE <br />NO <br />NUMBER <br />CLG <br />CEILING <br />NOM <br />NOMINAL <br />CLR <br />CLEAR <br />NS <br />NEARSIDE <br />CMU <br />CONCRETE MASONRY UNIT <br />NTS <br />NOT TO SCALE <br />COL <br />COLUMN <br />OC <br />ON CENTER <br />CONC <br />CONCRETE <br />OPNG <br />OPENING <br />CONN <br />CONNECTION <br />OPP <br />OPPOSITE <br />CONST <br />CONSTRUCTION <br />PAF <br />POWER ACTUATED FASTENER <br />CONT <br />CONTINUOUS <br />PEN <br />PENETRATION <br />CONTR <br />CONTRACTOR <br />PJP <br />PARTIAL JOINT PENETRATION <br />CONTY <br />CONTINUITY <br />PL <br />PLATE <br />COORD <br />COORDINATE <br />PSF <br />POUNDS PER SQUARE FOOT <br />CTR <br />CENTER <br />PSI <br />POUNDS PER SQUARE INCH <br />DBL <br />DOUBLE <br />R <br />RADIUS <br />DCW <br />DEMAND CRITICAL WELD <br />REINF <br />REINFORCING <br />DEMO <br />DEMOLISH <br />REM <br />REMAIN(DER) <br />DET <br />DETAIL <br />REQ'D <br />REQUIRED <br />DIA <br />DIAMETER <br />RTN <br />RETURN <br />DIAG <br />DIAGONAL <br />Sc <br />SLIP CRITICAL <br />DN <br />DOWN <br />SCHED <br />SCHEDULE <br />DO <br />DITTO <br />SDCI <br />SEATTLE DEPARTMENT OF <br />DWF <br />DEFORMED WIRE FABRIC <br />CONSTRUCTION AND INSPECTIONS <br />DWG <br />DRAWING <br />SDQ <br />SPECIAL DUCTILE QUALITY <br />DWL <br />DOWEL <br />SECT <br />SECTION <br />EA <br />EACH <br />SFRS <br />SEISMIC FORCE -RESISTING SYSTEM <br />EF <br />EACH FACE <br />BHT <br />SHEET <br />EL <br />ELEVATION <br />SIM <br />SIMILAR <br />EQ <br />EQUAL <br />SP <br />SPACE <br />EQUIP <br />EQUIPMENT <br />SPEC <br />SPECIFICATION <br />ES <br />EACH SIDE <br />SQ <br />SQUARE <br />EW <br />EACH WAY <br />STD <br />STANDARD <br />EX <br />EXISTING <br />STIFF <br />STIFFENER <br />EXT <br />EXTERIOR <br />STL <br />STEEL <br />F <br />FAHRENHEIT <br />STRUCT <br />STRUCTURAL <br />FF <br />FINISH FLOOR <br />SUPP <br />SUPPORT <br />FIN <br />FINISH <br />SYM <br />SYMMETRICAL <br />FLG <br />FLANGE <br />T&B <br />TOP AND BOTTOM <br />FLR <br />FLOOR <br />T/ <br />TOP OF <br />FS <br />FARSIDE <br />THK <br />THICK(NESS) <br />FT <br />FEET <br />THRU <br />THROUGH <br />GA <br />GAUGE <br />TRANS <br />TRANSVERSE <br />GALV <br />GALVANIZED <br />TYP <br />TYPICAL <br />GEN <br />GENERAL <br />LINO <br />UNLESS NOTED OTHERWISE <br />GR <br />GRADE <br />UT <br />ULTRASONIC TESTING <br />GWB <br />GYPSUM WALL BOARD <br />VERT <br />VERTICAL <br />HGR <br />HANGER <br />VIF <br />VERIFY IN FIELD <br />HK <br />HOOK <br />W <br />W-SHAPE <br />HORIZ <br />HORIZONTAL <br />W/ <br />WITH <br />HP <br />HIGH POINT <br />W/O <br />WITHOUT <br />HSS <br />HOLLOW STRUCTURAL SECTION <br />WP <br />WORK POINT <br />IBC <br />INTERNATIONAL BUILDING CODE <br />STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TESTING <br />SPECIAL INSPECTIONS <br />AND TESTING SCHEDULE <br />ESTABLISHED PER IBC 2018 SECTION 109 AND CHAPTER 17 <br />ITEM <br />IBC CODE <br />COMMENTS <br />INSPECTION IN FABRICATION SHOP <br />1704.2.5 <br />- <br />STRUCTURALSTEEL <br />1705.2 <br />- <br />FABRICATION AND ERECTION <br />- <br />HIGH STRENGTH BOLTING <br />_ <br />WELDING <br />CONCRETE <br />1705.2 <br />POST -INSTALLED ADHESIVE ANCHORS <br />STEEL DECK <br />1705.2.2 <br />- <br />GENERAL SYMBOLS <br />10 <br />1 <br />S3.1 <br />100'-0" <br />100'-0" <br />100'-0" <br />T/SLAB <br />LEVEL 01 n <br />,WP <br />GRID BUBBLE <br />NORTH ARROW <br />STANDARD SECTION CUTS <br />BUILDING SECTION CUTS <br />ELEVATION OF WALL OR FRAME <br />SPOT ELEVATION: TOP OF PLYWOOD <br />TOP OF CONCRETE <br />TOP OF STEEL <br />TOP OF CONCRETE ELEVATION <br />TOP OF STEEL ELEVATION <br />REFERENCE ELEVATION. REFER TO PLAN <br />UNLESS NOTED OTHERWISE. <br />ELEVATION OF LEVEL <br />WORKPOINT <br />DIRECTION OF DOWNWARD SLOPE <br />DIRECTION OF SPAN <br />EXISTING FRAMING <br />STEEL SYMBOLS <br />I0 O <br />STEEL COLUMN ABOVE OR PASSING THRU THIS LEVEL <br />�- - <br />STEEL COLUMN BELOW THIS LEVEL <br />T <br />COLUMN SPLICE PER FRAME ELEVATIONS <br />DCOLUMN <br />SPLICE TYPE <br />4 D 1/2" <br />DOUBLER PLATE PER FRAME ELEVATIONS <br />4_1 <br />3/4" <br />STIFFENER PLATES PER FRAME ELEVATIONS <br />D 1/2" <br />BOTH DOUBLER &STIFFENER PLATES <br />iti <br />S 3/4" <br />® <br />STEEL IN CROSS SECTION <br />TOP OF STEEL <br />CAMBER AT MID -SPAN <br />ELEVATION <br />DEVIATION FROM <br />NUMBER OF STUDS <br />TYPICAL <br />BEAM SIZE <br />SPECIAL MOMENT <br />RESISTING FRAME <br />COLUMN <br />CONNECTION <br />BELOW �-- <br />W24x55 [20] C 3/4" (-10") <br />n <br />I <br />I <br />I <br />FULL HEIGHT <br />PLATE <br />CONNECTION O <br />FH <br />SPECIAL STUD <br />SPACING FOR vi <br />GIRDERS �Iu <br />BRACED xl <br />FRAME <br />ABOVE T I <br />BRACED <br />FRAME BELOW <br />NUMBER OF BOLTS IN <br />SPECIAL CONNECTIONS - <br />MOMENT OR TENSION <br />RESISTING <br />CONNECTION <br />BEAM <br />�? PENETRATION <br />MEMBER OF THE <br />n SEISMIC FORCE - <br />RESISTING SYSTEM <br />N <br />3 <br />BOT FLANGE <br />BEAM BRACE <br />1N <br />SHOP WELDED <br />NUMBER OF BOLTS IN CANTILEVER <br />CONNECTION IF <br />DIFFERENT FROM TYPICAL <br />SCHEDULE <br />U <br />LU <br />T� <br />1 <br />U/�// <br />LL <br />Q <br />U <br />C^ <br />10 <br />O <br />N <br />ZAP ENERGY <br />Opus Seaway <br />Floor 1 & 2 <br />2300 Merrill Creek Pkwy <br />Everett. WA <br />DESIGN: <br />DRAWN: <br />CHECKED: <br />NO.: 2300091 <br />WAYNE <br />WASy� o�I� <br />c <br />Pp ''Pp 48649 <br />F�SS10NAL <br />ANo Issue DesCNDtIon Date <br />PERMIT SET 02-17-2023 <br />STRUCTURAL NOTES, <br />DRAWING LIST, AND <br />SPECIAL INSPECTIONS <br />S-3.0 <br />