Laserfiche WebLink
TFP172 <br />Page 2of4 <br />Components: *Temperature rating is ** Pipe thread connections per ISO 7-1 <br />1 - Frame 4 - Bulb indicated on Deflector. can be provided on special request. <br />2 - Button 5 - Compression STYLE 15 or 20 <br />3 - Sealing Screw ESCUTCHEON PLATE 1/2" 7/16" (11,1 mm) RECESSED <br />Assembly 6 - Deflector* DEFLECTOR* SEATING SURFACE NPT** NOMINAL MAKE -IN ESCUTCHEON <br />6* } I- <br />5 7/16" <br />(11,1 mm) <br />4 NOMINAL 2" J <br />MAKE -IN (50,8 mm) <br />2 2" di rI1-3/8" <br />3 (50,8 mm) (34,9 mm) <br />WR <br />FI <br />1 1 - - <br />1/2" NPT** DEFLECTOR * 2-7/8" (73,0 mm) DIA. <br />CROSS SECTION UPRIGHT PENDENT RECESSED PENDENT <br />FIGURE 1 <br />SERIES TY-FRB UPRIGHT (TY313) AND PENDENT (TY323) SPRINKLERS <br />5.6 K-FACTOR, 112 INCH NPT, QUICK RESPONSE <br />ZENCH RECESS <br />USE ONLY <br />END "A") <br />FIGURE 2 <br />W-TYPE 6 <br />SPRINKLER WRENCH <br />WRENCH <br />RECESS <br />PUSH WRENCH <br />IN TO ENSURE <br />ENGAGEMENT <br />WITH SPRINKLER <br />WRENCHING AREA <br />FIGURE 3 <br />W-TYPE 7 RECESSED <br />SPRINKLER WRENCH <br />Installation <br />The TYCO Series TY-FRB, 5.6 K-factor, <br />Upright (TY313) and Pendent (TY323) <br />Sprinklers must be installed in accor- <br />dance with this section. <br />General Instructions <br />Do not install any bulb -type sprin- <br />kler if the bulb is cracked or there is <br />a loss of liquid from the bulb. With the <br />sprinkler held horizontally, a small air <br />bubble should be present. The diam- <br />eter of the air bubble is approximately <br />1/16 in. (1,6 mm) forthe 135°F (57°C) and <br />3/32 in. (2,4 mm) for the 286°F (141 °C) <br />temperature ratings. <br />A leak -tight 1/2 in. NPT sprinkler joint <br />should be obtained by applying a <br />minimum to maximum torque of 7 to <br />14 lb-ft (9,5 to 19,0 N•m). Higher levels <br />of torque can distort the sprinkler Inlet <br />with consequent leakage or impairment <br />of the sprinkler. <br />Do not attempt to compensate for <br />insufficient adjustment in the Escutch- <br />eon Plate by under- or over -tightening <br />the sprinkler. Re -adjust the position of <br />the sprinkler fitting to suit. <br />Upright and Pendent Sprinklers <br />The Series TY-FRB Upright and <br />Pendent Sprinklers must be installed <br />in accordance with the following <br />instructions. <br />Step 1. Install Pendent sprinklers in the <br />pendent position. Install upright sprin- <br />klers in the upright position. <br />Step 2. With pipe -thread sealant <br />applied to the pipe threads, hand - <br />tighten the sprinkler into the sprinkler <br />fitting. <br />Step 3. Tighten the sprinkler into the <br />sprinkler fitting using only the W-Type <br />6 Sprinkler Wrench (Figure 2). With ref- <br />erence to Figure 1, apply the W-Type 6 <br />Sprinkler Wrench to the wrench flats. <br />Torque sprinklers 7 to 14 lb-ft (9,5 to <br />19,0 N•m). <br />Recessed Pendent Sprinklers <br />The Series TY-FRB Recessed Pendent <br />Sprinklers must be installed in accor- <br />dance with the following instructions. <br />Step A. After installing the Style 15 <br />or Style 20 Mounting Plate over the <br />sprinkler threads, and with pipe -thread <br />sealant applied to the pipe threads, <br />hand -tighten the sprinkler into the <br />sprinkler fitting. <br />Step B. Tighten the sprinkler into the <br />sprinkler fitting using only the W-Type <br />7 Recessed Sprinkler Wrench (Figure <br />3). With reference to Figure 1, apply the <br />W-Type 7 Recessed Sprinkler Wrench <br />to the sprinkler wrench flats. Torque <br />sprinklers 7 to 14 lb-ft (9,5 to 19,0 N•m). <br />Step C. After ceiling installation and <br />finishing, slide on the Style 15 or Style <br />20 Closure over the Series TY-FRB <br />Sprinkler and push the Closure over the <br />Mounting Plate until its flange comes in <br />contact with the ceiling. <br />