Laserfiche WebLink
1 Operation <br /> Changing the TSTAT Program <br /> This heater comes with three TSTAT programs built in. Each program is unique and allows you to modify your <br /> thermostat setting to your preference. The stove is shipped pre-programmed in TSTAT program 1. <br /> How to Tell Which TSTAT Program You Are In <br /> When the heater is placed in thermostat mode(TSTAT button pressed),the BLUE light will flash once,twice, or three <br /> times. This will let the operator know which thermostat program the heater in. One blue flash indicates thermostat <br /> program 1. Two blue flashes indicates program 2. Three blue flashes indicates program 3. <br /> Switching Between Program 1, 2, and 3 <br /> Each time you press the"STOP"and"TSTAT'button simultaneously while the unit is cold, the TSTAT program will <br /> toggle to the next program. Continue to press these two buttons until the blue Auto-Fan LED light flashes the <br /> program you wish to use. <br /> Thermostat Program 1 <br /> When the thermostat stops calling for heat(the thermostat is open)the thermostat"steps down"to a lower heat <br /> setting. The heater will stay at this setting for 15 minutes. If the thermostat does not call for heat,the thermostat will <br /> "step down"again to a lower setting (or off). At any time if the thermostat calls for heat (thermostat is closed)during <br /> this cycle,the heater will resume at the HEAT output setting set at the control board. <br /> If thermostat calls for heat If thermostat stops calling for heat(thermostat open) <br /> Heater Set at (thermostat closed) Heater goes to MEDIUM. If after 15 minutes <br /> Heater runs at setting set on thermostat still open, heater goes to MEDIUM-LOW. If <br /> HIGH control panel dial. after 15 minutes thermostat still open, heater goes to <br /> LOW. If after 15 minutes thermostat still open, heater <br /> turns off. <br /> Heater Set at If thermostat calls for heat If thermostat stops calling for heat(thermostat open) <br /> (thermostat closed) Heater goes to MEDIUM-LOW. If after 15 minutes <br /> MEDIUM Heater runs at setting set on thermostat still open, heater goes to LOW. If after 15 <br /> control panel dial. minutes thermostat still open, heater turns off. <br /> Heater Set at If thermostat calls for heat If thermostat stops calling for heat(thermostat open) <br /> (thermostat closed) Heater goes to LOW. If after 15 minutes thermostat <br /> MEDIUM-LOW Heater runs at setting set on still open, heater turns off. <br /> control panel dial. <br /> Heater Set at If thermostat calls for heat If thermostat stops calling for heat(thermostat open) <br /> (thermostat closed) Heater will run for 15 minutes. If thermostat still open, <br /> LOW Heater runs at setting set on heater turns off. <br /> control panel dial. <br /> NOTE: This program is not recommended for areas with little heating requirements(mild climates, small rooms, <br /> etc.). <br /> Thermostat Program 2 <br /> In Thermostat Mode Program 2 when the thermostat stops calling for heat(the thermostat is open)the following <br /> happens: <br /> • The burn rate decreases to Level 1 (low)for 15 minutes. If there is no call for heat during that time... <br /> • The unit turns off. <br /> If there is a call for heat by the thermostat(the thermostat is closed)at any point during this cool-down period then <br /> the burn rate resumes corresponding with the setting on the control panel. <br /> Thermostat Program 3 <br /> In Thermostat Mode Program 3 when the thermostat stops calling for heat(the thermostat is open)the following <br /> happens: <br /> • The burn rate decreases to Level 1 (low)and remains at this level until there is a call for heat by the thermostat(the <br /> thermostat is closed),then resumes corresponding with the setting on the control panel. <br /> ©Travis Industries 4070806 100-01191000 <br />