Laserfiche WebLink
Maintenance 41 <br /> Access and Clean Components <br /> The insert may be removed to inspect and access the components. Follow the directions below to <br /> remove the insert from the fireplace. <br /> /A DISCONNECT THE POWER CORD (OR DISABLE THE BREAKER)AND MAKE SURE THE <br /> HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) PRIOR TO CONDUCTING <br /> SERVICE. <br /> 1. Remove the surround panel (and control panel) and place aside. <br /> 2. Use the latch to disconnect the flue assembly from the insert. <br /> 3. Place protection on top of the hearth to protect it against scratches. <br /> 4. Slide the insert forward 4"to 12"to gain access to the components (if necessary). <br /> 5. Use a vacuum/compressed air to clean the internal components (cooling fan, auger motor, etc.). <br /> Clean the Exhaust Blower <br /> /A MAKE SURE THE HEATER HAS FULLY COOLED (APPROXIMATELY 45 MINUTES) BEFORE <br /> CONDUCTING SERVICE. <br /> /A THE ASHPAN MUST BE IN PLACE WHILE THE HEATER IS IN USE. <br /> 1. Remove the insert from the fireplace (see above). <br /> 2. Loosen the 8 screws holding the intake duct cover in place (11/32" nutdriver). Remove the intake <br /> duct cover by sliding it up and off the studs (the gasket will remain in place). <br /> ©Travis Industries 11/15/18- 1341 AGP Insert <br />