My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 2:53:14 PM
Creation date
8/24/2023 9:02:54 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
(E)POTTER <br />The Symbol of Protection <br />AFC-100 <br />Fire Alarm Control Panel <br />SLC Features <br />RA-6500R(F) — 4 x 40 LCD annunciator with a key pad in a locked <br />The Potter protocol is a digital protocol with a proven design for <br />metal enclosure. Flush mount version available. <br />reliability and noise immunity. The system does not require special <br />LED-16(F) — 16 LED annunciator with common indicators in a <br />cable or conductors for connection of the Signaling Line Circuit <br />locked metal enclosure. Flush mount version available. <br />as long as the cable is compliant with NFPA 70 and NFPA 72. <br />PSN-1000(E) — 10 amp, remote intelligent power supply with <br />The system allows for Class A or Class B installations as well as <br />6 NACs, 2 Inputs and a P-Link repeater. This panel is listed in <br />"T-Taps", with a max wiring distance of 10,000 Ft. <br />conjunction with the AFC-100 as releasing circuits. <br />CA-6075 — Class A convertor that converts the SLC, NACs and <br />Sensor Features <br />P-Link connection <br />The sensors through the fire alarm control panel provide a real <br />time status as to the condition of the system. The smoke detector <br />sensitivity, heat detector temperature level and drift compensation <br />are all programmable options. The system also allows for a day/night <br />mode where the panel automatically adjusts the sensitivity depending <br />on the time of day. To assist in the reduction of false alarms, the <br />smoke detectors also have a maintenance warning that sends a trouble <br />signal when a detector is dirty to the point that it can no longer <br />maintain the programmed sensitivity. <br />User Interface <br />The fire alarm control panel has a 2 x 16 LCD display to provide <br />information to the system status. The keypad has navigation keys <br />to allow manipulation of the Menu on board the panel. The panel is <br />shipped standard with the following LEDs: <br />• AC Power - Green <br />• Alarm - Red <br />• Earth Fault - Amber <br />• Supervisory - Amber <br />• Silenced - Amber <br />• Trouble - Amber <br />• Pre -Release - Amber <br />• Release - Red <br />The common buttons include a Silence, Reset, Acknowledge, and <br />Drill. All of the buttons are accessible once the locked door is <br />opened. <br />P-Link <br />The AFC-100 has a proprietary communication protocol that <br />communicates through a RS-485 connection to field devices. Up <br />to 32 devices may be connected to a single P-Link connection. The <br />P-Link includes the communication terminals and regulated 24 VDC <br />connection for the field devices. The field devices may be any of the <br />following: <br />SLCE-127 -Nohmi addressable loop expansion module for retrofit <br />applications. <br />UD-2000 — UL listed, Dual line telephone alarm communicator <br />DRV 50 — LED driver expander, used to connect up to 50 LEDs in a <br />graphic display <br />FCB-1000 — Fire communication bridge, provides remote mounting <br />of the Ethernet connection <br />FIB-1000 — Fiber interface module, used to extend P-Link to multi - <br />mode fiber (2 required) <br />RLY-5 — Relay module, provides 5 form C relay contacts rated at 3.0 <br />amps 24VDC/125AC <br />SPG-1000 — Serial parallel gateway, allows for the connection to a <br />serial or parallel printer <br />The FIB-1000, FCB-1000 and the SPG-1000 may be installed in the <br />stacker bracket or ordered with the optional rack mount enclosure. <br />MC-1000 Multi -Connect allows up to sixty-three AFC series panels <br />to share a single reporting technology. <br />IDC-6 — Initiating device circuit provides 6 programmable inputs <br />AE-2 — Two card expansion cabinet <br />AE-8 — Eight card expansion cabinet <br />AE-14 — Fourteen card expansion cabinet <br />Ethernet/I.P. Connection <br />The AFC-100 is shipped standard with an Ethernet connection. <br />This connection is the programming port and may be connected <br />to a building Wide Area Network (WAN) or Local Area Network <br />(LAN). Once connected to the Internet, the panel may be selectively <br />programmed to e-mail alarm conditions, trouble conditions, <br />supervisory conditions, test, Event History and detector status. An <br />e-mail may be sent to the panel and the panel will e-mail the event <br />history, detector status, configuration file or server status to an <br />authorized E-mail account. In addition, reminders may be set to send <br />an e-mail for service, testing or other conditions. <br />In addition, the Ethernet connection is UL listed as an IP <br />communicator. The IP communicator is listed to report to the UL <br />listed Sur -Gard III IP receiver. The IP communicator replaces the <br />traditional less reliable alarm communicator transmitter that utilized <br />telephone lines. The IP communicator is an active method of <br />connection and communication to the monitoring station. <br />Potter Electric Signal Company, LLC St. Louis, MO Phone: 800-325-3936 www.pottersignal.com <br />8830134 - REV F • 2/22 PAGE 4 OF 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.