3407 GRAND AVE 2023 Plans 2023-08-31
>
Address Records
>
GRAND AVE
>
3407
>
Plans
>
3407 GRAND AVE 2023 Plans 2023-08-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2023 8:02:36 AM
Creation date
8/31/2023 8:02:24 AM
Metadata
Fields
Template:
Address Document
Street Name
GRAND AVE
Street Number
3407
Permit
B2305-081
Year
2023
Notes
KITCHEN & LIVING RM REMODEL REMOVE WALL, NEW BEAM & WINDOWS
Address Document Type
Plans
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FRAMING LUMBER CONT. <br /> 15. EXTERIOR STUD WALLS SHALL BE 2X6 ® 16" O.C.. UNLESS NOTED OTHERWISE. INTERIOR STUD BEARING WALLS SHALL BE <br /> CONSTRUCTED USING 2X4 0 16" O.C. AT UPPER TWO FLOORS AND EITHER 2X6 ® 16" O.C. OR 3X4 ® 16" O.C. BELOW TOP TWO FLOORS. <br /> STUD NONBEARING WALLS SHALL BE CONSTRUCTED USING 2X4 0 24" O.C.. UNLESS NOTED OTHERWISE. SEE NOTE 1 FOR LUMBER GRADES <br /> OF STUDS AND PLATES. <br /> 16. FRAMING ANCHORS FOR JOISTS, PURLINS AND POSTS SHALL BE SIMPSON, OR APPROVED EQUAL. APPROVAL MUST BE OBTAINED IN 4 <br /> WRITING PRIOR TO INSTALLATION. FILL ALL FASTENER HOLES WITH FASTENER TYPES (NAILS, BOLTS, ETC.), SIZES, AND QUANTITIES AS <br /> SPECIFIED BY THE MANUFACTURER. <br /> 17. ALL HEADERS SHALL BE 4X8 DF#2 UNLESS OTHERWISE NOTED ON THE DRAWINGS <br /> 18. OSB OF EQUAL OR GREATER THICKNESS MAY BE SUBSTITUTED FOR PLYWOOD USED IN SHEAR PANELS. <br /> a) <br /> 19. CONTACT THIS OFFICE PRIOR TO MAKING ANY CHANGES TO THESE DETAILS AND NOTES. +� <br /> 0 <br /> 20. BLOCKING SHALL BE PROVIDED AT ALL POINTS OF BEARING TO PREVENT ROTATION OF JOISTS AND BEAMS. 'V <br /> GENERAL <br /> 1. ALL MATERIALS AND WORKMANSHIP SHALL CONFORM TO THE CONTRACT DRAWINGS. Q a N o E <br /> o <br /> 2. DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE BUILDING. THE CONTRACTOR rn of t <br /> SHALL PROVIDE ADEQUATE SHORING, BRACING AND GUYS IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL SAFETY ORDINANCES. 0) Y a re <br /> ANY DEVIATION MUST BE APPROVED PRIOR TO ERECTION. — ()" <br /> .0 o:.r*Q <br /> 3. ALL ERECTION PROCEDURES SHALL CONFORM TO OSHA STANDARDS. ANY DEVIATION MUST BE APPROVED BY OSHA PRIOR TO 0 o lu tli <br /> z <br /> ERECTION. <br /> 4. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION PROCEDURES INCLUDING LAGGING, SHORING AND <br /> M W a 3 <br /> PROTECTION OF ADJACENT PROPERTY, STRUCTURES, STREETS AND UTILITIES IN ACCORDANCE WITH ALL NATIONAL, STATE AND LOCAL <br /> SAFETY ORDINANCES. 4•••' <br /> 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF ALL TRADES AND SHALL CHECK ALL DIMENSIONS. ALL <br /> DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER AND BE RESOLVED BEFORE PROCEEDING WITH THE WORK. <br /> 6. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT <br /> ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED SUBJECT TO REVIEW BY THE <br /> ENGINEER. 3 e <br /> 7. ALL DETAILS DESIGNATED AS STANDARD OR TYPICAL SHALL OCCUR IN ADDITION TO ANY OTHER SPECIFIC DETAIL CALLED OUT. ; 2 <br /> 8. COORDINATE WITH MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS FOR SIZE AND LOCATION OF ALL OPENINGS REQUIRED FOR <br /> DUCTS, PIPES, PIPE SLEEVES, ELECTRICAL CONDUITS, AND OTHER ITEMS TO BE EMBEDDED IN CONCRETE OR OTHERWISE INCORPORATED IN - <br /> STRUCTURAL WORK. o <br /> 9. PROVIDE OPENINGS AND SUPPORTS, AS REQUIRED PER STANDARD DETAILS FOR HEATERS, MECHANICAL EQUIPMENT, VENTS, DUCTS, c I <br /> PIPING, ETC. ALL SUSPENDED MECHANICAL EQUIPMENT SHALL BE SWAY OR LATERALLY BRACED. c I <br /> 10. ALL INFORMATION SHOWN ON THE DRAWINGS RELATIVE TO EXISTING CONDITIONS IS GIVEN AS THE BEST PRESENT KNOWLEDGE BUT z <br /> WITHOUT GUARANTEE OF ACCURACY. WHERE ACTUAL CONDITIONS CONFLICT WITH THE DRAWINGS, THEY SHALL BE REPORTED TO THE <br /> ENGINEER SO THAT THE PROPER REVISIONS MAY BE MADE. MODIFICATION TO DETAILS OF CONSTRUCTION SHALL NOT BE MADE WITHOUT <br /> PRIOR WRITTEN APPROVAL OF THE ENGINEER. <br /> 11. ARCHITECTURAL AND MECHANICAL PLANS ARE CONSIDERED A PART OF THE STRUCTURAL DESIGN DRAWINGS AND ARE TO BE USED TO <br /> DEFINE DETAIL CONFIGURATIONS INCLUDING; BUT NOT LIMITED TO RELATIVE LOCATION OF MEMBERS, ELEVATIONS, DIMENSIONS AND <br /> LOCATIONS OF ALL OPENINGS, ETC. t5 <br /> jo <br /> Warn <br /> ~tea <br /> 0W <br /> LL1J ,w <br /> U <br /> coVLyc <br /> ?Ar#1" <br /> FEB 09, 2023 <br /> Drawn By CRL <br /> Checked By. CCC <br /> Date: 02-08-2023 <br /> SDA JOB No. <br /> 9752 <br /> STRUCTURAL <br /> NOTES <br /> S—2.0 <br />