My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 2:53:14 PM
Creation date
8/24/2023 9:02:54 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
7 <br />ABBREVIATIONS <br />ADJ Adjustable <br />A Above Finished Floor <br />AHJ Authority Having Jurisdiction <br />ANSI American National Standards Institute <br />AS Automatic Sprinklers <br />ASME American Society of Mechanical Engineers <br />ASR Automatic Sprinkler Riser <br />ASTM American Society for Testing and Materials <br />ATR All Thread Rod <br />AUX Auxiliary <br />AV Alarm Valve <br />AWS American Welding Society <br />BB Below Beam <br />BD Below Deck <br />BFP Backnow Preventor <br />BFV Butterfly Valve <br />BJ Below Joist <br />BL Branchline <br />BLDG Building <br />BOR Base Of Riser <br />SR Brass <br />CH Chrome <br />Cl Cast Iron <br />CL Centerline <br />COJ Cut On Job <br />COL Column <br />CONC Concrete <br />COUP Coupling <br />CPVC Chlorinated Polyvinyl Chloride <br />CSP Combination Standpipe <br />CSR Coach Screw Rod <br />CTR Center <br />CV Check Valve <br />DCV Detector Check Valve <br />DI Ductile Iron <br />ON Down <br />DSP Dry Standpipe <br />E Existing <br />EC Extended Coverage <br />ELEV Elevation <br />ELL Elbow Fitting <br />EQB Earthquake Brace <br />EXP Exposed <br />F Flanged <br />FDC Fire Department Connection <br />FH Fire Hydrant <br />FHC Fire Hose Cabinet <br />FHV Fire Hose Valve <br />FILE Floor <br />FM Factory Mutual Research <br />POW Face Of Wall <br />FP Fire Protection <br />FS Flow Switch <br />FT Foot <br />FTO Field To Order <br />G Grooved <br />GA Gauge <br />GALV Galvanized <br />GB Glass Bulb <br />GOE Groove One End <br />GOL Groove-O-Let <br />GPM Gallons Per Minute <br />GIRD Grooved Reducing Coupling <br />GV Gate Valve <br />HDI HIM Drop -in Anchor <br />HOW Horizontal Sidewall <br />HT Height <br />HV Hose Valve <br />ID Inside Diameter <br />MECH Mechanical <br />MJ Mechanical Joint <br />MRA Most Remote Area <br />MT Mechanical Tee <br />NFPA National Fire Protection Association <br />NIC Not In Contract <br />NO Number <br />NPT National Pipe Thread <br />NTS Not To Scale <br />OC On Center <br />OD Outside Diameter <br />OH Ordinary Hazard <br />OS&Y Outside Screw & Yoke <br />P Plain End <br />PIV Post Indicator Valve <br />PL Property Line <br />POC Point Of Connection <br />PRV Pressure Regulating Valve <br />PS Pressure Switch <br />PSI Pounds Per Square Inch <br />PVC Polyvinyl Chloride <br />OR Quick Response <br />RES Residential <br />RN Riser Nipple <br />SBB Side Beam Bracket <br />SCH Schedule <br />SHT Sheet <br />SP Standpipe <br />SPK Sprinkler <br />SO Square <br />SR Standard Response <br />SSP Standard Spray Pendent <br />SSU Standard Spray Upright <br />SW Switch <br />T Thread <br />TEE Tee Fitting <br />TLW Threaded Lightwall <br />TOE Thread One End <br />TOR Top Of Riser <br />TW Thinwall <br />TYP Typical <br />SYMBOL LEGEND <br />Upright Sprinkler on Line - New <br />® Upright Sprinkler - Existing <br />With 1" Outlet - Existing <br />• <br />Pendent Sprinkler on 1" Drop - New <br />to 2 <br />$Z <br />F— <br />Z J <br />® <br />Pendent Sprinkler on 1" Drop - Exisitng <br />oZ <br />Z <br />I� <br />Pipe Diameter (inches) <br />w p <br />5-0 <br />New Sprinkler Branchline - New <br />W p <br />—Pipe Length (feet -Inches) <br />wLL <br />4 <br />New Sprinkler Main - New <br />5-o <br />2 <br />W <br />NLU <br />I <br />- � <br />- Sprinkler Piping - Existing <br />N <br />Change in Pipe Elevation <br />® System Riser <br />f Branchline Hanger Location <br />See Hanger Detail for Additional Info <br />12 Hydraulic Reference Point <br />0 Grooved Coupling <br />Grooved Cap <br />3 Threaded Cap <br />Flexible Sprinkler Drop <br />SPRINKLER LEGEND <br />ADJUST SPRINKLER TEMPERATURES AS REQUIRED PER NFPA 13, 2016 PARAGRAPH 8.3.2 <br />SYMBOL MODEL C I KI K_FAr7 r1RIPInp N PT PINICH TPMP TnTAl r`.nMMPNTC <br />® <br />EXISTING UPRIGHT SPRINKLER <br />5.6 <br />1 1/2" <br />1 1/2" <br />1 BRASS <br />20G' <br />® <br />EXISTING PENDENT SPRINKLER <br />5.6 <br />1 1/2" <br />1 1/2" <br />1 BRASS <br />165° <br />• <br />VICTAULIC FL-QR PENDENT SPRINKLER <br />V2708 <br />8.0 <br />1/2" <br />1/2" <br />WHITEPiVHITE <br />155, <br />27 <br />O <br />VICTAULIC FL-QR UPRIGHT