My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 2:53:14 PM
Creation date
8/24/2023 9:02:54 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E)POTTER AFC-100 <br />The Symbol of Protection Fire Alarm Control Panel <br />SLC Loop Accessories <br />The control panel may be connected with up to 100 addressable devices or modules in any combination. The SLC is not restricted by any special wire <br />requirements and may be wired with any wire that complies with the NEC. <br />SLC Loop Devices <br />Device <br />Description <br />PAD200-PD <br />Analog Photoelectric Smoke Detector is a smoke detector with a listed obscuration of 1.0 to 3.7%/foot. UL 268 7th Edition. <br />PAD200-PHD <br />Combination Analog Photoelectric Smoke/Heat Detector — a smoke detector with a listed obscuration of 1.0 to 3.5%/foot <br />obscuration and a fixed temperature range of 1350 to 1850 F heat detector. Smoke detection compliant with UL 268 7th Edition. <br />PAD200-PCD <br />Combination Photoelectric Smoke/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Carbon <br />Monoxide detection compliant with UL 2075. <br />PAD200-PCHD <br />Combination Photoelectric Smoke/Heat/Carbon Monoxide Detector. Smoke detection compliant with UL 268 7th Edition. Heat <br />detection with a fixed temperature range of 135' to 185' F and is UL 268 and UL 521 7th Edition compliant. Carbon Monoxide <br />detection compliant with UL 2075. <br />PAD100-HD <br />Analog Fixed Temperature (135' - 185°F) or Rate -of -Rise Heat Detector (software selectable). <br />PAD200-DUCTR <br />Addressable Duct Smoke Detector with Form C Relay rate at IOAmps @ 250/120VAC or 8 Amps at 30VDC. <br />PAD200-DUCT <br />Addressable Duct Smoke Detector. <br />PAD 100-6B <br />6" round base that is mounted to an electrical box and wired for connection of one of the above sensors. <br />PAD100-413 <br />4" round base that may be mounted to an electrical box and wired for connection to the above sensors. <br />PAD100-I13 <br />Isolator base that interrupts a short in a SLC and prevents the short from affecting protected devices on the loop. <br />PAD100-RB <br />Addressable Relay Base that contains one relay controlled by the SLC. Relay is rated at rated at 2 amps at 30 VDC or 0.5A at 125VAC. <br />PAD100-SB <br />Addressable Sounder Base that contains an addressable sounder module that may be configured for local, group and all call. <br />PAD100-CD <br />Addressable CO gas detector. <br />PAD 100-DD <br />Addressable photoelectric smoke detector for use in DUCT/DUCTR enclosure. <br />PAD100-LFSB <br />Addressable Low Frequency Sounder Base that contains an addressable sounder module that may be configured for local, group and all <br />call. The LFSB complies with the Low Frequency Signal Requirements (520 Hz). <br />PAD100-SPKB <br />Speaker base is a wall or ceiling mount speaker capable of 25 or 70.7 VRMS and is field selectable from 1/8W to 4W. <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830134 - REV F • 2/22 PAGE 2 OF 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.