Laserfiche WebLink
SCOPE OF WORK <br />INSTALL A 3 NEW POWER SUPPLY FOR <br />FUTURE USE AS SHOWN ON DRAWING <br />maw <br />IIIIIIII�©IIIIIIIIIIIIIIIII,IIIIII�IIIIII�I <br />oo�m <br />00�0 <br />Fire Alarm General xores <br />ee aao. <br />�mrgvm wasbo xmwmea <br />al rn,a���,.,,,na � m wexeme,l reM„ao.a, xac 70 <br />r=,we�.brml. <br />m kyemsiun x s�nlieapraemm� seculry <br />nabnetl by the rorresP'�uNieU p'alen W II Ee NxsM4aM <br />FIRE ALARM SEQUENCE OF OPERATION <br />CEILINGDECK <br />VViV® <br />CEILING MOUNTED <br />SUSPENDED CEILING <br />® <br />SEE NOTE <br />t <br />CEILING MOUNTED <br />SEE NOTE <br />CEILING MOUNTED <br />CEILING MOUNTED <br />SEE NOTE <br />SEE NOTE <br />0 <br />MAX 30'-0' <br />(360") <br />SEE NOTE <br />F_ <br />RPS FACP <br />MAX S'-0' <br />(g0") (72')& <br />SEE NOTE <br />MIN S'fi' <br />!1 O <br />(6l") <br />MAX 4-11 <br />(43") <br />MIN ' S- <br />(42') <br />FINISHED FLOOR <br />ijiw` <br />1. COORDINATE EX ACT MOUNTING HEIGHT OF POWER SUPPLIES WITH THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND AHJ PRIOR TO INSTALLATION. <br />2. MEASURED TO THE OPERABLE PART OF THE PULL STATION. <br />3. WHERE INDICATED ON THE DRAWINGS - LOCATE CEILING MOUNTED NOTIFICATION APPLIANCES FLUSH WITH THE SUSPENDED CEILING; ALIGNED WITH LIGHTING, <br />SPRINKLERS, AND OTHER ARCHITECTURAL FIXTURES; WITH CLEAR LINE OF SITE IN ALL DIRECTIONS; NO GREATER THAN THIRTY (30) FEET ABOVE THE FINISHED <br />FLOOR', AND AS INDICATED IN NFPA 72. <br />4. WHERE INDICATED ON THE DRAWINGS- LOCATE CEILING MOUNTED SMOKE DETECTORS ON THE BOTTOM OF THE DECKISUSPENDED CEILING (NOT ON BOTTOM OF <br />STRUCTURAL MEMBERS), AND AS INDICATED IN NFPA 72, <br />5. WHERE INDICATED ON THE DRAWINGS LOCATE CEILING MOUNTED NOTIFICATION APPLIANCES ON BOTTOM OF BEAMS OR JOISTS; WITH CLEAR LINE OF SITE IN ALL <br />DIRECTIONS; NO GREATER THAN THIRTY (W) FEET MOVE THE FINISHED FLOOR; AND AS INDICATED IN NFPA 72. <br />FIRE ALARM <br />CABLING <br />I -CONDUIT <br />NOTES: <br />1. ALL OPEN FIRE ALARM CABLING SHALL BE CONCEALED FROM PUBLIC VIEW. <br />2. FIRE ALARM CABLE SHALL NOT BE PAINTED. <br />OPEN FIRE ALARM CABLING DETAIL 05 <br />SOURCE: Ver. 2013.A NOT TO SCALE <br />NOTES: <br />1. FOR CEILING MOUNTED SMOKE DETECTORS AND OCCUPANT NOTIFICATION APPLIANCES IN AREAS WITH <br />SUSPENDED CEILINGS. <br />JUNCTION BOX MOUNTING DETAIL <br />Permit#: FA2307-005 <br />Site Address: <br />2300 Merrill Creek <br />Applicant: <br />Amanda Shards <br />Application Date: 07/12/2023 <br />Description: <br />Install 3 New Power Supplies <br />Review Status: <br />1 at Review by City & Peer Reviewers <br />Review Date: <br />07/12/2023 <br />EVERETT <br />Everett Fire Dept. Permit Review <br />Status: Approved <br />Reviewed By: KBrown <br />07/12/2023 3:14:55 <br />PM <br />REVISION DATE <br />6/23/2023 <br />DRAWN BY <br />SCO17HARRIS <br />All designs/plans listed are thesole propentyof Meridian <br />Secmity and are for use by Mendian Sennity only, unless <br />oNerwise n oted. We r,,erve the right to make,hang,,or <br />corrections. <br />STEVEN M DELIMONT <br />NICET IIII ID #132990 <br />WA STATE <br />JOURNEYMAN# <br />DELIMSM98ORG <br />FA01 <br />