i Permit Inspections <br /> V E R E T T City of Everett <br /> WASHINGTON <br /> Permit Number: M2211-037 Description:AIR HANDLER AND HEAT PUMP INSTALL <br /> Applied: 11/10/2022 Approved: 11/10/2022 Site Address: 1520 81ST PL SE <br /> Issued: 11/11/2022 Finaled:8/30/2023 City,State Zip Code: EVERETT,WA 98203 <br /> Status: FINALED Applicant:CM AIR PROS LLC(CONST) <br /> Parent Permit: Owner:GRISWOLD VANIA&ANTHONY <br /> Parent Project: Contractor: CM AIR PROS LLC(CONST) <br /> Details: <br /> AIR HANDLER AND HEAT PUMP INSTALL <br /> SCHEDULED DATE COMPLETED DATE TYPE INSPECTOR RESULT REMARKS <br /> 2/24/2023 2/24/2023 MECH 06-FINAL JEFF M RHODE CORRECTION see notes <br /> REQUIRED <br /> Notes: <br /> 2/20/2023 2:47 PM CM AIR PROS LLC(CONST) <br /> please call on the way <br /> Contact Name:Anthony Griswold <br /> Site Address:1520 81ST PL SE <br /> Phone:2063800159 <br /> e-Mail:anthonyrgriswold@gmail.com <br /> -no emergency drain on condensate <br /> 307.2.3 Auxiliary and Secondary Drain Systems <br /> In addition to the requirements of Section 307.2.1,where damage to any building components could occur as a result of overflow from the equipment <br /> primary condensate removal system,one of the following auxiliary protection methods shall be provided for each cooling coil or fuel-fired appliance <br /> that produces condensate: <br /> An auxiliary drain pan with a separate drain shall be provided under the coils on which condensation will occur.The auxiliary pan drain shall discharge <br /> to a conspicuous point of disposal to alert occupants in the event of a stoppage of the primary drain.The pan shall have a minimum depth of 11/2 <br /> inches(38 mm),shall be not less than 3 inches(76 mm)larger than the unit,or the coil dimensions in width and length and shall be constructed of <br /> corrosion-resistant material.Galvanized sheet steel pans shall have a minimum thickness of not less than 0.0236 inch(0.6010 mm)(No.24 gage). <br /> Nonmetallic pans shall have a minimum thickness of not less than 0.0625 inch(1.6 mm). <br /> A separate overflow drain line shall be connected to the drain pan provided with the equipment.Such overflow drain shall discharge to a conspicuous <br /> point of disposal to alert occupants in the event of a stoppage of the primary drain.The overflow drain line shall connect to the drain pan at a higher <br /> level than the primary drain connection. <br /> An auxiliary drain pan without a separate drain line shall be provided under the coils on which condensate will occur.Such pan shall be equipped with a <br /> water-level detection device conforming to UL 508 that will shut off the equipment served prior to overflow of the pan.The auxiliary drain pan shall be <br /> constructed in accordance with Item 1 of this section. <br /> A water-level detection device conforming to UL 508 shall be provided that will shut off the equipment served in the event that the primary drain is <br /> blocked.The device shall be installed in the primary drain line,the overflow drain line,or in the equipment-supplied drain pan,located at a point higher <br /> than the primary drain line connection and below the overflow rim of such pan. <br /> I <br /> Printed:Wednesday, 30 August, 2023 1 of 2 <br /> SUPERION <br />