Laserfiche WebLink
(E)POTTER AFC-100 <br />The Symbol of Protection Fire Alarm Control Panel <br />SLC Loop Accessories <br />The control panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire <br />requirements and may be wired with any wire that complies with the NEC. <br />SLC Loop Devices <br />Device <br />Description <br />PAD200-PD <br />Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.0 to 3.7%/foot. UL 268 7th Edition. <br />PAD200-PHD <br />Combination Analog Photoelectric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.0 to 3.5%/foot <br />obscuration and a fixed temperature range of 1350 to 1850 F heat detector. Smoke detection compliant with UL 268 7th Edition. <br />PAD200-PCD <br />Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon <br />Monoxide detection compliant with UL 2075. <br />PAD200-PCHD <br />Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat <br />detection with a fixed temperature range of 135' to 185' F and is UL 268 and UL 521 7th Edition compliant. Carbon Monoxide <br />detection compliant with UL 2075. <br />PAD100-HD <br />Analog Fixed Temperature (135' - 185°F) or Rate -of -Rise Heat Detector (software selectable). <br />PAD200-DUCTR <br />Addressable Duct Smoke Detector with Form C Relay rate at IOAmps @ 250/120VAC or 8 Amps at 30VDC. <br />PAD200-DUCT <br />Addressable Duct Smoke Detector. <br />PAD 100-6B <br />6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. <br />PAD100-413 <br />4" round base that may be mounted to an electrical box and wired for connection to the above sensors. <br />PAD100-I13 <br />Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. <br />PAD100-RB <br />Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. <br />PAD100-SB <br />Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. <br />PAD100-CD <br />Addressable CO gas detector. <br />PAD 100-DD <br />Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. <br />PAD100-LFSB <br />Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all <br />call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz). <br />PAD100-SPKB <br />Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830134 - REV F • 2/22 PAGE 2 OF 5 <br />