Laserfiche WebLink
a • I. <br /> Enter project information in Console below for Interior Lighting(Alteration 50%or more Back to General Lighting Information <br /> Lighting Scope Type/Project Type Compliance Method: Calculation Adjustment 0 <br /> No Calculation Adjustments allowed loe V <br /> Interior Lighting/Alteration 50%or more - O Space By Space ®Building Area Verify Compliance Notifications <br /> Status COMPLIES BUILDING AREA, Last compliance check ran February 17,2023 • <br /> Interior Lighting Power Allowance- Building Area <br /> Add Building Area I(Select One) <br /> Gross Interior Total Watts Allowed Total Proposed Watts <br /> Building Area Area(SF) LPA(Watts/SF) (SF x LPA) By Building Area <br /> Office II 28,160 0.64 18.022 8,137 <br /> Proposed Lighting Power Density- Building Area <br /> Add Fixtures'(Select One) ...I <br /> ;Nide,Details <br /> Total Watts Proposed <br /> Quantity of Watts per Total Linear Watts per Linear (#F x WpF)or <br /> Fixture Category Fixture Type I Application Building Area Fixture ID N or E Fixtures(#F) Fixture(WpF) Feet(LF) Foot(WpLF) (LF x WpLF) <br /> Individual Fixtures 1713 Decorative Office F-4 New 3 29 87 <br /> Individual Fixtures r✓6 Decorative Office F-6 New 6 46 276 <br /> Individual Fixtures rift Horizontal surface-mount Office F-8 New 2 24 48 <br /> Individual Fixtures rd Y8 Troffer Office F-1 New 108 32 3,456 . <br /> Individual Fixtures rd'1$ Recessed downlight Office F-3 New 40 16 640 <br /> Individual Fixtures 17 a Suspended Office F-2 New 119 14 1,666 <br /> Individual Fixtures go d Suspended Office F-5 New 71 24 1,704 <br /> Individual Fixtures 2'19 Under-cabinet Office F-7 New 12 13 156 <br /> Individual Fixtures 2 6 Wall-mounted Office F-9 New 8 13 104 <br />