SPRINKLER <br />V2704 <br />5.6 <br />1/2" <br />1/2" <br />BRASS <br />200, <br />13 <br />SPRINKLER TOTALS: <br />40 <br />FLEXIBLE SPRINKLER DROP INFORMATION <br />MULTI -PORT BRACKET <br />FLEXHEAD SPRINKLER DROP <br />CORRUGATED STAINLESS STEEL <br />HOSE WITH STAINLESS STEEL <br />BRAID - SEE BELOW FOR MAX. <br />FLEXDROP LENGTH <br />/_ ADJUSTABLE HUB <br />T CEILING <br />--PENDENT SPRINKLER <br />THE MAXIMUM FLEXHEAD LENGTH IS 36" <br />HANGER DETAILS <br />MAXIMUM DISTANCE BETWEEN HANGERS <br />NOMINAL PIPE <br />3/4„ <br />1" <br />1-1/4„ <br />1-1/2„ <br />2„ <br />2-1/2„ <br />3" <br />4„ <br />SIZE (in.) <br />STEEL PIPE EXCEPT <br />N/A <br />12-0 <br />12-0 <br />15-0 <br />15-0 <br />15-0 <br />15-0 <br />15-0 <br />THREADED UGHTWALL <br />THREADED UGHTWALL <br />N/A <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />12-0 <br />STEEL PIPE <br />CPVC PIPE <br />5-6 <br />6-0 <br />6-6 <br />7-0 <br />8-0 <br />9-0 <br />10-0 <br />N/A <br />SAMMY SIDEWINDER SCREW <br />WITH NUT <br />FIG. 100 <br />ALL THREAD ROD <br />FIG. 200 <br />®-,,—FIG. <br />� ADJUSTABLE RING HANGER <br />4®SAMMY SCREW, ROD 4 RING <br />0 Z' PURLIN CONSTRUCTION <br />HANGER ROD SIZES <br />NOMINAL PIPE <br />3/4„ <br />1" <br />1-1/4„ <br />1-1/2„ <br />2„ <br />2-1/2„ <br />3" <br />4„ <br />SIZE (in.) <br />STEEL PIPE EXCEPT <br />N/A <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />THREADED LIGHTWALL <br />THREADED LIGHTWALL <br />N/A <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />3/8" <br />STEEL PIPE <br />/ 2 x TOP CHORD <br />! OR 2x BLOCKING <br />SIDEWINDER <br />SWG 20 (Y;' x 211) <br />G. 100 <br />'8" ALL THREAD ROD <br />200 <br />)JUSTABLE RING HANGER <br />SIDEWINDER(SWG 20), ROD, AND RING <br />WOOD CONSTRUCTION <br />GENERAL NOTES <br />1. The system design and installation shall comply with NFPA 13, 2019 edition, <br />and the Authority Having Jurisdiction. <br />2. Hazard classification: <br />Offices - Light Hazard <br />3. Provide spare sprinklers at existing head cabinet with wrenches. <br />4. All threaded piping to be Eddy -Thread black steel pipe. <br />5. Fittings shall be class 125 threaded cast iron ANSI 616.4. <br />6. All threaded pipe and fittings shall have threads cut to ANSI/ASME standard <br />B1.20.1. <br />7. All pipe welding shall be in compliance with the requirements of AWS B2.1 <br />(standard for building service piping). <br />8. All piping shall be earthquake braced as outlined in NFPA 13 2019. <br />9. Electrical wiring and any painting of the pipe that may be required shall be by <br />others. <br />10. All piping is to be hydrostatically tested at 200 psi minimum, for a period not less <br />than two hours. <br />11. Scope of Work: New Tenant Improvement in an existing building. Provide <br />27 pendent sprinklers and 13 upright sprinklers in new tenant space. <br />r WASNINGI STATE l <br />CERTIFICATE OF COMPETENCY <br />FIRE PROTECTION SPRINKLER SYSTEMS <br />Eric A Price 4/12/23 <br />3437-0508-C Level Date <br />Southeast Fire Protection <br />SOUTHFP878NR Expire• I <br />Evi.c� Pvi.c2 12/91/29 <br />Signature <br />-------- ------------------------ <br />H <br />0 <br />z <br />LL <br />Q <br />LL <br />O <br />LL' <br />~ <br />O <br />m0 <br />LL z <br />� <br />H Q <br />W <br />N <br />i <br />U) <br />a <br />I <br />F <br />0 <br />W <br />U <br />w <br />a <br />J <br />U <br />w <br />N <br />0 <br />UN <br />Z <br />O <br />wit <br />a <br />F <br />y� <br />LL <br />wa <br />U <br />z� <br />U) <br />a $ <br />W <br />0 <br />�O <br />Q0< <br />aj <br />Oa <br />z� <br />Z <br />O <br />V C14 Lf) <br />LO <br />N <br />N fh Z <br />0 <br />d Y <br />o ti LL <br />LU Q <br />Z <br />Hl�a <br />°ate <br />Y <br />QCD <br />2 a <br />Y <br />Z a U <br />=�- <br />W <br />_C)~ <br />QaJ <br />r <br />O <br />fn <br />N <br />j <br />06 <br />O <br />J <br />W <br />W <br />LL <br />w <br />� <br />W <br />Q <br />U <br />W <br />Q <br />J <br />`W <br />J <br />Q <br />W <br />V,w <br />W <br />N <br />U) <br />Cw <br />L <br />a <br />Oo <br />M <br />N <br />REVISIONS <br />A <br />A <br />0 <br />SHEET TITLE <br />FIRE PROTECTION <br />DATE: APRIL 12, 2023 <br />FILE: 32310 <br />FP-1 <br />OF 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.