My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
>
Address Records
>
MERRILL CREEK PKY
>
2300
>
ZAP ENERGY
>
2300 MERRILL CREEK PKY ZAP ENERGY 2023-09-26
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/26/2023 2:53:14 PM
Creation date
8/24/2023 9:02:54 AM
Metadata
Fields
Template:
Address Document
Street Name
MERRILL CREEK PKY
Street Number
2300
Tenant Name
ZAP ENERGY
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
242
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
STRUCTURAL STEEL OBSERVATIONS REPORT MAYES I lrerracon <br />Report Number: M7231156.0002 <br />Service Date: 05/05/23 20225 Cedar Valley Rd Ste 110 <br />Report Date: 05/10/23 Lynnwood, WA 98036-6365 <br />425-742-9360 <br />Client Project <br />Zap Energy Inc Zap OPUS TI Steel Bridge and Stairs <br />Attn: 3ulie Yinger 2300 Merrill Creek Pkw <br />506 2nd Ave Ste 1400 Everett, WA <br />Seattle, WA 98104-2329 <br />Project Number: M7231156 <br />Permit No.: B2302-100 <br />General Information <br />Kelly with Trico requested Mayes Terracon be on site for high -strength bolting observation and welding observation. <br />Structural steel is being constructed by Evergreen Erectors. Arrived at 1330 and departed at 1500. <br />The construction documents referenced for this observation include Permit Set 02/17/23, Finnoe Design and Fabrication LLC <br />for Construction drawings 04/18/23. <br />High -Strength Bolting Observation <br />Installation Observation <br />Connection Elevation/Location Method of Referenced Bolt Faying Compliance <br />Type Tensioning Documents Grade Surfaces Status <br />Snug -tight Level 1 to 2, J.5-K.2/3.9-4.2 Snug -tight S3.1, S3.2, S3.3 A325 -- Complies <br />Bolt Storage: None Stored (Complies) Mill Certification: Not Required <br />Welding Observation <br />Welding was performed prior to arrival. Welding procedures could not be verified. Welder qualifications have been <br />reviewed. <br />Inspection <br />Elevation/Location <br />Connection Type <br />Type of <br />Referenced <br />Applicable <br />Compliance <br />Type <br />Weld <br />Documents <br />Code <br />Status <br />Final <br />Level 1 to 2 stair landing, J.5/3.9 <br />C-channel stringer to <br />Fillet, <br />G-G/E2 <br />AWS D1.1 <br />Complies <br />HSS beam <br />Flare -Bevel <br />Static <br />Final <br />Level 2, K/4.2 <br />Existing W-column <br />Fillet <br />Q-Q/E2 <br />AWS D1.1 <br />Complies <br />Static <br />Final <br />Level 1 to 2 stairs, Level 2 <br />Guard rail post to C- <br />Fillet <br />E1 <br />AWS D1.1 <br />Complies <br />platform, J.5-K.2/3.9-4.2 <br />channel <br />Static <br />Final <br />Level 1 to 2 stair landing and <br />Deck to supports <br />Puddle <br />S3.1 <br />AWS D1.1 <br />Complies <br />Level 2 platform, J.5-K.2/3.9-4.2 <br />Static <br />Additional Comments <br />Welding performed by Ryan C. Pakka, WABO Welder ID: W17343, (expiration 01/01/24). <br />The results of observation(s) for today were reported to Kelly with Trico. <br />Compliance Statement <br />Based on our observations, structural steel construction activities at the above -referenced locations appeared to be <br />completed in general accordance with the project plans and specifications. <br />Services: Special Inspections / Materials Testing <br />Mayes/Terracon Rep.: Carl Harrington <br />Reported To: Trico <br />Contractor: Evergreen Erectors <br />Report Distribution: <br />(1) Zap Energy Inc, Julie Yinger <br />(1) City of Everett WA, Cindy Bergsma <br />(1) City of Everett WA, Permit Services <br />(1) JPC Architects LLC, Anna Griffith Reviewed By: <br />(1) Mayes Testing Engineers, Inc, <br />(1) Mayes Testing Engineers, Inc, Mike <br />Donna Pollard <br />Mattox <br />(1) Zap Energy Inc, Steve Zwaller <br />Barry Tuttle <br />Project Field Manager <br />The tests were performed in general accordance with applicable ASTM, AASHTO, or DOT test methods. This report is exclusively for the use of the client indicated above <br />and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein are only applicable to the actual samples tested at <br />the location(s) referenced and are not necessarily indicative of the properties of other apparently similar or identical materials. <br />DM027, 04-29-22 Rev.5 Page 1 of 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.